ML20010H904

From kanterella
Jump to navigation Jump to search
Forwards LER 81-052/03L-0.Detailed Event Analysis Encl
Date released: 01/24/2020 Download: ML20010H904


LER 81-052/03L-0:on 810812,standby Bearing Water Makeup Pump Removed from Svc.Caused by Need to Repair Bonnet Leak in Valve in Suction Line to Pump.Pump Returned to Svc After Repair Completed
ML20010H913
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 09/11/1981
From: Mcbride M
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20010H913 (1)
Forwards LER 81-052/03L-0.Detailed Event Analysis Encl
ML20010H903
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 09/11/1981
From: Warembourg D
PUBLIC SERVICE CO. OF COLORADO
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20010H903 (4)