ML20010A950

From kanterella
Jump to navigation Jump to search
Forwards Updated LER 81-011/03L-1
Date released: 01/24/2020 Download: ML20010A950


Updated LER 81-011/03L-1:on 810121,reactor Recirculation Sample Inboard Isolation valve,1-B32-F019,Model T36D-1B, Had Seat Leakage of 0.25 Gpm.Caused by Minor Scratches Due to Normal Use.Valve Seat Lapped
ML20010A953
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 08/05/1981
From: Pastva M
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20010A953 (1)
Forwards Updated LER 81-011/03L-1
ML20010A949
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 08/05/1981
From: Dietz C
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20010A949 (1)