Deficiency Rept Re Use of Incorrect Welding Procedure During Welding Operations on Reactor Vessel Vent Sys,Initially Reported 810915.Evaluation Ongoing
ML20010J363
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 09/15/1981
From: Curran J
SOUTHERN CALIFORNIA EDISON CO.
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8109300371
Download: ML20010J363 (1)


Text

,.

50.55(e) Report Docket No. 50-361 Southern California Edison Company SCE P

O. BOX LOO 2 2 44 W ALN UT C. ROVE AVEN U E ROSEMF AD. CALIFORNI A 91770 J. M. CU R R AN

,, g,gg g

= ~.

...ou.u n.nu..~c.

September 15, 1981 Mr. R. H. Engelken, Director Office of Inspection and Enforcement J/f

{

U. S. Nuclear Regulatory Commission

'v Of 7h(

Region V Ich 3 9

Suite 202, Walnut Creek Plaza ggp8S gg " n@

1990 North California Boulevard J

Walnut Creek, California 94506

{

Dear Mr. Engelken:

4

/

(.o to Subj ect:

Docket No. 50-361 San Onofre Nuclear Generating Station, Unit 2 This letter confirms verbal notification on Sep-tember 15, 1981, of a condition discovered in construction which is considered reportable in accordance with 10CFR-50.55 (e).

This condition involves the use of an incorrect welding procedure during welding operations on the reactor vessel vent system.

We are performing cn evaluation of this condition and will submit a report in accordance with 10CFR50.55(e)(3).

If you have any questions or require additional information, please let me know.

Very truly yours,

, 4 bv ; < ~

cc:

Dr. L. T. Papay A. E. Chaffee (NRC, San Onofre Units 2 and 3) 6! D ohh

^

PDR gl-15a 1