. _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ - _ _.

w l

I RECEIVING & SilIPPIllG INSTRUCTIONS i

Includes samples of four (4) specific Purchase Requisitions, one of which munt be used for each shipment - whether package is empty or contains a source.

All, but the sample Purchase Requisitions, are taken in whole from Part 2,Section IX, Pages 34-41 of " John Decro Foundry Radio-graphy Manual".

1

)

l 0107210156 810609 PDR ADOCK 07100443 C

PDR June,1981 l

___d

v s

Part 2,Section IX 1X.

TRANSPORTATION OF RADIOACTIVE MATERIAL A.

' Receiving 1.

Radioactive material required by John Deere Foundry will be ordered by Radiation Protection Officer and will be either of following:

(a) 50 Cu Cobalt 60 - Model #428-8 capsule shipped in Tech / Ops source changer Model 488 or 771.

(b) 15 MilliCursource contained in Tech / Ops Model 571 survey meter calibration kit.

2.

When radioactive material has been ordered, the Radiation Protection Officer will notify receiving department by completing form (Exhibit #1 Page :41) and sending form to receiving department.

NOTE:

This form spells out the specific responsi-bilities of the receiving department.

3.

Receiving department must notify Radiation Protection Officer (s) or Radiographer (s) immediately upon receipt of radioactive material, and store in safe area until surveyed and released by Radiation Protection Officer (s) or Radiographer.

NOTE:

A safe place is an area unoccupied by employees within 8' of package.

4.

Radiation Protection Officer or Radiographer will monitor the package cf radioactive material in receiving department.

(a)

Monitoring must be done within 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> of roccipt, or within 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> if received after normal working hours.

(Normal hours - 07:00 to 15:50).

(b)

Radiation Level limits:

(1) 200 Mr/llr,on external surface (2) 10 Mr/llr?at 3' from external surface (c)

If radiation levels do not exceed limits, receiving department will deliver package to exposure roon.

(d)

If radiation levels exceed limits, Radiation Protection Officer must immediately notifv the

" Director of Region III N.R.C." by telop!ine, and telegraph, mallogram or facsimile; and the final delivering carrier; and direct receiving department to deliver package to exposure room immediately.

Proceed per instructions from N.R.C. j

Apart 2,Section IX (Continued) 6 (c)

Results of survey will be entered on receiver, dated and signed by Radiographer or Radiation Protection Officer and a copy of receiver placed in Radiation Protection Officer's files.

B.

Shipping There exists f-ur various shipping categories for John Deere Foundry:

Category No. 1 Shipping a Co 60 source (approximate. activity-a 25 Cu) in either Tech /Op #488 or Tech /Op #771 1

source changer.

Category No. 2 Shipping a Co60 (Activity) approximately 8?Millicu) in a Tecb/Op #571 meter calib ation kit.

1 Category No. 3 Shipping an empty: Tech /Op Model 488 lead shielded container.

Category No. 4 Shipping an empty Tech /Op Model 771 containing depleted uranium.for shielding.i Category No. 1 and No. 2 (Model #488 or #771, or #571 Kit - containing a Cobalt 60 source) 1.

Insure that source is secured in the proper shielded storage position in the shi ping container and that shipping container is properly closed and secured.

2.

Attach-a lead security seal and wire to the shipping container closure and securciseal with a John Deere Identification stamp.

3.

Survey the shipping container at the surface and at three feet from the surface and determine the proper radioactive shipping labels using the criteria of Table II, 1.

(49 CPR 172.403) and partially reproduced below.

SURFACE 3 FEET Does not exceed 0.5 Radioactive - White I None Mr/Mr More than 0.5 Mr/Hr Does not Radioactive - Yellow II and does not exceed Exceed 1.0 50 Mr/Hr Mr/Hr More than 50 Mr/Hr oes and does not exceed Rndioactive - Yellow III e

0 200 Mr/Hr Mr/Hr

__f -

n Part 2,Section IX (Continued) 4.

Properly complete two shipping labels with the following information: (Example: Radioactive - White I, Radioactive-Yellow II or Radioactive - Yellow III).

