ML20011A604

From kanterella
Jump to navigation Jump to search
Forwards LER 81-051/03L-0
Date released: 01/25/2020 Download: ML20011A604


LER 81-051/03L-0:on 810925,during Normal Operation,Coupling Came Apart on 3EA Reactor Motor Operated Valve Board Motor Generator Set.Caused by Slippage of Retainer Ring.Ring Replaced
ML20011A611
Person / Time
Site: Browns Ferry 
Issue date: 10/23/1981
From: Holder G
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20011A611 (2)
Forwards LER 81-051/03L-0
ML20011A603
Person / Time
Site: Browns Ferry 
Issue date: 10/23/1981
From: Green H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20011A603 (1)