SURVEILLANCE REQUIREMENTS 4.6 CONTAINMENT SYSTEMS 4.6.1 PRIMARY CONTAINMENT CONTAINMENT INTEGRITY 4.6.1.1 Primary ^0NTAINMENT INTEGRITY shall be demonstrated:

a.

At least once per 31 days by verifying that:

1.

All accessible (per occupational exposure considerations) penetrations not required to be open per approved orocedures during RECOVERY MODE are closed by valves, blind fianges, or deactivated automatic valves secured in their pocitions.

2.

The equipment hatch is closed and sealed.

b.

By verifying that each containment air lock is OPERABLE per Specification 3.6.1.3.

~

CONTAINMENT AIR LOCKS 4.6.1.3 Each containment air lock shall be demonstrated OPERABLE:

a.
  • After each opening, except when the air lock is being usert for multiple entries, then at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, by verifying less than or equal to 0.01 L seal leakage when the volume between the door seals is stabilize to a pressure to 10 psig.

I b.

At least once per 6 months by conducting an overall air lock leakage l

test at P,L=. is within its limit., 56.2 psig, and by verifying that the overall air lock leakage r.

It1TERNAL PRESSURE 4.6.1.4 The primary containment internal pressure shall be determined to within the limits at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

l

l THREE MILE ISLAND - UNIT 2 4.6-1 l

0108120263 010aos PDR ADOCK 05000320 P

PDR

SURVEILLANCE REQUIREMENTS AIR TEMPERATURE 4.6.1.5 The primary containment average air temperature shall be the arithmetical average of the temperatures at the following locations and shall be determined at least once per 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:

Location RB nominal Elev. 350' (1 temperature indication)

J a.

b.

RB nominal Elev. 330' (1 temperature indication)

RB nominal Elev. 305' (1 temperature indication) c.

l 4.6.4 COMBUSTIBLE GAS CONTROL l

HYDROGEN ANALYZERS 4.6.4.1 The gas partitioner shall be demonstrated OPERABLE at least once per 31 days by perfo. ming a CHANNEL CALIBRATION using sample gases containing:

a.

One volume percent hydrogen; balance air.

1 b.

Four volume percent hydrogen, balance air.

i dYDR0 GEN PURGE CLEANUP SYSTEM The hydrogen purge ci anup system shall be demonstrated OPERABLE:

4.6.4.3 v

At least once per 18 months or (1) after any structural maintenance I

a.

l on the HEPA filter or charcoal adsorber housings, or (C) foilowing l

painting, fire or chemical release in any ventilation zone communi-cating with the system by:

1.

Verifying that the cleanup system satisfies the in place testing acceptance critaria and uses the test procedures of Regulatory Positions C.5.a, C.S.c and C.S.d of Regulatory Guide 1.52, Revision 2, March 1978, and the system flow rate is 1000 cfm i 10%.

2.

Verifying a system flow rate of 1000 cfm i 10% during system operation when tested -in accordance with ANSI N510-1975.

b.

At least once per 18 months by verifying that the pressure drop across the combined HEPA filters and charcoal adsorber banks is less than 6 inches Water Gauge while operating the system at a flow rate of 1000 cfm 10%.

THREE f1ILE ISLAND - UNIT 2 4.6-2 Change No. 6

4 -

  • e ur. Gale noven metrepeitten Edison Company Mr. J. J. Sartan us Kathy RCaughts manager. $tte Operations. TMI.2 Three Rtle Island Alert. Inc.

metropelttan Edtson Company 23 South list $tmt P. O. Ses a60

    • ""*"'8
  • P A U104 noddletown, P4 17057 us, marjorte M. Aamodt nr. E. D. Fulle,
8. D. t$

TRI.2 Ltcenstag Supervin, Castessme. PA Ig320 nutropelttan E41sen Company P. O. Ses 480

"$hel"*o"s, herunn. Aotseen & Weiss

  • d Niedletown, PA 17057 172$ I $treet, N.W., Sette 506 ny, g, g, gag gg, essatngton DC 20n6 PWA Licens'ng Ranage, GPU 5er '..e Corporetten

':'M Ce2"Cmi,ssion-

,",,!;;;;; :/ ;;;::

0camp,e Co.t, C.,t,ouse

-t au ~~i t~t

.. J. g. v,i,e-a, E,e v.,e

-~. PA mm se

.er.l... is seis, o r

e 26 r.a Government Pubitcations Section new fort, af 10004

$ tate af Library of Pennsylveste tes Ital Educatten tutletag nr. E. F. Trowertege. Esquire Nantsnurg, PA 17127 Saaw, Pittman Potts & Trownctege 1000 N $treet, N.W.

