July 1, 1981
Original document not available
to NRC
-
"e
Docket Nos. 50-460/513
Certifi
4/,MCh
,
t-
s ci4
9
' ,
Washington Public Power Supply System
g@# g
ATTN: Mr. D. W. Mazur
g.
g
Program Director, WNP-l/4
a
N
T
4
!!
3000 George Washington Way
"
k.
C
Richland, WA 99352
7
g
,,,
k,f,%\\\\'jf '
Gentlemen:
/
This refers to the inspection conducted by "- NRC inspection team iifentified
in the enclosure, during the period of April 21-23, 1981 of your activities
being performed relative to the environmental qualification of safety-related
electrical equipment and to the discussions of our findings with Mr. G. C. Sorensen
and other members of your staff at the conclusion of the inspection.
This inspection was part of NRC's program of reviewing environmental qualification
of equipment used in harsh environments of nuclear facilities. The program
is intended to provide assurance that qualification testing of selected equip-
ment is performed in accordance with the criteria and guidelines of NUREG-0588
and IEEE Standard 323-1974 and applicable daughter standards.
The inspections
are intended to assess the adequacy of a particular environmental qualification
test program by reviewing the test plans and associated procedures prior to
test performance so that any comments relative to the test methodology may be
considered in a timely manner. You should not conclude that the NRC's inspections
replace or decrease a licensee's responsibility in determining the acceptability
,
of any specific product or service.
The enclosed copy of our inspection report identifies areas examined during the
inspection including the evaluation of the test plans intended for use in the
qualification of electrical terminations manufactured by the Burndy Corporation
and a solenoi operated valve manufactured by the Target Rock Corporation.
The results of our review of the test plans and discussions with cognizant
personnel indicated that the qualification test program generally conforms to
the guidelines of IEEE 323-1974 and NUREG-0588.
In order to more accurately
describe the test program, the test plans should be revised to document certain
test methods or specimen preparation as discussed in the enclosed inspection
report.
In accordence with Section 2.790 of the Commission's " Rules of Practice," Part
2, Title 10, Code of Federal Regulations, a copy of this letter will be placed
in the Commission's Public Document Room.
If this report contains any infor-
mation that you believe to be proprietary, it is necessary that you make a
written application within ten (10) days to this office to withhold such
i
information from public disclosure. Any such application must include a full
l
statement of the reasons on the basis of which it is claimed that the information
I
is proprietary, and should be prepared so that proprietary information identified
-gGol
s
8107270200 810701
)
PDR ADOCK 05000460
G
_ _ _ _ _ _ _ _ _ - _ _ _ _ .
-
.
.
.
.
,
.
.
_2_
in the application is contained in a separate part of the document.
If we do
not hear from you in this regard within the specified period, the report will
be placed in the Public Document Room.
As discussed with you by our inspectors, this inspection is the first of several
that we are planning with respect to the Burndy and Target Rock environmental
qualification test programs. To enable efficient continuation of our reviews
it is requested that we be informed of the planned inspection test points for
the following activities:
Specimen Preparation: (radiation, thermal, wear aging; baseline and
vibration testing)
Seismic Testing
Accident Radiation Testing
Test Set-Ups
LOCA/MSLB Environmental Testing
In addition to the above information, please provide a response to the inspection
team's comments discussed in the Exit Interview, paragraph E of the enclosed copy
of our inspection report.
Should you have any questions concerning this inspection, we will be pleased to
discuss them with you.
Please forward your response to this office with a copy
to Mr. G. W. Reinmuth, U.S. Nuclear Regulatory Commission, Washington, DC 20555.
Your cooperation in these matters is appreciated.
Sincerely,
Obh
R. H. Engelken, Director
Region V
Office of Inspection
and Enforcement
Enclosure:
Inspection Reports Nos. 50-460/
81-05; 50-513/81-05