. APPENDIX M
DOCKET NO: 050-0325
' UNIT: Brunswick 'No. I' DATE: August 1981 COMPLETED BY: Frances Harrisoa OPERATIONS
SUMMARY
BRUNSWICK UNIT NO.1 Brunswick Unit No. I was off the line for~the entire month of July for a planned
+
maintenance outage.
There are 476 BWR and 160 PWR spent fuel bundles in the Brunswick Unit No.1 fuel pool.
J
.j.
8108200093 810810-
, POR ADOCK-05000324 R
.PM h
4 M
y
'm 4
s-m 4
mg
-=M swa
.y
.y o
}
(.
.~
lt;
.=
F
!)
~
-APPENDIX B 2
9 AVERAGE DAILY. POWER LEVEL t
3
~
DOCKET NO. 050-0325 UNIT BRUNSWICK UNIT.l' DATE-08/03/81
' COMPLETED BY FRANCES HARRI'60N TELEPHONE 919-457-9521 4
.JULYL81 i.
.i i
- DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY
- POWER LEVEL j.
(MWE-NETL (MWE-NET) i 1
-8.
17
-8.
i j.
~2
-8.
18
-10.
-3
-9.
19'
-10.
-11.
20
-10.
4 p
t 5-
-12.
21
-10.
t 1~
j 6
-13.
22
-11.
[
7
-14 23
-10.
I' i
j 8
-11.
24
-10.
i j
9.
-7 25
-10.
l i-i
.10
-7.
26
-10.
I r
[
11
-9.
27
-9.
i 12
-8.
28
-9.
j i
i I'
13
-9.
29
-9.
i 14
-10, 30
-9.
' 15
~9 31
-9.
i 16
-10.
t L
i 1
i l.
1.16 - 8 i
+
'f F.
.~A NL -.. -= -
...-...........a..--..-...a.------
._.~.-,..a.-
n
.c l0PERATING' DATA REPORT ~
DOCKET NO.'050-0325~
DATE 08/03/81 COMPLETED BY FRANCES HARRISON TELEPHONE 919-457-952
' OPERATING STATUS-l-
- 1. UNIT NAME: BRUNSWICK UNIT'1 I NOTES I
- 2. REF ORTING PERIOD: JULY 81 I
I.
- 3. L)CERSED THERMAL POWER (MWT):'2436 I
I 4.
NAMEPLATE RATING-(GROSS MWE): 867.0 I
Iz
- 5. DESIGN ELECTRICAL ~ RATING (NET MWE): 821.0 I
I 6.JMAX DEPENDABLE CAPACITY (CROSS MWE): S15.0 -I I
- 7. MAX DEPENDABLE CAPACITY (NET.MWE): 790.6 9.'IF CHANGES.0CCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:
- 9. DOWER LEVCL TO WHICH RESTRICTED IF ANY (NET MWE): NONE
- 10. REASONS FOR.7ESTRICTION IF ANY:
THIS YR TO CUtR'L MONTH DATE ATIVE
- 11. HOURS IN REPORTING PERIOD 744.0 5087.0 38328.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL 39.3 2173.6 25975.7
- 13. RE4CTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1647.1
- 14. HOURS GENERATOR ON LINE 0.0 2056.8 24438.7
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROS; THERMAL ENERGY GENERATED (MWH) 0.0 3841575.6 49965308.5 17.-GROSS ELECTRICAL ENERGY GENERATED (MWH) 0.0 1256185.0 16581779.0
- 18. NET ELECTRICIAL ENERGY. GENERATED (MWH)
-7182.0 1192167.0 15939601.0
- 19. UNIT SERVICE FACTOR 0.0 40.4 63.8
- 20. UNIT AVAILABILITY FACTOR 0.0 40.4 63.8
- 21. UNIT CAPACITY FACTOR (USING MDC NET)
-1.2 29.7 52.6 2,I. UNIT CAPACITY FACTOR (USING DER NET)
-1.2 28.5-50.7
- 23. UNIT FORCED OUTAGE RATE 0.0 8.3 17.4 24 SHUTDOWNS SCHEDULED OVER'NEXT 6 MONTHS (TYPE, DATER At:D DURATION OF EACH):
25.-IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP:
9/25/8'
- 26. UNITS IN TEST STATUS (PRIOR TO COMMERICIAL OPERATION): FORCAST ACHEIV'D INITIAL' CRITICALITY INITIAL ELECTRICITY COMMERICIAL OPERATION 1~.16 - 9
m p, - -_ -
- r. -
V b
b DOCKEINO.
nso nvis UNIT SIIUTDOWNS AND POWER REDUCT10NS UNIT N AME arunswick i DATE Aucust 19R1 COMPLETED BY F"' " "
"*""i=on REPORT SiONT., July 19R1 TELEP!IONE (919) 457 4991
~.
