ML20009F026

From kanterella
Jump to navigation Jump to search
Forwards LER 81-014/03L-0.Detailed Event Analysis Encl
Date released: 01/23/2020 Download: ML20009F026


LER 81-014/03L-0:on 810608,during Testing,Hpci Pump Turbine Tripped on Overspeed Prior to Reaching Rated Sys Flow.Sys Declared Inoperable.Caused by Improper Valve line-up Procedure.Valve Throttled & Tested
ML20009F033
Person / Time
Site: Cooper Entergy icon.png
Issue date: 06/24/1981
From: Flannigan R
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20009F033 (1)
Forwards LER 81-014/03L-0.Detailed Event Analysis Encl
ML20009F025
Person / Time
Site: Cooper Entergy icon.png
Issue date: 06/24/1981
From: Lessor L
NEBRASKA PUBLIC POWER DISTRICT
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20009F025 (2)