TELECO?Y MEESAGE J0-30 h*

TO:

215-337-532s FRCM:

315-342-5523 CATE/ TIME 7/10/81

]340 Telepncne tic cer Telepncne tiumoer TO: BOYCE H. GRIER Frc=:

liiagara Mchawk Power Corporati,on Director of Regulatory Operation fline Mile Point tiuclear Station UStiRC P.egion I Unit il c31 Park Avenue P.O. Box !3E King of Prussia, PA.

19405 Lyccming, tiew York 13093

SUBJECT:

PRCMPT REPORTASLE OCCURRE? ICE CCCKET i.0. EO-2E0 LICE:iSE ti0. DPR-63 ASSIGiED LER ??O.

oi_n

.EVEfiT.DATE:

n oia, REPORT DATE:

7/in/91 EVENT DESCR~P"IO.'l:

While operating at approximately 290 MWE, the shaft driven feedwater pump was started.

Injection of high conductivity water in the dead leg caused a reactor water conductivity and chloride excursion.

Conductivity exc eded 10 (J!H0/01 (15.5 J!H0/CM peak) for less than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and chlorida G

e

~ ppm (1.4 ppm peak) for less than four hours.

4

/

CCMPO:!ENTS ItiVOLVED:

Reactor Vessel -

's g

CAUSE' A?iD REMEDIAL ACTIO :

C 2 IISBN -~~I Event was caused by incomplete flush of feedwater system h 6 DanD '

startup.

Remedial action.was accomplished through normal reactor'wa V lean-up, i,/

s-Jstem operation.

FACILITY STATUS:

% THERMAL E',l 57%

c) Routine Startup g)

Shutdcwn d) Rcutine Shutccwn h)

Refueling e) Steady State Oper i)

Other

^

f) Load Change j) tiot Applicacie I

A written follow-up report will be sent within two weeks.

r t

TELECOPY TO B. Grier FROM Edward Leach DATE 7/10/81 ilAME fiAME 4

8107280207 810710 l

DR ADOCK 05000220

-f PDR Se

._