Potential Deficiency Rept Re Nonconforming Rockbestos Cable. Sample Specimens Being Collected for Retesting.Results of Investigation & Retesting Program Will Be Submitted by 811120
ML20010F073
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 08/28/1981
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, KMLNRC-81-108, NUDOCS 8109090337
Download: ML20010F073 (1)


Text

- _

hD N ZeH&s&e, KANSAS GAS AND ELECTRIC C:>MPANY

? >f f LE CT HC COMPANY OLENN L MOESTER vre s pos we ne t sevc t s am August 28, 1981 Mr. G.L. Madsen, Chief *-

Reactor Projects Branch / Og 'f' U.S. Naclear Regulatory Commission Region IV ([ [f(

LQ j[

b 611 Ryan Plaza Drive, Suite 1000 2 -3' Arlington, Texas 76011 ';2 y....

x <' 0 81981 m ;

p.s. Mu1At recutArotu KMLNRC 81-108

- COAudl53 m G E6: Docket No. STN 50-482 g Ref: Interim Report dated June 22, 1981 transmitted 'g.y, / g by GLKoester (KMLNRC 81-090) to GLMadsen, NRC Sub: Potential 50.55(e) Report on Nonconforming Rockbestos Cable

Dear Mr. Madsen:

This letter is to provide an update on the investigation of the nonconforming Rockbestos cable which was delivered to the Wolf Creek Generating Station site as described in the Referenced Report.

The 130,000 feet of cable has been installed in nonsafety related locations or is on hold in the reel yard. None of the cable has been installed in safety related service. All of the affected cable is identified on Deficiency Reports and will be controlled by these documents pending final engineering disposition. Currer:tly, representative sample specimens are being collected for retesting.

When the retest results become available, our Architect /Eagineer will issue the final engineering disposition. The results of this investigation and retesting program will be reported to your of fice on or before November 20, 1981.

If you have any questions regarding this matter, please contact us.

Yours very truly, GLK:bb do ' 50 cc TVandel Resident NRC Inspector

':M 8109090337 810828 SI 9 PDR ADOCK 05000482 l S PDR I 201 N. Market - Wictuta, Kansas - Mad Address: PO. Box 208 I Wictuta, Kansas 67201 - Telephone: Area Code (316) 261-6451