YANKEE ATOMIC ELECTRIC C0!1PANY R0WE, MASSACHUSETTS EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT JAN - JUNE 1981 8109150180 810831 DR ADOCK 05000
YANKEE AR)MIC ELECTRIC COMPANY, ROWE, MllSS.
Effluent And Waste Disposal Quarterly Report Gaseous Effluents - Summation All Releases Table 1A
_ _1_98_1 Quarter Unit January February March
( 1
)
Seconds During Period Secs.
2.42E06 2.42E06 3.02E06 7.86E06 Fission 6 Activation Gases Total Release Ci 2.44E01 1.70E01 2.28E01 6.42E01 Average Release Rate For Period
.ici/sec 1.01E01 7.02E00 7.53E00 8.16E00 Percent Of Technical Specification Limit 1.82E00 1.12E00 1.29E00 1.40E00 Iodines Total Iodine - 131 Ci (1.36E-06 6.03E-05
<2.10E-06 6.03E-05 Ave. Release Rate For Period
.tCi/sec <5.62E-07 2.49E-05
<6.95E-07 7.67E-01 Percent Of Technical Specification 44.32E-02 1.82E00 (1.79E-02 5.83E-01 Limit Particulates Total Gross ( 8, y )
Ci 1.87E-06 4.55E-06 1.89E-07 6.61F-06 Particulates With ilalf-Life > 8 Days Ci 1.87E-06 4.55E-06 1.89E-07 6.61E-06 Ave. Release Rate For Period
- uCi/sec F-07 RF-0
-OR R E F-o
Percent Of Technical Specification Limit 3.61E-02 4.82E-02 1.70E-02 3.18E-02 Gross Alpha Radioactivity lCi 41.03F-08 (4. 35E-08 6.53E-08 6.53F-08 Tritium Total Release Ci 9.96E-02 1.09E-01 1.76E-01 3.85E-01 Ave. Release Rate For Period uCi/sec 4.11E-02 4.50E-02 5.83E-02 4.90E-02 Percent Of Technical Specification 4
2.26E-03 2.35E-03 3.25E-03 2.66E-02 Limit i
Applies to particulates with icif-lives > 8 De, s Maximum Gross. Radioactivity Release Rate:
January 2,1981 (0910) - 5.14E01 uCi/sec.
February 26,1981 (0845) - 1.03E02 uCi/sec.
March 19, 1981 (1100) - 8.21E02 uCi/sec.
YANklili AT0hllC Ill.l:CTit1C C0hil'ANY, IU M., blASS. -
u EF' FLUENT AND WASTE DISPOSAL TABLE IB GASEOUS EFFLUENTS 1981 Nuclides lleleased Unit January February blarch Quarte r (1; i
l Fission Gases l
Ci 7.95E-03 6.12E-03 1.49E-02 2.90E-02 Krpton-85 Krpton-85bl Ci 3.07E-01 1.70E-01 2.18E-01 6.95E-01 Krpton-87 Ci 3.28E-01 1.91E-01 2.21E-01 7.40E-01 Krpton-88 Ci 3.15E-01 3.11E-01 3.71E-01 1.20E00 Xevon-133 Ci
_1.00E01 7.68E00 1.03E01 2.80E01 Aenan-135 Ci 4.90E00 3.03F00 4.1RF00 1 71F01 Aenon-135N L1 7.69E00 5.03E00 6.90E00 1.96E01 Xenon-138 Ct 2.69E-01
- 1. 49Ti-01 1.72E-01 5.90E-01 Others(Specifv)
Ci Xenon-133M Ci 2,41E-02 1.82E-01 1.36E-01 3.42E-01 Argon-37 Ci 6 06F-02 3.36E-02 J.10E-02 1.45E-01 Argon-41 Ci 3.28E-01
__1.59E-01 1.72E-01 6.59E-01 Carboa-14_
Ci 3.46E-03 2.66E-03 6.49E-03 1.26E-02 Ci 1.17E-02 2.87E-02 2.75E-02 6.79E-02 Xenon-1319 Unidentified Ci Total for Period Ci 2.44E01 1.70Fri 2.28E01 6.42E01 l
Iodines l
Iodine-131 Ci
<1.36F-06
__6.03F-05
<?