Dr. Ee.ard O. $= rts Wasntagton OC 20036 Board of Supervisors Londonderry TownshtP Dr. Walter n, Jorden AFD #1 Geyers Churcn Road est u Outer Ortve Ntedletause, PA 17057 Oak Stege. T4 37830 U. $. Enstreamental Protection Agency Or. Linde W. Little 5000 per.itage Ortoe aegten ll! Office Raleigh. RC 27612 ATTil: Ef5 Caerdinator Curtis Butiding ($tsth Floor) tarts W. Carter. Esquire 6th and usinut $treets SOS Esecettve nouse Patladelpnta. PA 19106 P. Q. Ses 2357 narcisburg. PA 17120 Osupnte County Office Emergency Preparedness

.morable Mort Cohen Court Neptge. Itoon y Front and Merket Streets 512 E-3 Mata Capttal Sutiding herrtsburg, PA 17120 Harristurg, PA 17101 Department of Enviernmental Resources Ellyn wetss. Esqusre Sheldar ruen Rotsman a wetss ATTE: Director Office of 1725 I st, N.W., Suite 506 Radiological Mealth Wasataston, DC 20006 P. O. Bos 2063 warrtsburg. PA 17105 nr. $teven C. Shelly 6uvernor's Office of State 304 $. Martet Street Planning and Develesment mechentesburg. P4 17055 ATTII: Cooresnetor. Pennsylventa Clearingneuse nr. Thomas Gerusty P. 6. Ses 1323 Bureau af Radtation Protection Harrisaurg PA 17120 P. O. los 2063 narciseurg, PA 17120 nrs anoda D. Carr 1402 Marene Ortwe nr. nervin I. Lewis Merrisburg, PA 1710g 6504 trasford Terrace PattadelpMa, P4 Igl4g Mr. Atchard Roberts The Patriot us. Jane Lee 412 neraet $treet

t. D. 3. Bos 1521 nBrrisburg. 74 11105 Etters PA 1731g Mr. Robert 8. Sorsum Walter W. Cohen, Consumer Advocate Gatcock & Wilcos Department of Justice nuclear Power Generetten Division Streweerry Square,14th Floor

$ ite 420, 7735 Old Georgetowe Road Harrisburg, PA 17127 Setteses. PC 20014 Socert L. Kaupp, Esqutre Ivan W. $sith Esquire Asststant $olicitor

    • Guic Safety and Licensing Board Kaupp and Andrews U.1. Nuclear Regulatory Commissten P. O. Bos P wasnington. DC 20555 a07 R. front $treet Herrtseurg, PA 17108 Ateste Safety and Licensing Board Panel W. 5. nuclear segulatory Cometssten John E. Minnich, Chatroerson Washington DC 20655 Davents Co. goard of Comerisstoners Dewonin County Courthouse front and Market Streets Ateetc gefety and LtCenstag Appeal Penei narressurg, PA 17101 U. 5. Rutlear Aegulatory Commission hasa:ngton, DC 20555 notert O. Pollard

- Ches. peat Energy Alliance Cortating and Service lection tog montpelter Street

u. $. auclear segulatory Camelssten Baltteore, pc 21210 mosainta,n, DC 20555 s s.uncey tesford audith M. JohnsrM4 Mies Lochstet Eevirorumental scelttien on nuclear Pthser 433 Ortenee Avenue

,I F 8 State College. PA 1680%

untvorsity Part. Pennsylvente ledet us. Friede terryntil. Chatepersen ytr9 ata Southard, Chelemen t

Coelttion for nuclear Pouer Plant Postponement Lit 12ess for a Safe Enstegreent 264 malton Street 2610 Grenoon Drive utletagton DE 19608 Lemeyne. PA 17043 Holly $. Eect enti.pheclear Group Representing fort 245 W. riitisaelonia Street fort, #A 17404 John Levin Eseutre Pennsylvente Putlic Utilitias Ceresission P. O. los 3265 warrisburg. PA 17120 runningher. Esquire Jereon v Fos. Farr and Cunningham 2320 4. Secone $treet Herrisburg, P4 17110 r

- - -,