nist.

Docket File' RBosnak AUG 2 51981 LBF1 Rdq nTerao BJYoungblood WJohnston Anromerick nELn GEdison RMattson Docket Mos.: STM 50 AR71 M9ushbrook RHartfield,fiPA STNr,n_4pt,agq P.Tedesco 0IE (3) k!SCIC

/*

Hr. John K. Bryan lenn L. Koeste Vice President Vice President - Muclear L/PDR KansasGasandElectricCompanpCRS(16) tinfon Electric Company 201 North Market Street In01 Gratiot Street Post Office Box 14n Post Office Box 208 St. Louis, Missouri 63166 Wichita, Kansas 67201 near Gentlemen:

Subject:

S?!'fppS FSAR-Request for Additional Infomation:

Mechanical Encineering As a result of our review of your application fcr operatinq licenses we find that we need additional information regarding the SHtfPPS FSAR.

The specific infomation required is a result of the Mechanical Engineer-ing Branch review and is listed in the Enclosure.

To maintain our licensinq review schedule for the SNUPPS FSAR, we will need a resnonse to the enclosed request by September 3,1981. If you cannot meet this date, please infom us within seven days after receipt of this letter of the date you plan to submit your responses so that we may review our schedule for any necessary changes.

Please note that this nuestion was discussed by telephone with the SNUPPS staff in early a nust and a draft copy provided on August 21, 1981.

u Dlease contact Dr. G. E. Edison, SfMIPPS Licensing Pro.iect Manager, if you desire any discussion or clarificat'on of the enclosed request.

Sincerely, l

Ortstral rigne'd by:

l B..T.Y..

whinnd p g, j,

p l

. B. J. Youngblood, Chief

~ V#

Licensing Branch No.1 8

l Division of Licensing

[

9 t

i Enclosure-

^

ti <

1 r quest for Additional op

~

1 l

e 4

g Infomation 9

O cc: See next page 8109110014 810825 PDR ADOCK 05000482 A

PDR l

fl 1 r

OL: LRai CLI

.......a /..L.

omce>

odngbl'o,o,d eunms >

.qEdi o,n,,,,,,

...?.

.'.R.1........

8J,Y,hM.....

.9 nm>

Nac ronu ais tio-aci Nacu 02u OFFICIAL RECORD COPY owomi_m.

~

__ __, _ _. _ _,.. = _

fir J. II. Bryan fir. Glenn L. Kocster s

Vice President - fluclear Vice President - fluclear Union Electric Company Kansas Gas and Electric Company P. O. Box 149 201 florth flarket Street St. Louis,11issouri 63166 P. O. Box 208 Wichita, Kansas 67201 cc:

Gerald Charnoff, Esq.

Shaw, Pittman, Potts, Dr. Vern Starks Trowbridge & fladden Route 1, Box 863 1800 fl Street, fl. W.

E:ichikan, Alaska 99901 Washington, D. C.

20036 fir. William llansen Kansas City Power & Light Company U. S. fluclear Regulatory Commission ATTil:

f4r. D. T. ficPhee Resident Inspectors Office Vice President - Production RR #1 1330 Baltimore Avenue Steedman,f4issouri 65077 Kansas City, f4issouri 64141 lis. Treva Hearn, Assistant General Counsel fir. flicholas A. Petrick f4issouri Public Service Commission Executive Director, SilVPPS P. O. Box 360 5 Choke Cherry Road Jefferson City,flissouri 65102 Rockville, flaryland 20850 Jay Silberg, Esquire fir. J. E. Birk Shaw, Pittman, Potts & Trowbridge Assistant to the General Counsel 1800 14 Street, fl. W.

Union Electric Company Washington, D. C.

20036 St. Louis, f4issouri 63166 fir. D. F. Schnell Kansans for Sensible Energy fianager - fiuclear Engineering P. O. Box 3192 Union Electric Company Wichita, Kansas 67201 P. O. Box 149 St. Louis,filssouri 63166 lis. fiary Ellen Salava Route 1, Box 56 f4r. Tom Vandel Burlington, Kansas 66839 Resident Inspector / Wolf Creek flPS c/o USilRC Eric A. Eisen, Esq.

P. O. Box 1407 Birch,llorton, Bittner & f4onroe Emporia, Kansas 66801 1140 Connecticut Avenue, fl. W.

Washington, D. C.

20036 f4r. flichael C. Keener Wolf Creek Project Director State Corporation Commission lis. Wanda Christy State of Kansas 515 fl. 1st Street Fourth Floor, State Office Building Burlington, Kansas 66839 Topeka, Kansas 66612 4

v

ENCLOSURE Request For Additional Information Callaway/ Wolf Creek tECHANICAL ENGINEERING BRANCH 210.0 j

210.2 The applicant states that all circumferential breaks in the RCS piping are assumed to result in a limited separation such that the maximum flow area is less than a full break area. The applicant must provide the design information assumed for each location where limited break areas are postulated including gap size, restraint stiffness, blowdown force, and maximum restraint deflection. The results of the time-history analysis (if used) should include the break area vs. time and mass flux rate vs. time which were used to calculate the subcompartment pressurization.

In addition, all restraint locations on the RCS piping must be shown.

4