10F-05 6.03E-05 1odine-133 Ci
< 1.31E-06
<1.57E-06
< 1. 96E-06
<4.87E-06 lodine-135 CI
< 2.29E-06
< 2.59E-06
< 3.15E-06
< 8.03E-06 Total for Period Ci (4.99E-06 6._03E-05
<7.21E-06 6.03E-05 l
Tritium l Ci l 9.96E-02 l 1.09E-01 l1.76E-01 l 3.85E-01 l
l Particulates l
l I
btrontium-89 Ci
<5.96E-08 4.29E-07
< 7.34E-08 4.29E-07 Strontium-90 Ci
< 6.12E-09 4.76E-07
< 7.53E-09 4.76E-07
. Cesium-134 Ci
< 1.10E-07 3.91E-07
< 9.10E-08 3.92E-07 C'n s i n m - 1 3 7 ri 1.41E-07 7.10E-07
< 8.97E-08
- 8. 51 E-07 Barium-Lanthanium-140 Ci
< 3.54E-07
< 2.86E-07
< 2.96E-07 49.36E-07 Antimony - 125 Ci
< 7.65E-07 4 6.12E-07 (6.33E-07 42.01E-06 Coha1t-58
__C i
< 1.00E-07
< 7.86E-08
< 8.52E-08
< 2.64E-07 Coba1t-60 Ci 1.55E-06 1.79E-06 1.89E-07 3.53E-06 Iron-59 Ci
< 2.20E-07
< 1. 76E-07
<1 ROF-07
- s.76E-07 Chromium-51 Ci
<. 7. 58E-07
< 6.06E-07
<6.32E-07
<2.00E-06 Zirconlum-Niobium 99 Ci
< 1.79E-07 2.63E-07
< 1. 47E-07 2.63E-07 Ci
< 1.32E-07
< 1.06E-07 41.09E-07
< 3.47E-07 Cerium-141 Cerium-144 Ci
( 6.1RE-07 4 4.95E-07
< 5.05E- 07
< 1.62E-06 Antimony-124 Ci
< 1.55E-07
< 1.31E-07 4.1.15E-07
< 4.01E-07 Ci blanganese-54 1.83E-07 4.90E-07 48.90E-08 6.73E-07 Silver-11nu Ci
< 1.65E-07
< 1.28E-07 4 1.32E-07
< 4.25E-07 o
Tota 1 for Pcriod Ci 1.87E-06 4.55E-06 1.89E-07 6.61E-06
/
YANKEE ATOMIC ELECTRIC COMPANY, ROWE, MASS.
EiFLUENT AND WASTE DISPOSAL QUART 5RLY REPORT LIQUID EFFLUENTS - SUM.MATION OF ALL RELEASES TABLE 2A 1981 Unit January Febniary March Qubter
~
Fission and activation products Total release (not including tritium, gases., alpha)
C1 1.425-0.' 5.34E-03 1.49E-03 8.25E'-03 Average diluted. concentration during period pCi/ml -7.10E-11 2.55E-10 5.64E-11 1.23E-10 Percent of Applicable Limit 4.s0F-0 a xdF-0?
7 RAF-Oz 1 RRF-n?
~ I.
Total-Release Ci 5.48E00 1.25E01 4.76E00 2.27E01 Average dilutel concentration duringeperi-2 uCi/ml
- 2. 74 E'-0 5.98E-07 1.80E-07 3.37E-07 Percent of applicable limit 6.00F-03 1.1?F-07 9.13F-0 1.99F-02 Dissolved and entrained gases i
Total Release Ci.
6.59E-02 7.21E-01 1.98E-0:
8.07E-01 gp io UCi/ml 3.29E-09 3.45E-08 7.50E-10 1.20E-08 Percent of applicable limit 1.10E-01 1.15E00 2.50E-02 4.00E-01 Gross Alpha radioactivity Total Release Ci.
9.16E-08 4J77E-08 9.94E-0E 1.49E-07 i Alpha'Aveiage Concentration uCi/ml 4.ggp.1g 7.7pp.1s z_76p_1r 2.21E-15 Volume of waste released (prior to dilution)
Liters 1.52E06 1.85E06 1.88E06 5.25E06 Volwne of dilution water (used during period) liters 2.00E10 2.09E10 2.64E10 6.73E10 Maximum Concentration ( B,y ) Released To Unrestricted Area January - January 31,'1981 (1820) - 5.11-09 uCi/ml February '- Februaiy 13,1981 (0945) - 1.08E-08 uCi/ml March - March 19,1981 (1730) - 2.26E-09 uCi/ml J
YANKEE ATGIIC ELELTRIC CGIPANY-RONE, R1SS.
