ML20012C771
| ML20012C771 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 03/19/1990 |
| From: | Hayes J Office of Nuclear Reactor Regulation |
| To: | Bradham O SOUTH CAROLINA ELECTRIC & GAS CO. |
| References | |
| GL-89-21, NUDOCS 9003230197 | |
| Download: ML20012C771 (6) | |
Text
4
,p
)'.
s1 a
1.j; *.
j March 19, 1990 a
s Dockef No. 50-395 2
Mr. 0.S. Bradham
(
Vice President, Nuclear Operations 1
. South-Carolina Electric & Gas Co.
Virgil C. Sumer Nuclear Station P.O. Box 88(MailCode601) i Jenkinsville, South Carolina 29065
Dear Mr. Bradham:
SUBJECT:
UNIMPLEMENTED UNRESOLVED SAFETY ISSUES AT Y.C. SUMMER NUCLEAR STATION, UNIT NO. 1 On October 19, 1989, the staff issued Generic Letter (GL) 09-21 which requested information concerning the status of implementation of unresolved safety. issues (USI) et your facility.
Based on your response to this GL, dated i
November 22, 1989, our review of Agency records and discussions between your staff and the NRC Project Manager, the NRC staff has compiled the enclosed list representing our assessment of USI implementation. These results were presented to the Comission at a meeting on February 14, 1990. to this letter presents the staff's understanding of the current
+
status of all unimplemented USI for the V.C. Sumer Nuclear Station, Unit No.1.
The staff encourages your effort to complete the unimplemented USI.
If you have questions or coments about the enclosed information please contact your NRC Project Manager.
Sincerely, Original Signed By:
John J. Hayes, Jr., Project fianager Project Directorate 11 1 9
j@@jfj,g Division of Reactor Projects - 1/II P
P gl Office of Nuclear Reactor Regulation PDC
Enclosure:
As stated cc w/ enclosure:
See next page n
DISTRIBUTION Mocm=me e NRC PDR Local PDR S. Varga 14-E-4 G. Lainas 14-H-3 E. Adensam 14-B-20 P. Anderson 14-B.20 J. Hayes 14-B-20 0GC=
15-B-18 E. Jordan MNBB-3302 ACRS(10)
P-315 Summer File K. Eccleston S
OFC :LA:P g
- {MJDl-1J._...,D:PD
-1 7
_ p..
..... :.....t...... :.K_...s : sw IAME : Pant g3
- J E
sam J
DATE:3/M/90
- 3//f/90
/:3/jj/90 5
n 0FFICIAL RECORD COPY 0f -
.p[Q\\
Document Name:
4 o
i
'r. O. S. Bradham i
M South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station CC:
'I Mr. R. V. Tanner i
Executive Vice President i
S.C. Public Service Authority P. O. Box 398)
Moncks Corner South Carolina 29461-0398 l
J. B. Knotts, Jr., Esq.
Bishop Cook, Purcell and Reynolds 1400 L Street, N.W.
Washington, D. C. -20005-3502 Resident Inspector /Suomer NPS c/o U.S. Nuclear Regulatory Commission Route 1, Box 64 Jenkinsville, South Carolina 29065 Regional Adininistrator, Region II U.S. Nuclear Regulatory Conmission, 101-Marietta Street, N.W., Suite 2900 At1cnta, Georgia 30323 Chairman, Fairfield County Council P. O. Box 293 Winnsboro, South Carolina 29180 Mr. Heyward G. Shealy, Chief Cureau of Radiological Health South Carolina Department of Health and Environnental Control 2600 Bull Street Columbia, South Carolina 29201 South Carolina Electric & Cas Company Mr. A. R. Koon, Jr., Manager Nuclear Licensing Virgil C. Sumer lticlear Station P. O. Box 88 Jenkinsville, South Carolina 29 065
-l l
)
l
ENCLOSURE 1 CURRENT STATUS OF USIs FOR THE V.C. SUMMER NUCLEAR STATION '
]
l.
j Estimated l
1 Implemented USI TITLE Date Remarks
- i
(
A-44 Station Blackout 3/31/93 Staff issuance of
.SER anticipated:to
-be 3/31/91. Allows l
licensee two years for implementation A-47 Safety Implication of TBD-New Requirement; Control Systems in LWR Response due by Nuclear Power Plants 03/31/90.
