Advises That 890220 & 900226 Responses to Generic Ltr 88-14, Instrument Air Supply Sys Problems Affecting Safety-Related Equipment Acceptable
ML20012E996
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 04/03/1990
From: Masciantonio A
Office of Nuclear Reactor Regulation
To: Berry K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
GL-88-14, TAC-71628, NUDOCS 9004090273
Download: ML20012E996 (3)


Text

pp- --

r r

p April 3,1990 J

Docket No. 50-155 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, MicMgan 49201

Dear Mr. Berry:

SUBJECT:

BIG ROCK POINT PLANT - INSTRUMENT AIR SUPPLY SYSTEM PROBLEMS AFFECTING SAFETY-R' LATED EQUIPMENT (GENERIC LETTER 88-14) d TAC NO. 71628 By letter dated February 20, 1989, Consumers Power Company responded to Generic Letter 88-14 (Instrument Air).

Based on a review of your response, the staff requested additional information in letter dated November 21, 1989.

The additional information was provided in your letter dated February 26, 1990.

In your responses, you indicated Big Rock Point compliance with the recommenda-tions in Generic Letter 88-14; however, completion of some actions extends i

beyond the schedule established in the Generic Letter.

The justification and alternative schedule provided are acceptable to the staff.

If subsequent I

' inspection identifies deficiencies in your program, this issue will be reopened.

Presently, we consider this action complete.

Sincerely, h

l Original signed by l

l Armand S. Masciantonio, Project Manager l

Project Directorate 111-1 Divi sion of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation cc:

See next page DISTRIBUTION DOCKth FILEe>

PSHUTTLEWORTH NRC & LOCAL PDRS WLEFAVE i

l PD31 R/F.

GEDISON I

JZWOLINSKI ACRS((10) l EJORDAN OGC

]

BGRIMES AMASCIANTONIO LA/PD31:DRS PM/PD RSP

(

31:DRSP 0

PSHUTTLEWOR AMASCIANTONIO J

g /90 3 /30/90 4/)/90

\\

f0[30$ck200$0f55 BIG ROCK GL88-14 TAC 71268 p

PDC i

a

,i.'

  1. 'y rns Eu,o,{

UNIT E D ST ATES j' '

,f '

NUCLEAR REGULATORY COMMISSION i

WA$mNGToN, D. C 20%b

% l,] #"

April 3,1990 Docket No. 50-155 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201 l

Dear Mr. Berry:

i

SUBJECT:

BIG ROCK POINT PLANT - INSTRUMENT AIR SUPPLY SYSTEM PROBLEMS AFFECTING SAFETY-RELATED EQUIPMENT (GENERIC LETTER 88-14)

TAC NO. 71628

?

By letter dated February 20, 1989, Consumers Power Company responded to Generic Letter 88-14 (Instrument Air).

Based on a' review of your response, the staff requested additional information in letter dated November 21, 1989.

The additional information was provided in your letter dated February 26, 1990.

In your responses, you indicated Big Rock Point compliance with the.recommenda-tions in Generic Letter 88-14; however, completion of some actions extends beyond the schedule established in the Generic letter.

Thejustificationand alternative schedule provided are acceptable to_the staff.

If subsequent inspection identifies deficiencies in your program, this issue will be reopened.

Presently, we consider this action complete.

Sincerely, I. AMA Armand S. Masciantonio, Project Manager Project Directorate 111-1 1

Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation CC:

I See next page i

t l

l l

i

.L l

y-a

, o i

' Mr.4 Kenneth W, Berry Consun,ers Power Company Big Rock foint, Plant cc:

Mr. Thomas A. kcNish, Secret.ary C w.itniers Power Company I'd West Michigan Avenue Ja'.kson, Michigan '49201

(

JoM L. bacon. Esopire Consun,ers Power Company 212 West Michigan Avenue i

Jackson, Michigan 49201 P

Mr. William L. Beckman r e

l Plant Manager Bi Rock Point Plant 10 69 U.S. 31 North Charlevoix, Michigan 49720

[

Jane E. Brannon, County Clerk County Building Charlevoix, Michigan 49720 l

Office of the Governor Rotm 1 - Capitol Building Lansing, M 4higan 48913 u

i Re ional Administrator, Region III U.. Nuclear Regulatory Commission 799 Roosevelt Road l

Glen Ellyn, Illinois 60137 Nuclear racilities and Environmental Monitoring Section Office Division of Radiological Health i

P. O. Box 3003b Lansing, Michigen 48909 i

U.S. Nuclear Degu14 tory Commission i

Resident Inspector Office Big Rock Point hant 10253 U.$. 31 North i

i Charlevoix, Michigan 49720 i

l I

i__...I I