EFFLUENT AND WASTE DISPOSAL QUA:fERLY REPORT LIQUID EFFLUENTS TABLE 2A 1981 Nuclides Re] eased Unit January Febmary March Quarter (1)
Strontium-89 Ci 5.16E-05 1.02E-04 4.83E-05 2.02E-04 Sttontium-90 Ci 1.59E-06 3.12E-06 1.47E-06 6.18E-06 cmin -T u ri 6.85E-05 1.84E-04 1.50E-04 4.02E-04 Cesium-137 Ci
- 1. 56E-.04 3.74E-04 2.47E-04 7.77E-04 Todine-131 Ci 2.20E-04 2.47E-03 1.77E-04 2.87E-03 Cobalt-58 Ci (2.38E-06 4.80E-05 1.74E-05 6.54E-05 Cobalt-60 Ci 1.65E-05 6.57E-05 1.98E-05 9.97E-05 Iron-59 Ci c5.02E-06 1.88E-05 8.73E-06 2.76E-05 Zinc-65 Ci
<6.09E-06 (9.42E-06 (5.35E-06
<2.09E-05 Mancanese-54 Ci 3.74E-06 3.39E-C5 1.78E-05 5.54E-05 Chromium-51 Ci
<2.61F-05 5.55E-05 1.24E-05 6.79E-05 Zirconium-Niobium-95 Ci
<4.22E-06 2.42E-06 (4.17E-06 2.42E-06 Molybdenum-99 Ci 41.64E-05 4.58E-06
<1.58E-05 4.58E-06 Technetium-99M Ci z_7sp_n7 7_T1F-n6 41.46F-06 7.64F-06 Barium-Lanthanum-140 Ci
,_qqp_06 s.42F-05 2.67E-05 8.25E-05 Cerium-141 Ci
<3.65E-06 (8.02E-06 8.07E-07 8.07E-07 nn e nin,-lot Ci
< 2 Rap-n6 7 TRF-06
~i_91F-07 7.74F-06 Iodine-133 Ci 8.57E-05 2.50E-04 8.46E-07 3.37E-04 Selenium-75 Ci 2.85E-06
<8.49E-06 (3.58E-06 2.85E-06 Silver-110M Ci
( 3.85E-06 46.21E-06
<3.31E-06
< 1. 34E-05 Antimony-124 Ci (3.34E-06
<4.91E-06
< 2.49E-06 (1.07E-05 Carbon-14 Ci 8.12E-04 1.61E-03 7.59E-04 3.18E-03 Ci
<1.65E-05
<3.56E-05
< 1.47E-05
<6.68E-05 Cerium-144 Unidentified Ci
<3.97E-06 4.92E-05 2.39E-06 5.16E-05 Total for Period (above) Ci 1.42E-03 5.34E-03 1.49E-03 8.25E-03 Xenon-133 Ci 6.56E-02 7.18E-01 1.98E-02 8.03E-01 Xenon-135 Ci 3.49E-04 3.20E-03 1.79E-05 3.56E-03 Tritium Ci 5.48E00 1.25E01 4.76E00 2.27E01
t YANKEE ATOMIC ELECTRIC COMPANY-RONE, M\\SS.
SOLID WASTE SilIPMEVf REPORT 1981 Evaporator Bottoms
@arter (1)
January Febluary March ft.3 2.10E02 2.10E02 Ci 1.00E00 1.00E00 Dry Compressible Waste January February March Quarter (1) ft.
3.45E02 5.75E02 9.20E02 Ci 1.72E-02 3.41E-01 3.58E-01 Decontamination Soln.
Quarter ( )
ft.
Ci Other:
Quarter ( )
ft.3 Ci i
Solid Waste Disposition No. of Shipments Dates Trans. Mode Desunation c
1 February 25, 1981 Truck Barnwell, S. C.
1 March 27, 1981
YANKEE ATOMIC ELECTRIC COMPANY, RONE, MASS.
