ML20012C005

From kanterella
Jump to navigation Jump to search
Forwards Current Status of Unimplemented USIs for Facility,Per Generic Ltr 89-21,including USI A-9 Re ATWS, USI A-44 Re Station Blackout,Usi A-46 Re Seismic Qualification of Equipment & USI A-47
ML20012C005
Person / Time
Site: Crane 
Issue date: 03/12/1990
From: Hernan R
Office of Nuclear Reactor Regulation
To: Hukill H
GENERAL PUBLIC UTILITIES CORP.
References
REF-GTECI-A-09, REF-GTECI-A-44, REF-GTECI-A-46, REF-GTECI-A-47, REF-GTECI-EL, REF-GTECI-SC, REF-GTECI-SY, TASK-A-09, TASK-A-44, TASK-A-46, TASK-A-47, TASK-A-9, TASK-OR GL-89-21, NUDOCS 9003190315
Download: ML20012C005 (3)


Text

P March 12, 1990 S

- y, Docket No. 50 289 E

Mr. Henry D. Hukill, Vice President

'and Director - TMI.1 GPU Nuclear Corporation P. O. Box 480 Middletown,' Pennsylvania 17057

Dear Mr. Hukill:

SUBJECT:

UNIMPLEMENTED UNRESOLVED SAFETY ISSUES AT THREE MILE ISLAND UNIT 1

-On October 19, 1989 thestaffissuedGenericLetter(GL)89-21whichrequested information concerning the status of implementation of. Unresolved Safety Issues-(USIs) at your facility.- Based.on your response to this GL, dated November 27, 1989, our review of Agency records and discussions between your staff and the NRC Project Manager, the NRC staff has compiled the enclosed list representing our assessment of USI implementation. These results were presented to the Comission at a meeting on February 14, 1990. to this letter presents the staff understanding of the current

' status'of all unimplemented USIs for the Three Mile Island-Unit 1.

The staff

- encourages your effort to complete the unimplemented USIs.

If_you have questions or comments about the enclosed information please contact me.

Sincerely, signed by A. Dromerick for Ronald W. Hernan,-Senior Project ~ Manager Project Directorate I.4 Division'of Reactor Projects-I/II Office of Nuclear Reactor Regulation DLSTR BUTION.

8%susty3%f Plant File

Enclosure:

NRC & Local PDRs S.Varga(14E4).

As stated B.Boger(14A2)

S.Norris OGC ACRS(10) cc'w/ enclosure:

E. Jordan (MNBB3302)

See next page R.Hernan K.Eccleston 0FC _:LA:FDI-4

PM DI-
PD:PDI-4 1

g..... :..g....... _j./

( N$E _.:SNMrls rc :JS

......:............:............:........__m.:..........__:............:............:.........

pTEj:3 //q/90 -

j //g/90
3/[L/90

'0FFICIAL RECORD COPY Document Name: SAFETY ISSUES AT TMll 9003190315 900312 h

PDR ADOCK 05000289 P

W PDC

f.

^~

L'

.(

Mr. Henry D. Hukill Three Mile Island Nuclear Station, 4-GPU Nuclear Corporation Unit No. 1 o

e cc:

G. Broughton Francis I. Young O&M Director, THI-1 Senior Resident Inspector (TMI-1) i GPU Nuclear Corporation U.S.N.R.C..

-Post Office Box 480 Post Office Box 311 Middletown,_ Pennsylvania 17057 Middletown, Pennsylvania 17057 Rir. bard J. McGoey Manager, PWR Licensing Regional Administrator, Region I GPU Nuclear Corporation U.S. Nuclear Regulatory Commission 100 Interpace Parkway 475 Allendale Road Parsippany, New Jersey 07054 King of Prussia, Pennsylvania 19406 C. W. Sigyth Robert B. Borsum TMI-1 Licensing Manager Babcock & Wilcox GPU Nuclear Corporation ~

Nuclear Power Generation Division Post Office Box 480 Suite 525 Middletown, Pennsylvania 17057 1700 Rockville Pike Rockville, Maryland 20852 Ernest L. Blake, Jr., Esq.

Shaw, Pittman, Potts & Trowbridge Governor's Office of State Planning and Development 2300 N Street, N.W.

ATTN: Coordinator, Pennsylvania Washington, D.C.

20037 State Clearinghouse Post-Office Box 1323 Harrisburg, Pennsylvania 17120 L

Sally S.!Klein, Chairperson

' Thomas H. Gerusky, Director Dauphin County Commissioner Bureau of Radiation Protection o

Dauphin County Courthouse Pennsylvania Department of-Front and Market Streets Environmental. Resources

, Harrisburg, Pennsylvania 17120 Post Office Box 2063 Harrisburg, Pennsylvania 17120-L Kenneth E. Witmer, Chairman Board of Supervisors of Londonderry Township 25 Roslyn Road Eilzabethtown, PA 17022 l

i 8

l l

l l

h

" p..'

ENCLOSURE 1 List of Incomplete USIs Expected Implemented USI#

TITLE Date Remarks A-9 Anticipated Transients 12/31/91 Design in progress.

Without Scram (ATWS) per Installation during 10 CFR 50.62 9R cutage A-4A Station Blackout.

1?/31/91 SER issued on 12/18/89.

1 Installation during i

9R outage.

-A-46' Seismic Qualification of 12/31/93 Awaiting supple-Equipment in Operating mental SER and Plants SQUG guidance.

A-47 Safety Implication of TBD New Requirement.

Control Systems in LWR Response due.by Nuclear Power Plants 03/31/90.

3 0

-