ML20009F507

From kanterella
Jump to navigation Jump to search
Forwards LER 81-052/03L-0
Date released: 01/23/2020 Download: ML20009F507


LER 81-052/03L-0:on 810619,nuclear Instrumentation Channel N-35 Observed to Be Reading Low & Erratic W/Unit Recovering from Turbine Trip.Caused by Failure of High Voltage Power Supply.Power Supply Replaced
ML20009F512
Person / Time
Site: North Anna Dominion icon.png
Issue date: 07/13/1981
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F512 (2)
Forwards LER 81-052/03L-0
ML20009F505
Person / Time
Site: North Anna Dominion icon.png
Issue date: 07/13/1981
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F505 (1)