Effluent And Kaste Disposal Quarterly Report Gaseous Effluents - Sumation All Releases Table 1A 1981 iQuarter Unit April May June l(
2
)
Seconds During Period l Secs. 2.42E06 l 2.42E06 3.02E06 7.86E06 Fission 6 Activation Gases Total Release Ci 3.27E-02I4.22E01 1.25E01 2.97E01
! 1 nRF-02 l s.3 7Foo Average Release Rate For Period hci/sec 5.16E00 1.23F01 Percent Of Technical Specification Limit 7.32E-01 3.38E-01 1.79E-02 2.72E-01 Iodines l
Total Iodine - 131 l Ci kl.81E-06 ! 7.81E-05! 6.84E-Oh 8.49E-0 Ave. Release Rate For Period uCi/secb. ARF-n? I 7
T 2 3 F-0.5
' 76F-n6 1 nRn-n Percent Of Technical Specification l 1.32E00l,9.28E-02 4 5.16E-02 {
5.07E-01,
, Limit Particulates Total Gross ( S,y )
Ci l 5.20E-07 l 1.25E-05 2.24E-06 1.53E-05!
lParticulatesWithHalf-Life >8 Days lCi l5.20E-07 1.25E-05l2.24E-06l1.53E-05!
> Ave. Release Rate For Period
- uCi/sek 2.15E-07 5.17E-06l7.40E-07l1.94E-06i
, Percent Of Technical Specification j
5.07E-02l.2.60E-02l;3.33E_02 Limit 1.99E-02 Gross Al,M Radioactivity
- Ci l4.48E-09' a.01E-08't2.12E-08' 4.46E-Od l
I Tritium Total Release i Ci l 3.08E-01 l 3.76E 2.79E-01l 9.63E-01 Ave. Release Rate For Period
'uCi/sec 1.27E-01 I 1.55E-01! 9.24E-02! 1.22E-01I Percent Of Technical Specification i
I i
Limit I s; l6.28E-03 4.56E-03l 2.71E-03l, 4.11E-02, Applies to particulates 4ith half-lives > 8 Days Maximum Gross Radioactivity Release Rate:
i l
April 14, 1981 (0805) - 1.83E02 uCi/sec.
May 3, 1981 (2330) - 5.97E03 uCi/sec.
June
- 41.70E01 uCi/sec.
l
~,,
r
YANKEE ATOMIC ELECTRIC COMPANY, RONE, MASS. - TABLE 1B EFFLUENT AND WASTE DISPOSAL GASEOUS EFFLUENTS 1981 Nuc1 ides Re1 eased llinit l April May June Ouarte(2) l Fission Gases l
Arpton-85 Ci
! 1.01E-02 2.60E-01 2.37E-04 2.70E-01 Krpton-S5M Ci _ l 1.22E-01 3.11E-02 e 1.03E-03 1.53E-01
- 3. 00ii-Uz
< 1. a / L-0 3
- 1. sun-01 Krpton-87 Ci l1.zuii-01 hrpton-88 Ci l 2.07E-01 5.2411-02 4 2.48E-03 2.59E-01 Xenon-133 Ci 5.98E00 2.55E01 1.74E-02 3.15E+01 Aenon-135 Ci 2.38E00 1.48E00
< 8.05E-02 3.86E00 Aenon-J aabl Li a.aeLUU 8.97E-01
< 9.95E-03 4.77E00
'\\ e n o n - 13 8 C1 9.55F-02 2.56F-07 4
'.41F-01 1 71F-01 Ot hers (Spec i fvl Ci Xenon-133M Ci 5."2E-02 3.90E-01
< 4.00F-0; 1 don-01 Argon-37 C1 2.24E-02 3 J'IE-01 1.58E-04 3.50E-01 Arcon-41 Ci 8.4bh-02 E 4E-02
( 1.09E-04 1.08E-01 Carbon-14 Ci 4.39E-03 8.28E-02 1.14E-04 8.73-02 Ci 3.49E-02 5.41E-01 1.48E-02 5.91E-01 y,,,,,, _ 3 3 y lin i den t i fi ed Ci Tota 1 for Period Ci 1.25E01 2.97E01 3.27E-02 l 4.22E01 l
Iodines l
Todine-131 Ci 41.81E-06 7.81E-05 6.R4F-06 8.49E-05 Iadine-133 Ci c1.70E-06 1.89E-06 C 4.03E-06 1.89E-06 lodine-135 Ci lz 2. 72E-06 (2.46F-06 45.24F-06 (1.04F-05 Total for Period Ci K6.23E-06 8.00E-05 l 6.84E-06 8.68E-05 l2.70F-01 l 9.63E-01
}
l_
Tritium l Li l t nen n1 lt An n1 l
l Particulates l
l dtrontium-89 l Li l 3,47p_g7
, 37p_g, z gnn_n, o:n-07 Strontiun-90 l ri 4 1.24E-08
<-2. 09E- 08 42.61E-08 45.94E-08 Cesium-13i l Ci
<1.06F-07 44.2dF-07
.2 ROF-07 9 inn-n?
