September 21, 1981 0FFICE OF INSPECTION AND ENFORCEMENT EN 81-32 NOTIFICATION OF SIGNIFICANT ENFORCEMENT ACTION r

,y$3 ;' J l n.,

Licensee: Public Service Electric and Gas Company, Newark, New Jersey C'5 Docket Nos. 50-272 and 50-311 4'

/j ' j'/j f gb'P > 1, y ; d) i Salem Nuclear Generating Station, Units 1 and 2

,s e

Subject:

PROPOSED IMPOSITION OF CIVIL PENALTIES - $40,000 d

 % 2';rtex r.. gn/ ul:r g

wegg This is to infom the Commission that a Notice of Violation and a' Notice of Proposed Imposition of Civil Penalties in the amount of Forty Thousar,d, Dollars.

will be issued on or about September 24,1981 to Public Service Electri,c an,d' Gas Company of flewark, New Jersey. This action is based on apparent items of non-ccmpliance at the Salem facility which demonstrated inadequacies in the manage-ment of the licensee's physical secu'rity program.

These items concecaed the abuse of the licensee's photobadge system by the site security force.

A news release has been prepared and will be issued about the time the licensee receives the Notice. The State of New Jersey will be notified.

It should be noted that the licensee has not been specifically informed of the enforcement action. The schedule of issuance and notification is:

Action Signed September 21, 1981 Mailing of Notice September 24, 1981 Telephone Notification of Licensee September 24, 1981 Telephone Notification of State September 24, 1981 NRC News Release to be made following Licensee Notification The licensee has 30 days from ti,e date of the Notice in which to respond.

Following NRC staff evaluation of the response, the civil penalties may be remitted, mitigeced or impo:;ed by Order.

Contact:

G. Barber, IE 24785 R. Wessman, IE 24900 D. Thompson, IE 24909

'Ob Distribution:

Transmitted H St.

Chairman Palladino Commissioner Ahearne ACRS Comissioner Gilinsky Commissioner Roberts C. C. Kammerer, CA Commissioner Bradford S. J. Chilk, SET,Y F. J. Remick, PE

.Of Phillips: Y,' / o IE:HQ MNBB:

W. J. Dircks, ED0 H. R. Denton, NRR C. Michelson, AE0D R. H. Vollmer, NRR Landow:

J. J. Fouchard, PA T. E. !!urley, NRt J. J. Cummings, 0IA H. S. Bassett, HPA R. Mattson, NRR

11. K. Shapar, ELD D. Eisenhut, NRR Air Rights: /Jl / 3 S. H. Hanauer, NRR G. W. Kerr, OSP Regional Directors:RI k;M RII C/ ! 2 Willste:
  • /Y Mail RIII // / 0 7 J. G. Davis, NMSS Dbcument Met. Br. (PDR)

V R. Minogue, RES S. Ebbin, NS0C PRELIMINARY INFORMATION - NOT FOR PUBLIC DILCLOSURE UNTIL SEPTEMBER 24, 1981 Q$

3 5

ih'3 g9g230810921 0

EN-81-032 PDR