BEFORE THE UNITED. STATES NUCLEAR REGULATORY COMMISSION In the Matter of Docket Nos. 50-277 PHILADELPHIA ELECTRIC COMPANY 50-278 APPLICATION FOR AMENDMENT OF FACILITY OPERATING LICENSES DPR-44 & DPR-56 Edward G. Bauer, Jr.
Eugene J. Bradley 2301 Market Street Philadelphia, Pennsylvania 19101 Attorneys for Philadelphia Electric Company W
-8210200063-f i
BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION In the Matter of Docket Nos. 50-277 PHILADELPHIA ELECTRIC COMPANY 50-278 APPLICATION FOR AMENDMENT OF FACILITY OPERATING LICENSES DPR-44,& DPR-56 Philadelphia Electric Company, Licensee under Facility Operating Licenses DPR-44 and DPR-56 for Peach Bottom Units 2 and 3, hereby reauests that the Technical Specifications incorporated in Appendix A of the Operating Licenses be amended to reflect modifications required to meet the criteria of Appendix A of NUREG 0661, " Mark I Containment Long Term Program" by revising certain sections as indicated by a vertical bar in the margin of the attached pages 77, 78, 86, and 190.
l The proposed amendment revises the operability and surveillance requirements on pages 77, 78 and 86 to reflect a
t planned modification to the' suppression pool temperature monitoring system.
The modification will replace the existing temperature-monitoring system with redundant suppression pool' monitoring systems that meet the criteria of NUREG 0661.
Each new monitoring system will consist of thirteen (13) resistance i
temperature detectors mounted-in thermowells installed in the torus-shell.below the minimum water level required by the Technical Specifications, a processor / indicator / printer lo._ted in the control room, and a recorder located in the control room.
j Annunciation will be provided for-high temperature and signal 4
failure.
The equipment will satisfy the Category I design recommendations of' Regulatory Guide 1.97, Revision 2,
[
" Instrumentation for Light-Water-Cooled Nuclear Power Plants to
~i=
Access Plant and Environs Conditions During and Following an Accident."
The amendment proposes a testing frequency of once per day and once per operating cycle for the instrument check and sensor calibration,.respectively.
The proposed-testing frequency i
is consistent with the guidance provided in-the " Standard
. Technical Specifications for General Electric Boiling. Water 4
[
Reactors", NUREG-0123, Revision.3, page 3-74. ' Malfunction detection circuits provide additional assurance that. accurate temperature _information is presented to the operator.
The detection circuit continuously monitors the individual
' temperature inputs.for out of range or' intermittent signals,
- provides for annunication and, upon operator action, removal of a I
i
~
.2
failed-signal.
Further,-due to the proximity of redundant
. sensors to each other, the instrument check will provide early indication of any drift in calibration associated with an
. individual sensor.
Additionally, the proposed amendment-revises the pressure and temperature limits on page 165 to conform with the i-l NRC criteria identified in NUREG-0661, " Safety Evaluation Report, Mark I. Containment Long-Term Program".
The proposed i
specification would require an external visual examination of the suppression chamber whenever-the local pool temperature exceeds 200 F coincident with relief valve operation.
The new limits reflect the completed modification _of the Safety Relief Valve discharge to incorporate the T-quencher design on both Peach Bottom. Unit 2 and Unit 3.
Further, the proposed amendment deletes obsolete I
specifications and footnotes on page 86 for Peach Bottom Unit No.
i 3 since the modifications authorized by Amendment No. 67 are 4
complete.
Several changes are proposed in section 3.7.A.l.c
-(page 165a) in the interest of clarification.
i Pursuant to 10 CFR Section-170.22 " Schedule of Fees for
' Facility License Amendments", Philadelphia-Electric Company t
f proposes that:this_ Application for Amendment be considered a l
~
~ Class-III Amendment for Unit'2'and a Class I Amendment for Unit 3, since_the proposed changes do not involve a significant 2 hazards consideration.
'3
,-,~..r-----..
~~,,--yu.
~~-w e-i--
7 v.-~~
,.-~r
The Plant. Operating Review Committee and the Operation and Safety Review Committee have reviewed these proposed changes to the: Technical Specifications, and have concluded that they do not involve an unreviewed safety question or a significant hazard consideration; and will not endanger the health and safety of the public.
Respectfully submitted, PHILADELPHIA ELECTRIC COMPANY By A
g{ w/
' Wice ' P(esident /J i
e L
COMMONWEALTH OF-PENNSYLVANIA ss.
COUNTY OF PHILADELPHIA S. L. Daltroff, being first duly sworn, deposes and says:
J That he is Vice President of Philadelphia Electric Company, the Applicant herein; that he has read the foregoing Application for-Amendment of Facility Operating Licenses and knows-the contents thereof; and that the statements and matters set forth therein are true.and correct to the best of his knowledge, information and belief.
g K
V d
()
Subscribed and sworn to before me this /JN day-hW lV 8 Y of Siif Q
-Notary Public uj ri PATmCIA D. SCHOLL r
Notary PubFe, Philadelphia, Phi $dciphia Co.
IIy CecnIinssion,fspirtiTsbruary 10.1986
$e e
i ;v
%.,; y.
3 w
w -
e m
.ri
,----g y
e--
.~
CERTIFICATE OF SERVICE I certify that service of the fortgoing Application was made upon the Board of Supervisors, Peach Bottom Township, York 1
County, Pennsylvania, by mailing a copy thereof, via first-class mail, to' Albert R. Steele, Chairman of the Board of Supervisors, R.D. No. 1, Delta, Pennsylvania 17314; upon the Board of Supervisors, Fulton Township, Lancaster County, Pennsylvania, by mailing a copy thereof, via first-class mail, to George K.
Brinton, Chairman of-the Board of Supervisors, Peach Bottom, Pennsylvania 17563; and upon the Board of Supervisors, Drumore Township, Lancaster County, Pennsylvania, by mailing a copy thereof, via first-class mail, to Wilmer P. Bolton, Chairman of the Board of Supervisors, R.D. No. 1, Holtwood, Pennsylvania 17532; all this 15th day of-October 1982.
a
.W-
/ b/
4 Eugene J. Bradley Attorney for-Philadelphia Electric Company.
y s-et-e y
t'wi pm-7~
re y y m gr f-4+W-
?Y-F T
- -"d'Lpf V*