ML20012A406

From kanterella
Jump to navigation Jump to search
Whole Body Exposure for CY89
ML20012A406
Person / Time
Site: Crystal River 
Issue date: 12/31/1989
From:
FLORIDA POWER CORP.
To:
Shared Package
ML20012A405 List:
References
NUDOCS 9003090455
Download: ML20012A406 (5)


Text

p-H..>

1 V**/

'\\,

n-

+.

WHOLE BODY EEPOSURE FOR CALENDAR YEAR 1989 x

Licensee' Reporting (Name and-Address)

NRC license No(s).

FLORIDA POWER CORPORATION DPR-72 CRYSTAL RIVER UNIT 3 P.O.

BOX 219-CRYSTAL RIVER,= FLORIDA' 32629 e ===-

If personnel monitoring was not required to be provided to any individual during the year, checking this box will-constitute a negative report indicating that such

. personnel monitoring was.not required.

OTHERWISE, COMPLETE THE FOLLOWING TABLE:

Estimated Annual-Whole Body' Number of Individuals Excosure Rances * (Rems) in Each Ranae No Measurable Exposure...................

890 Less Than 0.100.........................

360 0.100 - 0.250...........................

249 0.250 - 0.500.................-..........

159 0.500 - 0.750............................

52 l

^

0.750 --1.000............................

22' L

1.000 - 2.000............................

34 2.000 - 3.000.............................

4 3.000 - 4.000.............................

0 u

4.000 - 5.000.............................

0 5.000 - 6.000.............................

0 6.000 - 7.000.............................

0 7.000 -'8.000.............................

0 8.000 - 9.000.............................

0 m

?

9.000 - 10.000............................

0 L

10.000 - 11.000...........................

0 L

11.000 - 12.000...........................

0 L

Greater:than 12.000.......................

0 O

TOTAL NUMBER OF INDIVIDUALS REPORTED 1770 The above information is submitted for the total number of L

individuals for whom personnel monitoring was: (check one) 10 CFR 20. 407 (a) (1)

Required under 10 CFR 20.202(a) or 10 CFR 34.33(a) during the calendar year.

-( f 10 CFR 20.407 (a) (2) g X

Provided during the calendar year.

  • Individual. values exactly equal to the values separating i

exposure ranges shall be reported in the higher range.

9003090455 900227 PDR ADOCK 05000302i R

pyy 3<

u 1

t

4 Mg CRYSTAL RIVER UNIT 3 P.O.

Box 219 Crystal River, Fl.

32629 License No. DPR-72 Crystal River Unit 3 Technical Specifications Report End of the Year Report for 1989 WORK AND PERSONNEL > 100 MREMS TOTAL MANREM JOB FUNCTION UTILITY STATION CONTRACT UTILITY STATION CONTRACT REACTOR MAINTENANCE O

