05000260/LER-1981-033-03, /03L-0:on 810702,reactor Low Pressure Permissive Switch for Recirculation Pump Discharge Valve Actuation Switch 1 Failed.Cause Unknown.Switch Freed & Exercised to Verify Operability.Considered Random Failure

From kanterella
(Redirected from ML20009F969)
Jump to navigation Jump to search
/03L-0:on 810702,reactor Low Pressure Permissive Switch for Recirculation Pump Discharge Valve Actuation Switch 1 Failed.Cause Unknown.Switch Freed & Exercised to Verify Operability.Considered Random Failure
ML20009F969
Person / Time
Site: Browns Ferry 
Issue date: 07/23/1981
From: Holder G
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20009F964 List:
References
LER-81-033-03L-01, LER-81-33-3L-1, NUDOCS 8108030203
Download: ML20009F969 (2)


LER-1981-033, /03L-0:on 810702,reactor Low Pressure Permissive Switch for Recirculation Pump Discharge Valve Actuation Switch 1 Failed.Cause Unknown.Switch Freed & Exercised to Verify Operability.Considered Random Failure
Event date:
Report date:
2601981033R03 - NRC Website

text

.

U. S. NUCLEAR REGULATCRY COMMISSION TC FORM 36h J

LICENSEE EVENT REPORT

77) '-

t.ON iltot lit 00..

l l

l l

l l

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI J

o

~QTj l ^ l I.] 15 ] Il l le ] 2 lglIts0 l 0 l -l 0 l 0l 0 l 0 l 0 l - l 0 l 0 [gl 4 l 1 l 1 l 1 l 1 lgl 7 LAT b6 l

15 16 L4 CENSE TYPE JO 6

L80LNbL NUMtlkH i4 as s iiLLN;aLL CUl#L 0181 3[nCE l I'l@l 0l 5 l 0l 0 l 0l 2l 6 l O gl 0 l 7 l 0 l 2] 8 l ll@l 017121318 l l l@

om r 68 69 EVENT QATE 74 75 REPORT D ATE 80 60 61 OOCKET NUM8ER H'

EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h a 12 l,1 During normal operation, while performing routine surveillance tests (SI 4.2.B-7),

l 2-PS-68-96 switch number 1 failed to operate.

(T.S. Table 3.2.B).

This switch is n,,3, l

l a reactor low pressure permissive for recirculation pump' discharge valve actuation.

l oiAi Redundant systems were g

[ There was no danger to the health or safety. of the public.

n i.,.

Previous similar event: BFRO-50-260/78018.

g JoI. 1 l available and operable.

i TTT-l l l

io lu i f E

ODE SUSC E COMPONENT CODE SU8 OE SU E

l Cl El@ ]@ l B l@ l 1 l N l S l T l R l U l@ ]Q ] @

lo l 91 a

9 10 11 12 f3 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION EVENT YEAR REPORT NO.

CODE TYPE No.

l l1l l--j lOl313l d

1013 l [LJ b

W LE R/RO

@ gUQE RE R

,,,, 21 22 23 24 26 27 28 29 30 3

32 T

N AC P NT MET HOURS S8 i FOR 8.

SU LE

  • MANUF RER Laj@Lz.J@

LI.J@

LzJ@

l o l 0 I 0101 ' LYJO I N [@

W@

lBl0l8l0l@

J3 J4 JS 36 3

40 48 42 43 44 47 1

CAUGE DESCRIPTION AND CORRECTIVE ACTIONSThe Barton, bellows type, pressure switch, model 288 g I i l o j l Stuck switch - reason unknown.

iiiij i was freed, exercised a number of times to verify switch operability, and surveillance instruction 4.2.B-7 was satisfactorily completed. This is considered a random

, i,i i 1',Igl failure and no further recurrence control is required.

l l

l I

LL.Lij l 80 11 a

')

l YTNtf[

% POWER OTHER STATUS OtS Y

OlSCOVERY DESCRIPTION Routine test l

li 151 [Jjh l 0l 9 l 8l@l NA l

lBlgl A2nve rs co$rtnr d

LOCATION OF RELEASE iis't.k Asko or nEll A.F AMOUNT OF ACTIVITY NA l

l NA l

lilr.) W @ d @l f'

pe ne.oNNe$. rv e<nuIitS l t i / l l 0 l 0'l 0 lhlrvaeZ lh[cESCniefiON h l

90eni n NA l

ctwsonse'i.'imau' dies oc;cnianosh NA j

nuunt n

'lii*ll0l0l0l@l 80 i

s 11 17 t OL3 t)f OH I)AMAt.E TO F ACIL1TV fvPE DESCIHPftnN NA l

lil'il W hl

$0Soo! BON NRc usE ONov

'W h.UEi@l Escni,nON @

o

'"""' '7 PDR

; ; ;;;;;;;;;l.

S 68 69 80 5 lt 4

3 in o

Gene Holder (205) 729-6134 PHONE:

NAME OF PREPARER

a E _.... _

Form liF 17

'Tenrn:..cc Vallev :\\ut h..

it y BF 15.2 Brosvin. Iterry N o r te:o l' hut G/04/81 1 F.l; SUl'l LF. MENT Al. INi/ul01 ATION Twhnic.at S;wnfication in ce!ved Tabl t 3,%.B._.._ _.

Bi it(' f>0 ^ 260. / 81033

  • Late due NRC:.8/1Z81. _..

liete ried Under Technic.il Specific.iti<>n (>.7. 2.b_(2).

Time of occurrence __030_g_.,__ Unit 7_

Date of Occurrence 7/2/81

!dentification and De.,cription of Occurrence:

During routine surveillance tests (SI 4.2.B-7), reactor low pressure permissive switch for recirculation pump discharge valve actuation (2-PS-68-96 switch number 1) failed to operate.

Ceiniition:. l'rior to Oc. urrence Uniti' 1 In rdfueling outage.

~

Unic 2 at 98%.

Unit 3 at 99%.

Action >pecified in tne Tc;hnical Specification Surveillance Requirements met Describe.

' h "' 19_ i OEe r3 _le _.u.lu i imen t.

P b

l None APl'.uwt C. use of occt.crence.

Switch was stuck - reason unknown.

Asudvsis <>f Occurrence.

There was no danger to the health or safrt.y of the public, no release of and no resulting significant activity, no damage to the plant or equipment, chain of events.

(:orr. clive Action: The Barton Model 288 was freed, exercised a number of times d

to verify switch operability, and SI 4.2.B-7 was satisfactorily complete.

This is considered a random failure and no further recurrence control is required.

Failure Data:

BFRO-50-260/78018 l'er~ d - 1.ifetime; ltesponsibility - Document Control Supervisor lier < ntion:

p

+1h vision :