ML20009D494

From kanterella
Jump to navigation Jump to search
Forwards LER 81-008/01T-0
Date released: 01/23/2020 Download: ML20009D494


LER 81-008/01T-0:on 810710,four Tubes in Steam Generators Were Verified to Have Degradation Greater than 40% Which Exceeds Plugging Limit of Tech Specs.Caused by Intergranular Attack Due to Caustic.Defective Tubes Plugged
ML20009D497
Person / Time
Site: Point Beach 
Issue date: 07/16/1981
From: Burstein S
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20009D497 (4)
Forwards LER 81-008/01T-0
ML20009D493
Person / Time
Site: Point Beach 
Issue date: 07/16/1981
From: Burstein S
WISCONSIN ELECTRIC POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20009D493 (1)