ccgie-137 c;
41.05E-07 4 4.18E-07 u3.17E-07 8.40E-07 Barium-Lanthanium-140 Ci 43.41E-07 41.37E-Ob
.:9.7.,E-07 c 2.68E-06 Ci 4 7.00E-07 42.91E-06 d 2.13E-06
' 5. 75E-06 Antimonv-125 Coba1t-58 Ci
< 9.41E-08 3.27E-06 6.46E-07 3.92E-06 Cobalt-60 Ci 3.73E-07 1.47E-06 5.96E-07 2.44E-06 l
Iron-59 Ci c.2.07E-07
<8.39E-07 s6.14E-07
<l.66E-06 l
Chromium-51 Ci
< 7.15E-07 5.80E-06 c 2.12E-06 5.80E-06 2irconium-Niobium 95 Ci 41 inn-n7 c6_R w-n7 44.95E-07
.fl.35E-06 Ceriun-141 Ci 41.22E-07 44.81E-07 M 3.63E-07
'9.66E-07 Ceritn-144 Ci
' 5 71 F-07
<2.25E-06
< l.6E06 44.4SE-06 Antimony 124 Ci 41.40E-07
<5.02E-07 44.31F-07
< l.07F-06 1
Ci 4 1.03E-07 1.71E-06 6.8SE 0; Ei 06 Manganese-54 S i l var-l i nu Ci 41.49E-07 45.72E-07 44.63E-07 41.1 W.- 06 Total for Period Ci 5.20E-07 1.25E-05 2.24E-06 1.53F-05
YANKEE ATOMIC ELECTRIC COMPANY, R0h'E, MASS.
EFFLUENT AND WASTE DISPOSAL QUARTERLY REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES TABLE 2A 1981 4nd Unit Anril l Shv
. Tune Quarter Fission and activation prcKlucts Total release (not including tritium, gases _, alpha)
Ci 4.70E '4 1.61E-03 4.93E-04 2.57E-03 v
Average diluted. concentration during period pCi/m]
2.23E-11 3.04E-10 8.94E-10 9.57E-11 Percent of Applicable Limit 6.12E-04 1.82E-02 8.63E-03 4.17E-03 i
Tritiam Total Release Ci 5.31E00 1.16E01 1.94E00 1.88E01 Average diluted concentration 2.52E-07 2.19E-06 3.51E-06 6.99E-07 duringeperiod pCi/ml Percent of applicable limit 8.40E-03 7.30E-02,1.17E-01 2.33E-02 i
Dissolved and entrained gases Total Release Ci 1.03E-02 6.58E-02 2.05E-04 7.63E-02 Average diluted concentration during period UCi/ml 4.88E-10 1.24E-08 3.71E-10 2.84E-09
~
Percent of applicable limit 1.63E-02 4.13E-01 1.24E-02 9.47E-02 i
3 lGrossAlpharadioactivity Total Release Ci
< 3. 61E- 08c4.36E-08 e5.05E-08 e1.30E-07 Alpha Average Concentration uCi/ml 41.71E-15 c8.27E-15 c9.15E-14 c4.83E-15 Volume of waste released (prior to dilution)
Literf 1.32E06 5.54E05
'2.45E05 2.12E06 Volume of dilution water (used during period) liters 2.11E19 5'.29E09 5.52E08 2.69E10 Maximum Concentration ( 6,y ) Released To Unrestricted Area April - April 23,'1981 (1845) - 6'.14E-10 uCi/ml Shy - hhy 16,1981 (0135) - 2.96E-09 uCi/ml June - June 3,1981 (2040 ) - 1.51E-08 uCi/ml
L uKEE ATOfIIC ELECFRIC C01PANY-RONE, NASS.
EFF11] INT /WD WASTE D1SPOSAL QJARTERIX REPORT LIQUID EFFLUENTS-TABLE 2B 1981 Nuc1 ides Relcased Unit April May June Quarter (2)
Strontium-89 Ci 2.72E-05 4.58E-05 1.53E-05 8.83E-05 Strontium-90 Ci 1.36E-06 2.30E-06 1.36E-06 5.02E-06 resit.
