ML20010E299

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 9036,Revision 0,for Model C-1
ML20010E299
Person / Time
Site: 07100440, 07109036
Issue date: 06/26/1975
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20010E295 List:
References
NUDOCS 8109030303
Download: ML20010E299 (2)


Text

.'

=

U.S. ATOMIC FNE RGY CoMvlSSioN

' i:SN ' '

CERTIFICATE OF COMPLIANCE t

M ('[g'3 For Red osetivsi Materials Packsnes l

1 1s. Cer t.f acats Num.ser

10. Revesenn No Ic. Pactoge toentification No.

Id.' Pege No.

le. Totat No pay 9036 0

USA /9036/R 1

2 2 PRE AUbiE i

l 2a.

1 h s eertif,caic is issued to satisty Sect.nns 173 393 173 H4. I'3 395. and 173.336 of the Desurterent of,Treesnomt on Hara* ;.'

Maiena s Res;u anons (49 CF A 170-109 and 14 CF P 103t and Secoon 146-10-10s and 146-19-100of the Departenent of Tea s;c tr e-r r

Dangerous Cargoes Regulaf. ors (46 CF A 146-143),as amended 2b.

The packag<ng and contents descriued in item 5 below, rnetts the sefety standards set forth an sut'm's C o' Title 10. Ct.::s o' F e:

a*

Regu ations. Part 71.**Facsag.ng of Rad oactive Materest for Transport and Transportation of Redeoact.ve Material Un :* Cc ta a r

Cond> t io n s "

I i

2c.

This cersif.cate does not ret. eve the consignor from compt.ance v th any reauirement of the regulations of the US. Depa tment c' i

Transportet.on o' other appbcable regutato'y agencies,includ'ng the go e nment of any country through or into wn.ch tre N:n ay will be transported

3. This cc'tificate es.ssued on the baus of a safety ana'ysis report of the pack.ege design or oppt. cation-(2) Tit e end ident f cation of report or opplication:

(1) Pregxtred by (Name ancf address 1:

l Source Production & Equipment Co.

Source Production & Equipnent Company application 625 0xley Street dated January 23, 1975, as supplemented.

Kenner, Louisiana 70062 (3) Docket No. 71-9036 4 CONDiTeoNs Th s cartificate is cond tional upon the fu fninn of the requ.remenis t ' Swepa's D cf 10 CFR 71,se og placabte.and the cones I cas me: *.

e in stem 5 beton.

5. Dence.pt on of Tach sping and Author 7ed Contents. Model Nvrf.ber, F #sute Class. Onhee Conditions, and hetereres (a )

Packaging (i) flodel No. :

C-i (2)

Description A uranium shielded radiographic source changer.

Configuration is that of a rectangular tox 4" high x 7.5" wide x 7" deep.

All fittir gs and source locking components are protected and enclosed within a 1/8" carben steel cuter shell.

The inner rcrentacle consists of a ure-ir shield equinned with two closed botte:1 iircalny "J" tubes, each of mir nay house orc "p'igtail type" special forn source, llaxinun grcss vaight is 45 lbs.

(3)

Drawings l

l The package is constructed in accordance with the Source Producticn f.

Equipnent Company drawings as submitteo in the cpplication and supplement dated January 23, 1975 and liay 7,1975,. respectively.

Appendix H 8109030303 810817 PDR ADOCK 07100440 C

PDR

p Page 2 - Certificate No. 9036 - Revision No. 0 - Docket No. 71-9036 5.

(b)

Contents (1) Type and form of naterial Iridium-192 as sealed sources that meet the requirements of special forn as defined in 571.4(o) of 10 CFR Part 71.

(2)

Maximum quantity of material per package Two sealed sources with a combined activity not to exceed 200 curies.

6.

The nameplate shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining its legibility.

7.

The package authorized by this certificate ;a hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.

8.

Expiration.cate: June 30, 1980.

REFERENCES Source Production & Equipment Cenpary applicaticn dated January 23, 1975.

Supplement dated May 7,1975.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

[8(<v Charles E. HacDonald, Chief Transportation Branch Division of Materials and Fuel Cycle Facility Licensing Date June 26, 1975 Appendix H

..