ML20012B371
| ML20012B371 | |
| Person / Time | |
|---|---|
| Site: | Yankee Rowe |
| Issue date: | 03/06/1990 |
| From: | Sears P Office of Nuclear Reactor Regulation |
| To: | Papanic G YANKEE ATOMIC ELECTRIC CO. |
| References | |
| REF-GTECI-A-11, REF-GTECI-A-44, REF-GTECI-A-46, REF-GTECI-A-47, REF-GTECI-EL, REF-GTECI-RV, REF-GTECI-SC, REF-GTECI-SY, TASK-A-11, TASK-A-44, TASK-A-46, TASK-A-47, TASK-OR GL-89-21, NUDOCS 9003140281 | |
| Download: ML20012B371 (3) | |
Text
c.
mj 3
j] / ]1 1
Ap~
March 6, 1990
- DocietNo.50029-
~
,Mr.-George Papanic, Jr.
y N Senior Project Engineer. Licensing i c A Yankee Atomic Electric Company
.h 580 Main Street:
M.ur -,Bolton,' Massachusetts 01740-1398 r J,.
f ear 1Mr.'Papanic:
D t
7d SUBJECTi UNIMPLEMENTED UNRESOLVED SAFETY ISSUES AT YANKEE R0WE i
m m -; H _10nL0ctober 19',1989 the staff issued Generic Letter (GL) 89-21 which requested. '
iinformation concerning the status of implementation of unresolved safety issues-j1,j#
x(USIs)-at*your facility. Based on your response to this GL, dated November 22,4 4.
1989,' our, review of Agency records and discussions between your staff and.thei D " T " our assessment of USI implementation.NRC Project Manager, the NRC staff has compile These'results were presented to the
+
y jf,
Commission at a meeting on' February 14, 1990.
'. Enclosure 1 to:this letter presents the staff understhnding of the current statusi
~
of all. unimplemented USIs for the Yankee Nuclear Power Station (Rowe). The, staff encourages your effort to complete the unimplemented USIs.
nn 4.lf.you have questions or comments about the enclosed information please contact
'your NRC Project. Manager.
Sincerely, Original Signed By:
Patrick M.-. Sears, Project Manager Project Directorate 1 3 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation
Enclosure:
As stated-
- cc w/ enclosure
'See next page DISTRIBUTION: Deche C FJ1e, NRC& Local PDRs, PDI.3 r/f, SVarga, BBoger, MRushbrook, PSears, RWessman pGC(for info.), EJordan, ACRS(10), RWessman MA4 -
D FC :PDI. /L q J37PM
- PDP3/[1R.
.c 4,.:............:............:............:.........
Tb
- PSears:mw.
- RWessdd HAME2:MRu.
i
- ............:.......,L....:...........:............:............:.........
DATE;;3/(/90.
- 3/L/90-
- 3/b /90 OFFICIAL RECORD COPY
/!
g f
k 9003140281 900306 v
.q PDR ADOCK 05000029 v-y' p
PNU
+
W:
p; s
- . s x9 M..
' Mr. George Papanic,- Jr.
(
p F
0 s
p cc w/ enclosures:
E
'Dr. Andrew C. Kadek, President
~and Chief Operating Officer
. Yankee Atomic Electric Company 580 Main Street
.Bolton, Macsachusetts 01740-1398 i-Thomas Dignan, Esquire-
' Ropes and Gray a
225: Franklin Street
- Boston, Massachusetts 02110 Mr. T. K.. Henderson Acting Plant Superintendent Yankee Atomic Electric Company Star' Route Rowe, Massachusetts '01367 Resident; Inspector -
-Yankee Nuclear Power Station U.S. Nuclear Regulatory Commission Post 0ffice Box 28 Monroe Bridge, Massachusetts 01350 Regional Administrator, Region I U.S. Nuclear Regulatory Conmission 475 Allendale Road King of. Prussia, Pennsylvania 19406 i
Robert M. Hallisey, Director Radiation Control Program Massachusetts Department of Public Health 150 Tremont-Street. 7th Floor Boston,tiassachusetts 02111' Mr. George Ster:inger
.Consissioner Vermont Department of.Public Service 120 State Street. 3rd Floor Montpelier, Vermont 05602' I~,
1-e
w
- Q ENCLOSURE c
)
Expected Implemention-051
-TITI.E Date Remarks 1
A Reactor Vessel Materials 06/30/91 To be reevaluated Toughness A-44 Station Blackout 12/31/92 SER projected-12/31/90 A-46 Seismic Qualification of 12/31/93 Requirements under Equipment in Operating development Plants A-47 Saftty implication of 03/31/90 New requirements Control Systems in th!R Nuclear Power Plants s
4 l
l l:
l l~
1 2
.-