Forwards LER 81-094/03L-0
Date released: 01/23/2020 Download: ML20009F498


LER 81-094/03L-0:on 810603,flow Rate Measurement Instrumentation on Waste Monitor Tank B Declared Inoperable During Attempted Liquid Waste Release.Caused by Root Valves to Tank Flow Transmitter Left Closed After Equipment Mod
ML20009F503
Person / Time
Site: McGuire Duke Energy icon.png
Issue date: 07/02/1981
From: Nardoci P
DUKE POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F503 (1)
Forwards LER 81-094/03L-0
ML20009F497
Person / Time
Site: McGuire Duke Energy icon.png
Issue date: 07/02/1981
From: Parker W
DUKE POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F497 (1)