O 6

0.063 0.381 2.039 OPERATION OPERATIONS 0

3

.O O.000 0.642

'O.000 AND HP AND LAB 0

0 2

0.000 0.112 0.709 SURVE!LLANCE SUPERVISORY 0

0 0

0.019 0.023 0.054 ENGINEERING 1

0 0

0.196 0.000 0.005 ROUTINE MAINTENANCE 74 88 114 27.485 27.484 40.568 PLANT OPERATIONS 1

22 0

0.102 5.782 0.035 MAINTENANCE HP AND LAB 0

33 60 0.000 14.796 25.985

$UPERVISORY 1

5 6

1.700 3.832 2.444 ENGINEERING 5

1 37 2.697 0.434 26'.224 INSERVICE MAINTfNANCE 12 5

1 4.339 1.622 7.246 INSPECT 10N OPERATIONS 0

4 0

0.000 1.083 0.000 HP AND LAB 0

1 5

0.000 0.424 2.191 SUPERVISORY 0

0 2

0.048 0.029 0.532 ENGINEERING 2

0 16 0.689 0.007 10.982 SPECIAL HAINTENANCE O

O O

0.000 0.000 0.000 PLANT OPERATIONS 0

0 0

0.000 0.000 0.000 MAINTENANCE HP AND LAB 0

0 0

0.000 0.000 0.000 SUPERVISORY 0

0 0

0.000

-O.000 0.000 ENGINEERING 0

0 0

0.000 0.000 0.000 VASTE~

HAINTENANCE O

4 1

0.042 0.849 0.126 PROCESSING OPERATIONS 0

0 0

0.000 0.027 0.000

. HP AND LAB 0

6 0

0.000 2.423 0.019 SUPERVISORY 0

1 0

0.005 0.770 0.000 ENGINEERING 0

0 1

0.000 0.000 0.218 REFUELING MAINTENANCE O

O O

O.000 0.000 0.000 OPERATIONS 0

0 0

0.000 0.000 0.000 HP AND LAB 0

0 0

0.000 0.000 0.000 SUPERVISORY 0

0 0

0.000 0.000 0.000 ENGINEERING 0

0 0

0.000 0.000 0.000 TOTALS HA!NTENANCE 86 97 122 31.5,29 30.336 49.979 OPERATIONS 1

29 0

0.102 7.534 0.035 HP AND LAB 0

40 67 0.000 17.755 28.904

$UPERVISORY 1

6 8

1.772 4.654 3.030 ENGINEERING 8

1 54 3.582 0.441 37.429 SUB TOTAL 96 173 251 37.385 60.720 119.377 GRAND TOTAL: PERSONNEL > 0.1 REM, 520; STATION DOSE; 217.482 REM

~

-u e,,-c

,m, 4 3 s

~

t k

L

p'?
!^

t i

t 17 p

CRYSTAL' RIVER UNIT 3

. STANDARD: ANNUAL REPORT ON' REACTOR VESSEL MATERIAL I

SURVEILLANCE-CAPSULES AS REQUIRED.BY.>TS 6.9.1.5.(b).-

i REPORTING PERIOD I

-JANUARY

.1, 1989 TO DECEMBER:31', 1989 x

Caosules~-Current 1v Installedi

-i

U.

. Holder

'i

W Capsules Igbjit Position Installed ZY Top-OC3-F-Bottom CR3-A XW Top CR3-E

-Bottom TMI1-B-

-t

.YX Top TMI2-D Bottom-OC3-D YZ, Top TMI2-LG1 Bottom TMI2-LG2'

WZ Top OC2-B.

Bottom CR3-LG2

(

WX Top OC3-C-t Bottom

'TM I 1 - F.

INSERTION / WITHDRAWAL

SUMMARY

l o

The -- reactor. head. was not' removed during -1989 and-- therefore no

' insertions or withdrawals have occurred.

..l

'-1 IRRADIATION LOCATION

'Same as-listed above.

-1 1

~

l

U t;,;,.

fcx " n.,

t-1 lS 4 -17 i a

O f aJo, j

h 6 is /

s OWNERSHIP'OF CAPSULES

?-.

Florida Power. Corporation:

w CR3-A-CR3-E-CR3-LG2 (B&W: Owners Group) 4 1

Duke-Power Company:

OC2-B

'OC3-C-

.OC3-D i

OC3-F Metropolitan Edison Company:

J TMI1,

L THI1-F

.TMI2-D ff -(j.

TMI2-LG1 (B&W Owners. Group)-

J TMI2-LG2 (B&W Owners Group) l.

h I

l}

I lj i

i l~ *

.,f-f '.

L' l

(

f it k

p

' $M /

m.. -

L

n

.1 p;<

g, f...

l Wil:L N

i m",,; y 1

1 4

f.

s t,

a..

'-4 CHALLENGES TO' PRESSURIZER RELIEF'AND CODE ~ SAFETY VALVF.1-

)

FOR 1989-

+

a I

lv l

i

[ue

. The.e..were no challenges to'the pressurizer relief and code' r

i safety valves'for-1989'.

l.

2 1

j

~ f

. y:

A I

5

'<1

',[

3 A

P

\\-

<,u 4

1 s

+

l

b -

3 5

e

- Is i

1 e

4 i

a m

-