E E
Cause & Cortcetive y'^],
E
.$ g 3
42E Liecnsec
, r, Action to c.
i No.
Date 73 2 4
E E E~
Event u?
gG EO Prevent Recurrence js u
3.3 Report #
6
- e
~
S 744 B
1 N/A Itaintenance Outape l
I s
! 1 l
i 3
4 Exhibit G Instructions 1
2 Alethod:
F: Forced Reason:
1 -hf anual for Preparation of Data S: Scheduled A.I~quipment Failure (Explain) 2-Manual Scrarn.
Entry Sheets for Licensee 11 Maintenance of Test 3 Automatic Scram.
Esent Report (LER) File (NUREC.
4 C Itefuelmg 4 Continuations 0161)
D.Itegulatory Itestriction E Operator Training 1 License Examination 5-Load Reductions 3
F-Administrative 1
6-Other Exhibit 1.Same Sourec C. Operational Error (Explain)
[
- 9/77) liother(Explain) i
.~
- t..
OPERATING. DATA' REPORT DOCKET NO. 050-0324
~DATE 08/03/91 COMPLETED BY FRANCES HARRISON.
TELEPHONE 919-457-9521.
a OPERATINGjSTATUS 1.. UNIT NAME: BRUN9 WICK UNIT 2 I NOTES I
4
- 7. REPORTING PERIOD: JULY 81 I
I
- 3. L JCENSED THERMAL POWER (MWT): 2436 I
. I-4.
NAMEPLATE RATING (GROSS.MWE): 867.0 I
I
'5. DESIGN ELECTRICAL inifNG (NET MWE): 921.0 I
I
- 6. MAX DEPENDABLE CAPACITY-(GROSS MWE): 815.0 I I
- 7. MAX LEEPENDABLE CAPACITY (NET MWE): 790.0
------------------~~
8.
IF CHANGES OCCUR IN CAPACITY. RATINGS (ITEMS 3 THRU 7) 52NCE LAST REPORT,
~
GIVE REASONS:
I
'9 POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE): NONE
- 10. RE950NS FOR RESTRICTION IF ANY:
THIS YR TO CUMUL MONTH DATE ATIVE
- 11. HOURS IN REPORTING PERIOD 744.0 5087.0 50352.0
'12. NUMBER OF HOURS REACTOR WAS CRITICAL 505.3 2724.4 31746.7'
- 13 REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 1/
HGURS GENERATOR ON LINE 443.6 2447.2 29411.5.
- UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 o.
GROSS THERMAL ENERGY GENERATED (MWH) 775438.1 4033239.2 53644620.1 1
.7.
GROSS ELECTRICAL ENERGY GENERATED (MWH) 137571 0 1364545.0 17928991.0 l
id. NET ELECTRICIAL ENERGY GENERATED (MWH) 244569.0 1290837.0 17196266.0
- 19. UNIT SERVICE FACTOR 59.6 48.1 58.4-
- 20. UNIT AVAILABILITY FACTOR 59.6 48.1 58.4
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 41.6 32.1 43.2-
.2.
UNIT CAPACITY FACTOR (USING DER NET) 40.0 30.9 41.6 2
- 23. UNIT FORCED OUTAGE RATE 40.4 S0.0-
.18.3 24.-SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
- 25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP: ~0/ 0/ 0
- 26. UNITS IN TEST STATUS (PRIOR TO COMMER1CIAL OPERATION): FORCAST ACHEIVED.
1NITIAL CRITICALITY INITIAL ELECTR: CITY
-COMMERICIAL OPERATION 1
1.16 - 9
^^
~
. t,,-
~
APPENDIX B AVERAGE DAILY POWER LEVEL l
l, DOCKET NO. 050-0324
['
~ UNIT BRUNSWICK ~ UNIT-2 l
DATE 08/03/81-ij *'c COMPLETED BY FRANCES.HARFISON l
. TELEPHONE 919-457-9521 l'
l l
TVULY181 i-f.
DAY AVG. DAILY POWER LEVEL DAY AVG. DM Y POWER LEVEL (MWE-NET)-
-(MWE-NET) l l-1-
'682.
17 623.
I 2
46.
19 142.
3 192.
19
-15.
4 534.
20
-14.
5 660.
21
-14.
6 663.
22
-13.
7~
674.
23
- 1 ~2.
3 8
661.
24
-11.
9 654.
25
-12.
I 10 670.
26
,3.
i 11 82.
Zi
-11.
12
-4.
28 258.13-414.
29 353.
14 608.
30 413.
.j
- S 669.
'31 675.
