Text
.-
'D'ISTRIBUTI0hi:
Docket Files bcc:
LB#1 Rdg.
TERA DEisenhut PDR JYoungblood LPDR
/ JR 3') 1987 GEdison NSIC
/
MRushbrook I
k(U.
Docket Nos. : 50-482, 50-483
',((
and 50-486,/
TMurley nf v
(
g[
f a son 2/
Mr. N. A. Petrick
^
0
~5 60\\
Executive Director o e Cherry Road r. od
.s.
Rockville, Maryland 20850 RBosnak h$1III®IIIl
Dear Mr. Petrick:
IG
Subject:
Use of ASME Code Case N-275 for SNUPPS Projects, Docket Nos. STN 50-482 (Wolf Creek. Unit 1). STN 50-483 and STN 50-486 (Callaway Units 1 and 2)
We have completed our review of the SNUPPS request for authorization to use ASME Code Case N-275 for application in the_ repair of welds for SNUPPS Projects STN 50-482 (Wolf Creek Uriit 1), STN 50-483 and STN 50-486 (Callaway Units 1 and 2), as identified in your letter SLNRC 81-29, dated May 11, 1981.
Code Case N-275, dated May 15,1980, " Repair of Welds,Section III, Division 1,"
ir acceptable subject to the following conditions in addition to those specified in the code case:
If an indication is. removed and weld metal layers remain, the case cannot be used by gouging through the wall.
Instead, in such a situation, examination of the cavity is required when the indication has been removed.
Therefore, Code Case N-275 may be used for application on SNUPPS Projects STN 50-482, STN 50-483, and STN 50-486, subject to the conditions indicated above. Use of the Code Case should be documented in the FSAR.
The SNUPPS request for authorization to use Code Case N-275 also enclosed a letter from Daniel Construction Comoany, DLUC-6207, dated March 9,1981.
It is our opinion that item 3 on page 2 of the. Daniel letter is an incorrect interpretation of Paragraphs NB/NC/ND/NE/NF/NG-4453.1 of the code. Based on the limited information in the Daniel. letter, there may be instances where the repair of weld joint assemblies for the SNUPPS Projects are not.in con-formance with Section III of the code.
Questions may be addressed to the licensing project. manager for the SNUPPS designs, Dr. G. E. Edison.
Sincerely, 8108210172 810730 PDR ADOCK 05000482
. Original siwca by A
PDR p L T mia.a3 O(' !
Robert L. Tedesco, Assistant Director fort 1tenging
-t DL:LBel hl:L; y Ol_ :., / L.
.Di vis. ion..of.. Licensing.
o"'o>
3,,,4 GEdison/lg BJL yod.,,,,,RLT ehco 7/2M11"SupR 3 e" 7/M81"
.k.
ferosuaiuocso.wacuom OFF!CIAL RECORD COPY
= =-3m2.
fU'
~
.ir. J. K. Bryan Mr. Glenn L. Koester Vice President - Nuclear Vice President - Nuclear Union Electric Company Kansas Gas and Electric Company P. O. Box 149 201 North Market Street St. Louis, Missouri 63166 P. O. Box 208 Wichita, Kansas 67201 cc: Gerald Charnoff, Esq.
Shaw, Pittman, Potts, Dr. Vern Starks Trowbridge & Madden Route 1, Box 863 1800 M Street, N. W.
Ketchikan, Alaska 99901 Washington, D. C.
20036 Mr. William Hansen Kansas City Power & Light Cempany U. S. Nuclear Regulatory Commission ATTN:
Mr. D. T. McPhee Resident Inspectors Office vice President - Production RR #1 1330 Baltimore Avenue Steedman, Missouri 65077 Kansas City, Missouri 64141 Ms. Treva Hearn, Assistant General Counsel Mr. Nicholas A. Petrick Missouri Public Service Commission Executive Director, SNUPPS P. O. Box 360 5 Choke Cherry Road Jefferson City, Missouri 65102 Rockville, Maryland 20850 Jay Silberg, Esquire Mr. J. E. Birk Shaw, Pittman, Potts & Trowbridge Assistant to the General Counsel 1800 M Street, N. W.
Union Electric Company Washington, D. C.
20036 St. Louis, Missouri 63166 Mr. D. F. Schnell Kansans for Sensible energy Manager - Nuclear Engineering P. O. Box 3192 Union Electric Company Wichita, Kansas 67201 P. O. Box 149 St. Louis, Missouri 63166 Ms. Mary Ellen Salava Route 1, Box 56 Mr. Tom Vandel Burlington, Kansas 66839 Resident Inspector / Wolf Creek NPS c/o USNRC Eric A. Eisen, Esq.
P. O. Box 1407 Birch, Horton, Bittner & Monroe Emporia, Kansas 66801 1140 Connecticut Avenue, N. W.
Washington, D. C.
20036 iir. Michael C. Keener Wolf Creek Project Director State Corporation Commission Ms. Wanda Christy State of Kansas 515 N. 1st Street Fourth Floor, State Office Building Burlington, Kansas 66839 Topeka, Kansas 66612 4