ML20010G297

From kanterella
Jump to navigation Jump to search
Forwards LER 80-091/01X-0
Date released: 01/24/2020 Download: ML20010G297


Ro:Ie Bulletin 80-11 Analysis Determined That Listed Walls Would Be Overstressed During Seismic Event
ML20010G307
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/31/1981
From: Murray T
TOLEDO EDISON CO.
To: MCGREGOR L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010G307 (1)
LER 80-091/01X-0:on 801223,IE Bulletin 80-11 Analysis Determined That Listed Walls Between Control Room & Stairway AB-1 Would Be Overstressed During Seismic Event.Caused by Outdated Analytical Methodology Used by A/E
ML20010G303
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 09/02/1981
From: Mekbel C
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010G303 (13)
Forwards LER 80-091/01X-0
ML20010G296
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 09/01/1981
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010G296 (1)