ML20009G615

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 50-285/81-15 on 810615-18.No Noncompliance Noted
ML20009G615
Person / Time
Site: Fort Calhoun 
Issue date: 07/10/1981
From: Seidle W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: William Jones
OMAHA PUBLIC POWER DISTRICT
Shared Package
ML20009G616 List:
References
NUDOCS 8108040478
Download: ML20009G615 (2)


See also: IR 05000285/1981015

Text

v

NS

N

NnL GO

.

%

w

4

A

5

W

G

G.

CO

10 tagg

In Reply Refer To:

RIV

Docket: 50-285/81-15

3

-

I'Q

p/ 9 n [ [~ fh h h

/*

%

Omaha Public Power District

b~

ATTN: Mr. W. C. Jones, Division Manager

O ' O O 881 A 6

g;

bko.,iS'#CymnM/

'

Production Operations

1623 Harney Street

(

Omaha, Nebraska 68102

(f/

/'

y/

Gentlemen:

'

y

-

This refers to the inspection conducted by Mr. J. P. Jaudon of our staff

during the period June 15-18, 1981, of activities authorized by NRC Facility

Operating License DPR-40 for the Fort Calhoun Station and to the discussion

of our findings by the inspector with Mr. K. J. Morris and other members of

-

your staff at the conclusion of the inspection.

<

Areas examined during the inspection and our findings are discussed in the

enclosed inspection report. Within these areas, the inspection consisted of

selective examination of procedums and representative records, interviews

with personnel, and observations by the inspector.

i

Within the scope of this inspection, no violations or deviations were identi-

fled.

,

Three new unresolved items are discussed in paragraph 3 of the enclosed report.

Even though no citation is included in this report, our review of previous

inspection histo'y at Fort Calhoun Station, coupled with observations included

in paragraph 3 of this report, indicates what appears to be a generic problem.

i

The timeliness, tmount, and quality of engineering support provided Fort

Calhoun Station appear to be insufficient. The babklog of outstanding design

changes, the problems with identifying appropriate test requirements, and the

chronic deficiency with drawing revision indicate what appears to offer the

potential for a violation of Consission requirements governing design change

control. Please respond to this letter to indicate the results of your review

of this area, and any actions which you will take to rectify this apparent

Tb

5

problem.

In particular, your response should delineate measures that will be

taken to establish control over the design change process and to assure timely

jj

and sufficient engineering support for the Fort Calhoun Station.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter and the enclosed inspection report will be placed in the NRC's

Public Document Room.

If this report contains any infomation that you

.

!

believe to be exempt from disclosure under 10 CFR 9.5(a)(4), jt is necessary

i

,mc,p

gat you (a) notify this office by telephone?within 10 days

1 the dJte of

W

.

...y.........

~ . p.S 2-

~RPB~ W

. E l B. ~ .

Y,RIN.. .

c

. D.H. .u. n n.Q. .u tt. .

g g.ypy- - . ~,qgs= ,

..

.

Same> , ,a u. don.:.b. .b. . .

4. . .". .R. Ha.l l

. . .C. .S. e. i . . .. ..

Col .l.i.n s

'

.G. .L. M. .a ds.j . .n . . .

.

e

.

ic

.

. .

j.g g

g

.

l

8108040478 810710

fo f/

'"

' *

  • * *
  • "
  • * * " *

'" * * * "

" "*""'

\\

PDR ADOCK 05000285

PDR

usac e

e

l'*C' .G

_ __ , _

OFFICI A,L R ECOR_D_ COPY

.

__

_

_

s.

,

i

.

-

.

,

.

p lO'b

Omaha Public Power District

2

,

.

_

this letter of your intention to file a request for withholding; and (b) sub-

mit within 25 days from the date of this letter a written application to this

office to withhold such information. If your receipt of this letter has been

i

delayed such that less than seven days are available for your review, please

notify this office promptly so that a new due date may be established.

Consistent with Section 2.790(b)(1), any such applicatfun must be accompanied

by an affidavit executed by the owner of the infomati 1 which identifies the

'

doctament or part sought to be withheld, and which contains a full statement

of the reasons on the basis which it is claimed that the infomation should be

withheld from public disclosure. This section further requires the statement

to address with specificity the considerations lisi.ed ir, 10 CFR 2.790(b)(4).

The infomation sought to be withheld shall be incorporated as far as possible

into a separate part of the affidavit.

If we do not hear from you in this

4

regard within the specified periods noted above, the report will be placed in

the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased

to discuss them with you.

Sincerely,

'

(s)

W. C. Seidle, Chief

Engineering Inspection Branch

Enclosure:

IE Inspection Report 50-285/81-15

cc w/ enclosure

S. C. Stevens, Manager

Fort Calhoun Station

!

P. O. Box 98

Fort Calhoun, Nebraska 68023

bec to Document Management Branch

bec distributed by RIV D rf")

for distribution Ned/

Nebraska State Dept. of Health '

Kansas State Dept. of Health

AD/RCI (Reinmuth)

IE Files

Standards Development

ELD

NRR (9 Cys) 2_/

,

AE0D

,

-

PDR

, , ,,

,,,

,,

,

,,, , ,,,,

,

, , g,,

EIB

DD-RIV

STS-WPU

STS

PS2

RPB

!

"'C 4 ..........C...

, ,

,,,, ,,, ,

,,,,,,

->

...uauon.;.bb.

..R.Ha.u........

DHu,nnicu,tt,,

->

..?/af81

.. 7f . f81

. ?/ t /816

,,,M/,/81

dsen,,,

,y,CSe,id,],e,,

.)lCo,W ns,.,

........ .... ...

. 7/

..?/ /81

..?f. ./81

. ..

. ...

. . . . . . . ,

............. .. .

. . . . .

.

..

. .

..

,.

' ' " " " "

OFFICIAL RECORD COPY

L nac ronu m '

_