r-3 g
k[
DUK E PoWElf CO>WMY POWEft UUILDING 522 SOUTil Citt:HCH STPEET. CIIAHLDTTE, N. C. 2H242 3
~~
t
/ ice PmCS Of NT IC.EP'* 3NE' A# f. 7C a July 2, 1981 373-a u 2 s.t.- a mcwoN h
f('* b{=
A t
3 Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission g
r Region II i
JUL 3 01981* '}
101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 S
" S m,i ap Re: McGuire Nuclear Station b,
f Unit 2
/ 64; d Docket No. 50-370
Dear Mr. O'Reilly:
Pursuant to 10CFR 50.55e please find attached Significant Deficiency Report SD 370/81-06.
Very truly yours, s
t'
/
William 0. Parker, Jr.
RWO/php Attachment cc: Director Ms. M. J. Graham Office of Inspection & Enforcement Resident Inspector U. S. Nuclear Regulatory Commission McGuire Nuclear Statioa Washington, D. C. 20555 I
5I l
!!87En7SEh S
~_ - _.
i Report Number 50-370/81-06 Report Date July 2, 1981 Facility McGuire Nuclear Station Unit 2 Icantification o'i ceficiency 3
Radiographic film for reactor vessel CRDM housing welds supplied by Westinghouse does not meet the requirements of ASME Section III Appendix IX.
Initial Report Or June 3,1981, Mr. J. Bryant of NRC Reaion II, Atlanta, GA, was notified of this deficiency by Messers. W. O. Henry, J. E. Cavender, and J. K. Berry of Duke Power Company, Charlotte, NC 28247. This notification was a result of i
potentially reportable items CA-81-19 and MC-81-ll.
30-day Follo.-Up Report
~
Westinghouse determined on June 24,1981 that 13 RT films at Catenba and 11 RT films at McGuire exceeded the film density requirements. These welds will require additional volumetric examination by Westinghouse. This work is expected to start about August 15, 1981, when the Catawba reactor vessel head can be removed. The Catawba resident NRC inspector was present during the film evaluation by Duke and Westinghouse.
)
One film for a CRDM weld was not found in the McGuire records and will also be included in the reexamination.
Westinghouse is continuing their technical. evaluation of the radiograph tech-nique used. Also a CRDM mockup is being made to evaluate different volumetric examination techniques.
A final report will be provided by December 15, 1981.
i l
i i
l l
I
-