J

%.R g

)

. Duke Ibuw Company '

Hu II Take

'~

PO Bar33198 +

1' ice President

'. - Chiviotte, NC 28212 Nuclear Production (l

(TM)373-4531 j

' DUKE POWER Msrch 19.-1990-

-U.S.LNuclear Regulatory Commission

-ATTN Document Control Desk Washington, D.;C.

20555 Subjects : McGuire Nuclear Station,. Units - 1 and 2

. Docket Nos. 50-369 and 50-370 Supplement to Proposed Technical Specification Amendment to Allow the Use of.the Babcock & Wilcox (B&W) Kinetic Sleeving Process for Steam Generator Tube Repair Gentlement This letter supplements the proposed' Technical Specification amendment for McGuire Nuclear Station, which would allow the use of the B&W steam

. generator tube repair process described in Topical Report BAW-2045(P)-A -

that was submitted =to the staff by my letter dated February 15, 1990.- This supplement provides n' clarification to my original ~ submittal to satisfy an-NRC requirement described in section 4.0 of the NRC staff's Safety

~

-Evaluation Report for Topical Report BAW-2045(P)-A.

The attachment provides the clarification in the Bases section found-in-

. Attachment No'. 2 of my original submittal.

Pursuant to 10CFR50.91(b)(1), a copy of this supplement to our. amendment-1 request has been provided to the appropriate North Carolina official.

.Very truly yours, a

st" Hal B. Tucker Attachments SEL526 4

i

  • I L 9003280222 900319

(\\

-PDR ADOCK 05000369 y'

.P:

PDC e

OI D

ye: ~- ;.

v=

' r, r

  • f 4

p 4

L

.. U.S. Nuclear Regulatory Commission j

-ATTN ; Document Control Desk-i.

-March 19.-:1990.

p Page 2l xc: W/All. Attachments Mr. S.D. Ebneter, Administrator U. S. Nuclear Regulatory Commission, Region 11 101 Marietta Street, NW, Suite 2900 y.

Atlanta, Georgia ~30323 L

Mr. Dayne Brown,' Chief Radiation Protection Branch, Division of Facility Services-('

701 Barbour Drive Department of Human Resources.

Raleigh, N.C.

.27603-2008 Mr. ~ D.S. Hood.. Project Manager l

Office of Nuclear Reactor Regulation USNRC Washington, D.C.

20555

. Mr. P.K.' Van Doorn Senior Resident Inspector, USNRC.

McGuire Nuclear Station M&M Nuclear Consultants 1221 Avenue of the Americas New York, New York 10020 American Nuclear Insurers c/o Dottie Sherman, ANI Library 270 Farmington Avenue Farmington, CT 06032 L

~INPO Records Center l

Suite 1500 1100 circic 75 Parkway Atlanta, Georgia 30339

?,?

-!* I +

' -U.S. Nuclear Regulatory Commission-ATTN: Document Control Desk-r March.19, 1990 j:

Attachment F

lDuke Power Company

'1 McGuire Nuclear Station r

Supplement to Attachment No. 2, of Mr. Hal B.-Tucker's letter to U.S'.

g Nuclear Regulatory Commission dated February 15, 1990 Requesting a Revision

=i to Technical Specification ~4.4.5.4 NOTE: Vertical lines in the right side margin of the page indicate changes.

'l

.