16 634.
l' 1.16 I f
Iw--..------.:--
---.=---
\\
APPENDIX DOCKET NO: 050-0324 UNIT: Brunswick No. 2 DATE:
'.ugust 1981 COMPLETED BY: Frances Harrison OPERATIONS
SUMMARY
BRUNSWICK LHIT NO. 2 Brunswick Unit No. 2 operated at a 59.6% availability factor for the montt. of July with 41.6% capacity factor. There were three "off-line" outages this month, they are detailed in Appendix D, the unit shutdowns and power reductions log.
There are 264 BWR and 144 PWR spent fuel bundles in the Brunswick Unit No. 2 fuel
- pool, w
r UNIT SilUTDOWNS AND POWER REDUCTIONS h E f.,h Brunsu e ?
DATE A"R"St 1981 -
Frances tiarrison COMPLETED BY July 1981
( 919)4ai-n21 REPORT MONTil TELEP!!ONE Licensee
[-r, h.
Cause & Corrective
.$ g 3
.7h No.
Date c-E i
E E J~
Event
?
c-3 Action to rN 0
$O Prevent Recurrence 5s e
3 di Report -
u e
C 81-019 81/07/03 F
32.8 B
3 N/A CD VALV0P Failure of.2-B21-F022C MSIV (inboaru) disk separated from. stem. Outage was extended because of loss of feedwater codtrol.
Shut 2-B21-F028C, hung Shift Foreman's clearance on both F022 & F028G.
Repressurizing to reactor pressure
-s prior to valving.
k I
4 3
I 2
Method:
Exhibit G. Instructions F: Forced Reason:
1 M.mual for Pseparation of Data S: Scheduled A l'qmpment liilure (Explain) 2 Manual Scrarn.
Entry Sheets for Licensee n Mainte unee or Test 3 Automatic Scram.
Esent Reper 'LERI Fi:e(NUREG-C Refueling 4 Continuations 0161)
D Regulatory Restrietion E-Operator Trainmga Licenw Examination 5-Load Reductions 5
F-Administrative 6-Other Exhibit I-Same Souree G Operational Error (Explain) l i
(9/77)
Il Other (Explain) 4
y y
-w j
e p
~
p n.
DOCKET NO.
050-0Us UNIT SilUTDOWNS AN9 POWER REDI.'CTIONS UNIT NAME T ri m eA <-t-9 DATE Anonne 1991 COMPLETED BY _ Frances p,rrhon
( 91914 57-o c;?1 July 1981 TELEPl!ONE REPORT MONTil 1
Cause & Corrective
.? ?
?'
Licenscc f n.,
1, N**.
Date i
5-4
.3 y J Event sy c3 Action to
~:,
NV Prevent Recurrence H
$5 rE I: 5 Report #
u c-c.81-020 81/07/1L 1
40.2 A
3 N/A Outage cause being invastigated by Engineering
}
~
r r I
3 4
Exhibit G-Instructions I
2 Method:
for Preparation of Data F: ForecJ fleason.
- 1. Manual S: Scheduled A 1 qmpment railure (E-ain) 2 Manual Scram.
Entry Sheets for Licensee 11 Maintenance of Test 3.Aurumatic Scram.
Esent Report (LER) File (NUREC.
C Itefuehng 4 Continuations 0161)
D Itegulatory liestriction E Operator Training & License Examination 5-Load Reductions I
F Adnnnistrative 6-Other Exhibit ! Same Sourec G Operational Error (Explain)
($1/77)
It Other (Exr. lain)
n
?
/
g.
O f
. /'}.
050-0325 DOCKET NO.
UNIT SliUTDOWNS AND POWER REDUCTIONS UNIT N A*.lE Brunswick 2 DATE August 1981 COMPLETED BY Francac u,rricon REPORT MONTil July 1981 TELEPliONE (otous7 out
~
E 4.2, 5 e. ~4 Licensec
,E g o.
E*
Cause & Correetive q
.5 ?
E No.
Date g
3g g
,g y 5 Event
- t y c3
/.etion to H
$5 5
3i5 Report -
'N U
$U Prevent Rscurrence o
e d.
~
81-021 8/07/81 F
227.4 A
1 N/A CD VALV0P MSIV Repairs Removed and repaired stem disc assembly and ensured stem and
, disc were pinned properly a
s 1
2 3
4 F: Forced Reason:
Method:
Exhibit G -Instructions S: Scheduled A Fquipment Failure (Explain)
- 1. Manual for Preparation of Data
[1 Maintenance of Test 2 Manual Scram.
Entry Sh:ets for Licensee 3-Automatic Scram.
Event Report (LER) File (NUREG.
C Refueling D Regulatory Restriction 4 Continuations 0161)'
E-Operator Training & License Examination 5-Load Reductions 5
F-Admimstrative 6-<)ther Exhibit I Same Source G Operational Error (Explain)
(*)/77) li-Other (Explain)
-