ML20010D154

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Jul 1981
ML20010D154
Person / Time
Site: Farley 
Issue date: 08/01/1981
From: Hairston W
ALABAMA POWER CO.
To:
Shared Package
ML20010D153 List:
References
NUDOCS 8108240060
Download: ML20010D154 (3)


Text

,.

a OPERATI iG DATA REPORT DOCKET NO. 50-348 DATE 8/1/81 COMPLETED BY W.G.hairston, III TELEPHONE (ZU))69925156 OPERATING STATUS

1. Unit Name: J SePh M. Farley - Unit 1 Notes 1) Cumulative data
2. Reporting Period:

July, 1981 since 12/1/77, date of

3. Licensed Thennal Power (MWt):

2652 commercial operation.

860

4. Nameplate Rating (Gross MWe):
5. Design Electrical Rating (Net MWe): 829
6. Maximum Dependable Capacity (Gross MWe):

844.6

7. Maximum Dependable Capacity (Net MWe):

803.6

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7)Since Last Report.Gise Reasons:

N/A

9. Power Lesel To Which Re tsicted. If Any (Net MWe):

N/A

10. Rea>ons For Restrictions,1f Any:

N/A This Month Yr.-to-Da te Cuhulatise

11. ilours In Reporting Period 744 5,087 32,135
12. Number Of flours Reactor Was Critical 744 2,840.8 20,023.1
13. Reactor Reserte Shutdown !!ours 0

374.1 2,820.9

14. Ilours Generator On.Line 744 2,670.6 19,374.0
15. Unit Reserve Shutdown Hours 0

0 0

16. Gross Thennal Energy Generated (MWH) 1.889.655.9 J,500,017.8 48,489,909.6
17. Gross Electrical Energy Generated (MWH) 590,366 2,052,874 15,472,282
18. Net Electrical Energy Generated (MWH) 558,978 1 911,386 14.519,136
19. Unit Service Factor 100.0

_ 52.5 60.3

20. Unit Availability Factor 100.0 46.8 56.2 52.5 60.3
21. Unit capacity Factor (Using MDC Net) 93.5
22. Unit Capacity Factor (Using DER Net) 90.6 45.3 54.5
23. Unit Forced Outage Rate 00.0 10.8 07.5
24. ShutdownsSchedated Oser Next 6 Months (Type.Date.and Duration of Each):

Maintenance / Design Change Modifications associated with TMI-2; Mid-September, 1981; Anoroximately 2-3 weeks.

25. If Shur Down At End Of Report Period. Estimated Date of Startup:

N/A

26. Units In Test Status (Prior to Commercial Operation):

Forecast Achiesed INITIA L CRITICA LITY 8/6/77 8/9/77 INITIA L ELECTRICITY 8/20/77 8/18/77 COMMERCIAL OPERATION 12/1/77 12/1/77-8108240060 810817 PDR ADOCK 05000348 R

PDR (u1771

AVERAGE DAILY UNIT POWER LEVEL

+

,/

50-348

,. ' ~

DOCKET NO.

~

t UNIT 1

DATE 8/1/81

~

N

  • C' II"I E III NLETED BY

,t TELEPHONE (205) 899-5156 MONTl!

July. 1981 DAY AVERAGE DAILY POWER LEVEL

  • DAY AVERAGE DAll POWER LEVEL (MWe-Net)

(MWe. Net) 411

~778 1

17 781 775 2

IS 789

~

786 3

39 4

722 20 785 3

593 786

.1 4

6 654 785 3

7 777 23 786 m

i 782 g

783 y

1 9

784 25-731

~ --

10 780 26 704

~

gg 780

T 774 J,.,

12 769

,, 23 779 13 773 780

~. -

3 14 755 783 30

33

'784

. 15 767

-775 16

~

INS 7RUCDONS On this formst. list the average daily unit power level in MWe-Net for c:ch d:y in the reporting month. Compute to the ne: rest whole meg: watt.

%g e

p t

m 7-

D UNIT SIIUTDOWNS AND POWER REDUCTIONS DOCKET NO.

50-348 UNIT NAME J.M.Feirley-Unit [

DATE _ R /1/R1 REPORT MONTil July, 1981 COMPLETED BY U.C.HMrston. III TELEPilONE (705)R99-5156 "E

e ei

.3 no :

5

.2 _e E

,.s X Licensee cg

-o

$.'3 cL Cause & Corrective a

No.

Date g

3g g

jg5 Event u?

Action to

$5 5

j di g Report e iN0 5O Prevent Recurrence H

6 018 810701 F

0 G

4 N/A RB ZZZZZZ Continuation of Power reduction from 6/30/81 due to accumulation of 72 penalty points for axial flux differ-ence (AI) being out'of target band during power ascension.

019 210704 F

0 A

4 N/A RB INSTRU Unit power reduced to and held at less than.'5% (639 Mwe) due to indicated Quadrant Power Tilt Ratio exceeding Tech. Spec, limit (QPTR-1.07). Recalibrated NIS fol-lowing verification that QPTR had not.

exceeded Tech. Spec. limit.

020 810725 S

0 B

4 N/A HB INSTRU Unit power reduced to and held at 33%,(205 MWe) to place flow trans-mitter FT-426 back in service.

I 2

3 4

1: 1 orced Reason:

Metliod:

lixhibit G. Instinctions S: Scheduled A liquipment Failure (Explain) '

l. Manual for Preparation of Data ll Maintenance of Test 2.Manu.il Scram.

I?ntiy Sheet > for I.icensee C. Refueling

3. Automatic Seram.

Event Report (LliR)l ile (NUREG.

D. Regulatory Restriction 4 Other(Explain) 0161)

E. Operator Training & License lixamination 1;. Administrative 5

G. Operational Error (Explain)

Exlubit ! Same Source

('l/77)

II.Othes (Fxplain) -

,