1
/
l i
l
e lg March 19, 1990 Docket No. 50 395 Mr. 0.S. Bradham Vice President, Nuclear Operations South Carolina Electric & Gas Co.
Virgil C. Sumer Nuclear Station P.O. Box 88(MailCode601)
Jenkinsville, South Carolina 29065
Dear Mr. Bradham:
SUBJECT:
UNIMPLEMENTED UNRESOLVED SAFETY ISSUES AT V.C. SUMMER NUCLEAR STATION, UNIT NO. 1 On October 19, 1989, thestaffissuedGenericLetter(GL)89-21whichrequested information concerning the status of implementation of unresolved safety issues (USI) at your facility.
Based on your response to this GL, dated November 22, 1989, our review of Agency records and discussions between your staff and the NRC Project Manager, the NRC staff has compiled the enclosed.
list representing our assessment of USI implementation. These results were i
i presented to the Comission at a meeting on February 14, 1990.
, to this letter presents the staff's understanding of the current status of all unimplemented USI for the V.C. Sumer Nuclear Station, Unit No.1.
The staff encourages your effort to complete the unimplemented USI.
If you have questions or coments about the enclosed information please contact your NRC Project Manager.
Sincerely.
Original Signed By:
John J. Hayes, Jr., Project fianager Project Directorate 11-1 Division of Reactor Projects. I/II Office of Nuclear Reactor Regulation.
Enclosure:
As stated cc w/ enclosure:
See next page l
DISTRIBUTION l
Docket File NRC PDR Local PDR S. Varga 14.E-4 G. Lainas 14-H-3 E. Adensam 14-B-20 P. Anderson 14.B-20 J. Hayes 14-B-20 OGC 15-B_18 E. Jordan MNBB-3302 ACRS(10)
P-315 Summer File K. Eccleston
'0FC : LA:,PDt ig
-1
- D:PD
-1
....:g:qD
...... :.... f.,.g Lt!AME :PAnte g
- Jiff..ds:sw AE '
sam
- DATE:3//b/90
- 3//f/90
- 3/l /90 OFFICIAL RECORD COPY Document Name:
e c;
A e
Mr. O. S. Bradham l
South Carolina Electric & Gas Company-Virgil C. Summer 10 clear Station cc:
l Mr. R. V. Tanner Executive Vice President l.
S.C. Public Service Authority P. O. Box 398)
Moncks Corner, South Carolina 29461-0398 l
J. B. Knotts, Jr., Esq.
l Bishop, Cook,: Purcell and Reynolds l-L 1400 L Street, N.W.
Washington, D. C.
20005-3502 Resident Inspector /Sunrner NPS
[
c/o U.S. Nuclear Regulatory Commission Route 1, Box C4 Jenkinsville, South Carolina 29065 Regional Administrator, Region II U.S. Nuclear Regulatory Conmission, 101. Marietta Street, N.W., Suite 2900 Aticnta, Georgia 30323 Chairman, Fairfield County Cour.c ?1 i
P. O. Box 293 Winnsboro, South Carolina 29180
+
Mr. Heyward G. Shealy, Chief Bureau of Radiological Health 1
South Carolina Department of Health and Environnental Control 1
2600 Cull Street Columbia, South Carolina 29201 South Carolina Electric & Gas Company Mr. A. R. Koon, Jr., Manager Nuclear Licensing Virgil C. Sumer fOclear Station P. 0. Box 88 Jenkinsville, South Carolina 29 065
--r,
i i-ENCLOSURE 1 CURRENT-STATUS OF USIs FOR THE V.C. SUMMER NUCLEAR STATION i
Estimated Implemented USI TITLE Date Remarks A-44 Station Blackout 3/31/93 Staff issuance of SER anticipated to be 3/31/91. Allows licensee two years i
for implementation A-47 Safety Implication of TBD New Requirement.
Control Systems in LWR Response due hy Nuclear Power Plants
' 03/31/90.
h 1
Y l
i i
.y y
7 me-w w w w'
"- -'+