Responds to Requesting Review of RCIC Sys Automatic Restart Per TMI Action Item II.K.3.13.Acceptance Criteria Identified in Ltr Satisfied
ML20023C169
Person / Time
Site: Brunswick  
Issue date: 05/09/1983
From: Zimmerman S
CAROLINA POWER & LIGHT CO.
To: Vassallo D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.K.3.13, TASK-TM LAP-83-124, NUDOCS 8305120003
Download: ML20023C169 (1)


Text

_-.

8P&L SERIAL: LAP-83-124 Carolina Power & Light Company MAY 091983 1

Director of Nuclear Reactor Regulation Attention:

Mr. D. B. Vassallo, Chief Operating Reactors Branch No. 2 Division of Licensing United States Nuclear Regulatory Commission Washington, DC 20555 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 AND 50-324 LICENSE NOS. DPR-71 AND DPR-62 NUREG-0737 ITEM II.K.3 13 j

RCIC AUTOMATIC RESTART i

i

Dear Mr. Vassallo:

By letter dated March 16, 1983, you provide.d to Carolina Power &

Light Company (CP&L) the NRC staff's generic safety evaluation for reactor core isolation cooling (RCIC) system automatic restart (Enclosure 2) and the plant specific acceptance criteria for RCIC automatic estart (Enclosure 3).

As requested by your letter, CP&L has reviewed Enclosure 3 and verified that the acceptance criteria identified in that enclosure have been satisfied for the Brunswick Steam Electric Plant, Unit Nos. 1 and 2.

If you have any questions concerning this response, please contact our staff.

Yours very truly, S. R.

immerman Manager Licensing & Permits WRM/cfr (6701WRM) cc:

Mr. D. O. Myers (NRC-BSEP) 4 Mr. J. P. O'Reilly (NRC-RII)

Mr. S. D. MacKay (NRC)

G305120003 830509 PDR ADOCK 05000324 P

PDR