ML20010F925

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 810701-0810
ML20010F925
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 08/17/1981
From: Brunner E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20010F924 List:
References
50-271-81-13, NUDOCS 8109150117
Download: ML20010F925 (1)


Text

,

l t

t

(

APPENDIX A NOTICE OF VIOLATION i

Vermont Yankee Nuclear Power Corporation Docket No. 50-271' j

Vermont Yankee Nuclear Power Station License No. DPR-28 Vernon, Vermont i

As a result of the inspection conducted on July 1 - August 10,1981, and in accord-ance with the Interim Enforcement Policy, 45 FR 56754 (October 7,1980), the following i

l violation was identified:

l A.

Technical Specification 6.5.B requires that procedures be established and implemented to provide control of activities involving radioactive material.

Procedure AP 0505, Establishing and Posting Controlled Areas. Revision 6, was developed pursuant to Technical Specification 6.5.B.

Procedure AP 0503 4

1 defines a Contaminated Area to existfen it contains loose surface contami-

)

nation in excess of 1,000 dpm/100 cr-and requires that such areas be barri-caded to show its boundary and posted with a sign reading - CAUTION CONTAMINATED j

AREA.

Contrary to the above, on July 23,1981, at 3:50 PM, an area at the exit of the RCIC room in th Torus Bay contained loose surface contamination in excess of 1,000 dpm/100 cm and entrance thereto from the West was not barricaded l

and posted as a contamination area.

This is a Severity Level V Violation (Supplement IV.E).

1 i

Pursuant to the provisions of 10 CFR 2.201 Vermont Yankee Nuclear Power Corpora-tion of Vernon, Vermont, is hereby required to submit to this office within thirty j

days of the date of this Notice, a written statement or explanation in reply,'in-cluding:

(1) the corr % tive steps which have been taken and the results achieved; (2) corrective steps that will be taS:en to avoid further violations; and (3) the date when full compliance will be achieved. Under the authority of Section 182 i

of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation. Where good cause is shown, consideration will be given to extending your response time.

4 The responses directed by this Notice are not subject to the clearance procedures 4

of the Office of Management and Budget as required by the Paperwork Reducticn Act l

of 1980. PL 96-511.

{

4[

AUG 171981 p

Oated Eldon J. Brunnet. Kh'ef Projects l

Branch fl. Divisidn of Resident i

and Project Inspection l

Y l

8109150117 810817 i

PDR ADOCK 05000271 O

PDR

- _.___._.,___..,,_._..__._____._,,___.__,_..___..,___....___.,C"*,_.,,