Reference LCR 90-01 1
i l
ATTACHMENT 2 i
~
MARKED-UP TECHNICAL SPECIFICATION PAGES l
i i
\\
l i
i 1
.s 4
1 4
.l I
??
P,Q2090031ADOCKoOh[
=...
INSERT 1
~
APPLICA8ILITY SURVEILLANCE REQUIREMENTS 4.0.1-Surveillance Requirements shall be met during the OPERATIONAL CONDITIONS or other conditions specified for individual Limiting conditions for Operation unless otherwise stated in an individual Surveillance Requirement.
4 ance Requirement Hali be performed withiri the specif ed
~
~
time interval with:
A maximum allowable extension not to exceed 25% of the surveillance a.
interval, but m_
_ m,__;.,__, _ _ _...,,__ __... ______. n._
_._.._,22.___
_m_,s
_.___2 s on.,___
____,,,_2
..._._,is____
_m 4.0.3 Failure to perform a Surveillance Requirement within the allowed surveillance interval, defined by Specification 4.0.2, shall constitute a failure to meet the OPERABILITY requirements for a Limiting Condition for Operation.
The time limits of the ACTION requirements are applicable at the time it is identified that a Surveillance Requirement has not been performed.
The ACTION requirements may be-delayed for up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to permit the completion of the surveillance when the allowable outage time limits of the ACTION requirements are less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Surveillance requirements do not have to be performed on inoperable equipment.
l 4.0.4 Entry into an OPERATIONAL CONDITION or other specified applicable condi-tion shall not be made unless the Surveillance Requirement (s) associated with the Limiting Condition for Operation nave been performed within the applicable surveillance interval or as otherwise specified. This provision shall not prevent passage through or to OPERATIONAL CONDITIONS as required to comply with ACTION requirements.
4.0.5 Surveillance Requirements for inservice inspection and testing of ASME-Code Class 1, 2, & 3 components shall be applicable as follows:
Inservice inspection of ASME Code Class 1, 2, and 3 components and a.
inservice testing of ASME Code Class 1, 2, and 3 pumps and valves shall be performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda as required by 10 CFR 50, Section 50.55a(g), except where specific written relief has been granted by the Commission pursuant to 10 CFR 50, Section bO.55a(g)
(6) (1).
b.
Surveillance intervals specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda for the inservice inspection and testing activities required by the ASME Boiler and HOPE 0'2EK 3/4 0-2 l
l L-
l m
..+
- g-
/3/4.0 APPLICABILITY L
BASES (Con't) p Specifications 4.0.1 through 4.0.5 establish the general requirements appli-cable to Surveillance Requirements.
These requirements are based on the j,
Surveillance Requirements stated in the Code of Federal Regulations, j
" Surveillance requirements are requirements relating to test, calibration,
'or inspection to-ensure that the necessary quality of systems and components is
_Caintained, that facility operation will be within safety-limits, and that the--
limiting conditions of operation will be met."
Specification 4.0.1 establishes the requirement that surveillances must be
. performed during the OPERATIONAL CONDITIONS or other conditions for which the requirements of the Limiting Conditions fnr Operation apply unless otherwise L
state'd in an individual Surveillance Requirement.
The purpose of this 1
specification is to ensure that surveillances are performed to verify the i
operational status of systems and components and that parameters are within j
specified limits to ensure safe operation of the facility when the plant is in j
an OPERATIONAL CONDITION or other specified condition for which the individual Limiting Conditions for Operation art applicable.
Surveillance Requirements 1
do not have to be performed when the facility is in an OPERATIONAL CONDITION 3
for'which the requirements of the associated Limiting Condition for Operation
'I mm2 do not apply unless otherwise specified.
The Surveillance Requirements associated with a Special Test Exception are only applicable when the Special Test Exception is-used as an allowable exception to the requirements of a specification.
Specification 4.0.2 establishes the conditions under which the specified ti.me
-interval for Surveillance Requirements may be extended.
Item a. permits an j
allowable extension of the normal surveillance interval to facilitate surveil-lance scheduling and consideration of plant operating conditions that may not l
1 - be suitable for conducting the surveillance; e.g., transient conditions or j
' other ongoing surveillance or maintenance activities.
Item b.' limits the use
_ of.the provisions of item a. to ensure that it is not used repeatedly to.exten the-surveillance interval beyond that specified.
The limits of Specification l
--4.0.2 are based on engineering judgment and the recognition that the most pro-l n bable result of any particular surveillance being performed is the verificatio I
I of conformance with the Surveillance Requirements.
These provisions are suf-
' ficient to ensure that the' reliability ensured through surveillance activities is not significantly degraded beyond that obtained from the specified surveil-I L
l lance interval.
l Specification 4.0.3 establishes the failure to perform a Surveillance Require-j ment within the allowed surveillance interval, defined by the provisions of Specification 4.0.2, as a condition that constitutes a failure to meet the OPERABILITY requirements for a Limiting Condition for Operation.
Under the provisions of this specification, systems and components are assumed to be OPERABLE when Surveillance Requirements have been satisfactorily performed l
within the specified time interval.
However, nothing in this provision is to HOPE CREEK B 3/4 0-4
',e
}
y.1 s. :
?
94;
- i :
i
Reference:
LCR 90-01 l
U INSERT FOR TECENICAL SPECIFICATION - 4.0.2 INSERT 1 i.
4.0.2 Each Surveillance Requirement shall be performed within its.
2 specified surveillance interval with a maximum allowable extension not-to exceed 25 percent of the specified surveillance interval.-
i l
INSERT FOR TECHNICAL SPECIFICATION BASIS - 54.0.2 b
INSERT 2
]
-i i
w I
Specification ~4.0.0 establishes the limit for which the specified time l
l interval.for Surveillance Requirements may be extended.
It permits an allowable-extension of the normal surveillance interval to facilitate surveillance scheduling and consideration of plant-operating conditions:
-that may not be suitable for conducting the surveillance; e~.g.,
transient conditions or other ongoing surveillance or maintenance activities.
It also provides flexibility to accomodate the length of a:
- fuel cycle for surv3111ances that are performed at each refueling i
outage and are specified with an 18-month surveillance interval. It is F
not intended that this provision-be used repeatedly as a convenience to extend surveillance intervals beyond that specified for surveillances-that are not performed during refueling outages. 'The limitation of Specification 4.0.2 is based on engineering judgement and the i
recognition that the most probable result of any particular surveillance being performed is the verification od conformance with the Surveillance Requirements. This provision is sufficient to ensure that-the reliability ensured through surveillance activities is not significantly degraded beyond tht obtained from the specified surviellance interval.
,,