ML20009F889

From kanterella
Jump to navigation Jump to search
Forwards LER 81-062/03L-0
Date released: 01/23/2020 Download: ML20009F889


LER 81-062/03L-0:on 810531,following Reactor trip,turbine- Driven Auxiliary Feedwater Pump Failed to Deliver Full Flow. Caused by Speed Control Setpoint Drift.Trimpot Adjusted. Locking Nut Tightened & Locking Putty Applied
ML20009F891
Person / Time
Site: Sequoyah 
Issue date: 06/26/1981
From: Harding M
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F891 (1)
Forwards LER 81-062/03L-0
ML20009F888
Person / Time
Site: Sequoyah 
Issue date: 06/26/1981
From: Green H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F888 (1)