ML20009G069

From kanterella
Jump to navigation Jump to search
Forwards LER 81-080/03L-0.Detailed Event Analysis Encl
Date released: 01/23/2020 Download: ML20009G069


LER 81-080/03L-0:on 810508,while in Mode 5,initial Fuel Loading,Both Trains of RHR Sys Were Inoperable.Caused by Failure of Personnel to Prevent Entering of Mode 5 W/O RHR Train B Operable.Operating Procedure Will Be Written
ML20009G077
Person / Time
Site: McGuire 
Issue date: 06/07/1981
From: Ouellette R
DUKE POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009G077 (1)
Forwards LER 81-080/03L-0.Detailed Event Analysis Encl
ML20009G068
Person / Time
Site: McGuire 
Issue date: 06/05/1981
From: Parker W
DUKE POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009G068 (3)