Amend 7 to License NPF-8,redefining Group of Containment Cooling Fans to Be One Fan Instead of Two Fans
ML20010F398
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 08/27/1981
From: Varga S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20010F399 List:
References
NUDOCS 8109100137
Download: ML20010F398 (4)


Text

sk#UC Og(o UNITED STATES

+

g j yg ': y g

NUCLEAR REGULATORY COMMISSION

r. 3 WASHINGTON, D. C. 20555 Y.w...+/

ALABAMA POWER COMPANY DOCKET NO. 50-364 JOSEPH M. FARLEY NUCLEAR PLANT, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 7 License No. NPF-8 1.

The Nuclear Regulatory Comission (the Commission) has found that:

A.

The application for amendment by Alabama Power Company (the licensee) dated August 24, 1981, supplemented August 25, 1981 and August 27, 1981, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions 'of ttc Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Conmission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

l i

8109100137 810827 PDR ADOCK 05000364 P

pop

~

. 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-8 is hereby amended to read as follows:

(2) Technical Scecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 7, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION ll j

L Steven. Varga; Chief

/ Operating React s Branch #1 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: August 27, 1981 I

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 7 TO FACILITY ~0PERAhlNG LICENSE NO. NPF-8 DOCKET NO. 50-364 t

Revise Appendix A as follows:

. Remove Page Insert Page 3/4'6-13 3/4 6-13 4

1 1

1 t

i F

4 b

l l

l

~, * - - - - - - ' - ~ ~ ' -

~ ~ - ' ~ ~ ~ ~

CONTAINMENT SYSTEMS CONTAINMENT COOLING SYSTEM 4

LIMITING CONDITIONS FOR OPERATION l

3.6.2.3 Two independent groups of containment cooling fans shall be OPERABLE with one fan in each group.

APPLICABILITY:

MODES 1, 2, and 3.

5 i

ACTION:

a.

With one group of the above required containment cooling fans inoperable and both containment spray systems OPERABLE, restore the inoperable group of cooling fans to OPERABLE status within 7 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

s b.

With two groups of the above required containment cooling fans inoperable, and both containment spray systems OPERABLE, restore at least one group of cooling fans to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the.following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

Restore both above required groups of cooling fans to OPERABLE status within 7 days of initial loss or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

c.

With one group of the above required containment cooling fans inoperable and one containment spray system inoperable, restore the inoperable spray system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within ti.e following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

Restore the inoperable group of containment cooling f ans to OPERABLE status within 7 days of initial loss or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.2.3 Each group of containment cooling fans shall be demonstrated OPERABLE:

a.

At least once per 31 days on a STAGGERED TEST BASIS by:

1.

Starting each fan group (unless already operating) from the control room, and verifying that each fan group operates for at least 15 minutes.

2.

Verifying a cooling water flow rate of greater than or equal to 1600 gpm to each cooler group.

b.

At least once per 18 months by verifying that each fan group starts automatically on a safety injection test signal.

FARLEY-UNIT 2 3/4 6-13 Amendment No. 7