13i r;
6.48E-05 2.41E-04 3.01E-05 3.36E-04 Cesium-137 Ci 1.10E-04 5.57E-04 5.31E-05 7.20E-04 Todine-131 Ci 9.30E-06 2.51E-04 6.69E-06 2.67E-04 Cobst-58 Ci 1.44E-05 3.37E-05 2.86E-05
'7.67E-05 Coba lt-60 Ci 2.71E-05 3.57E-05 5.31E-05 1.16E-04 Iron-59 Ci 3.33E-06 1.57E-06 4.60E-06 9.50E-06 7,i nc-6 5 Ci 4.78E-06
<1.00E-05 44.13E-06 41.R9E-05 u,nnnnese-s4 ci 1.16E-05 7.99E-05 3.29E-05 1.24E-04 Chromium-51 Ci 1.05E-05 E5.11E-05 2.13E-Os 3.4sE-Os Tellurium-132 Ci s1.22E-06 l8.15E-06
'<1.27E-06 l8.15E-06 Zirconium-Niobium-95 Ci 6.80E-07 (8.24E-06 2.39E-06 3.06P-n6 Molybdenum-99 Ci
- 1.3SE-05 (3.26E-05
<l.19E-05
( 5.83E-05 Technetium-99M Ci cl.53E-06
<3.87E-06
<1.17E-06
( 6. 57E-06 Barium-Lanthanum-140 Ci W9.07E-06 1.82E-05 1.43E-06 1.96E-05 Cerium-141 Ci 42.53E-06 (6.40E-06 1.07E-06 1.07E-06 Ruthenium-103 Ci
<2.45E-06 (6.15E-06 4.44E-07 4.44E-07 Rut hon i2 r,-106 Ci l<4. 66E-06
<1.06E-05 (4.01E-06
<1.93E-05 Iod ine-133 Ci
<2.45E-06 1.62E-05
<1.91E-06 1.62E-n5 Seleninm-75 Ci (2.82E-06
<7.27E-06
< 2.16E-06
( 1.22E-05 Silver-110M Ci
,<3.09E-06 (6.54E-06 f2.73E-06
< 1.24E-05 Antinony-124 Ci (2.59E-06 (6.18E-06 (1.69E-06
< 1.05E-05 Carbon-14 Ci 1.90E-04 3.20E-04 2.32E-04 7.42E-04 Cerita-144 Ci (1.17E-05 (2.94E-05 6.08E-06 6.0SE-06 Unidentified Ci
< 6. 55E-06
<1.55E-06
< 3. 7sE-07
< 8.48E-06 l Total for Period (above
) Ci 4.70E-04 1.61E-03 4.93E-04 2.57E-03 Xenon-133 Ci 1.03E-02 6.58E-02 2.05E-04 7.63E-02 Xenon-135 Ci
< 5.01E-05 (7.69E-05 (5.91E-05 ll.86E-04 Tritium Ci 5.31E00 1.16E01 1.94E00 1.88E01
YANKEE ATO.'!IC ELECTRIC CG! PANT-RONE, M\\SS.
SOLID WASTE SlillMENT REPORT 1981 Evaporator Bottoms April May June Quarter (2) ft.3 1.35E02 2.25E01 3.75E01 1.95E02 Ci 2.76E-01 2.70E-0 5.95E-01,1.14E00 Dry Compressible Waste April May Junc Quarter ( )
N-1.15E02 4.60E02 1.61E03 2.18E03 Ci 2.32E-0 6.71E-01 1.94E00 2.63E00 Decentamination Soln.
April May Junc Quarter ( )
ft.
1.50E01 1.50E01 3.00E01 Ci 1.39E00 1.60E-01; 1.55E00 f
Other: Scrap Metal, Cuno Filters, Quarter ( )
o r c_ _
Anril May June ft.3 1.05E02 9.75E01 8.25E01 2.85E02 l
Ci 7.67E-02 1.10E01 2.09E00 1.32E01 Solid Waste Disposition
.No. of Shipments Dates Trans. Mode Destination 1,
April 24, 1981 Truck Barnwell, S. C.
2 May 15 and 22, 1981 Truck 3
June 1, 1981 Truck Richland, Wa.
June 20 and 24, 1981 Truck Barnwell, S. C.
_ _ _ _ _ _ - _ _ - _ _ _ - -