(a)

Radioisotope' Cobalt 60 (b)

Number of curies as determined by age on the decay chart.

(c)

Transport index, which is the maximum radiation level measured at 3' from surface.

5.

Remove any old shipping labels and apply two properly completed labels to opposite two pides of shipping container.

6.

Mark outside of shipping package with proper shipping name - Radioactive Material, special form, n.o.s.,

NA 9187 if not already marked.

7.

Perform a radioactive contamination wipe test on the surface of shipping package, and:then ow steps 5,6,& 7 in_Part 2,-Section VIII-( age. 3.F) of'radi'o-graphy manual prior _to mailing.6 ggy (a)

Wipe test swab to be mailed immediately to

" Technical Operations": for testing.

(b)

Shipping container is to remain secured in exposure room until test results are received from Tech / Ops.

8.

Upon receipt of leak test results from Tech / Ops proceed as follows:

(a)

If results of wipe test exceed.001 micro curies /

100 Sq. Cm, contact Tech / Ops immediately for instruc-tions - Do Not Shin Package.

(b)

If results of wipe test do not exceed.001 microcuries/

100 Sq. Cm. proceed with7 hipping.

NOTE:

Leak test results will be retained in file.

Although not required by N.R.C.,

should be retained as proof that test was made prior to shipment.

9.

Submit a Purchase Reouisition to purchasing department to cover package to be shipped, must include the following specific information:

(a)

Proper shipping name:

Radioactive Material special

form, n.o.s.,

NA9182 (b)

Name of radionuclide,:

Cobalt-60 (c)

Physical form:

Special form i

~

' Pert 2,Section IX '(Continued)

(d)

Activity of source _. (in curies or millieurio2),

(e)

Category df label: (Example - Yellow II or Yellow III)

(f) ' Transport Index: (Actual measured' radiation in Mr/Hr at 3' from surface).

(g)

Container 2. Transport 3Statust For'the #571 Kit - Dot Specificationl7A?4

~~

For'the #488 source chcnger - DotispecificationT551 For the,L771 source changer - Type;g;USNRC; Certificate l

of' Compliance;No,bOSA/9107/Bi-(h)

Shipper's Certification:

This is to certify that the above named materials are properly classified, descri bed, packaged, marked and labeled and are in-proper condition for~ transport according to the applicable regulations of the Department of Trans-portatic:.

Signed:

Radiation Protection Officer Date:

10.

Deliver prepared package and copy of " Receiving Department Shipping Instructions (Exhibit #2, Page[42.)3to Receiving for shipment.

Category No. 3:

Empty lead shielded container - Model 488 Source Changer.

l.

Insure that the container does not contain a radioactive source.

2.

Insure that package is properly closed including a security seal on the enclosure stamped with "JD" identifications.

3.

Survey the external surface of the package to insure that the radiation levels do not exceed 0.5 Mr/Hr, 4.

Remove _any old shipping labels from package and attach two " Empty" labels to opposite sides of package.

5.

Perform a radioactive contamination wipe test on the surface of, package.

Che_ckN ipe:.withisurveyfmeter prior'_to" mailing.3 (a)

Wipe test swab to be mr.iled immediately tc Tech / Ops for testing.

(b)

Shipping container is to remain secured in exposure room until test rern1'a arn roccived from Tech / Ops.

- Yt -

, Part 2, Ecction -IX '(Continued) 16. -

Upon receipt of leak test results from Tech / Ops proceed

-as follows:

(a)

_If results of wipe test exceed.001 microcuries/100 Sq. Cm., contact Tech / Ops immediately for instruc-

-tions - Do Not Ship Package.

(b)

If results of wipe test do not exceed.001 micrn-curies /100fSqs C Q proceed with shipping..

7.

Submit a Purchase Order Requisition to Purchasing Department stating "This is an Empty Tech / Ops Model 488 shipping container - a Dot 55 Specification Package".

8.

Deliver package"to Receiving Department for shipment.

Category No. 4:

Empty depleted uranium shielded container - Model 771 source changer.

1.

Insure that the container does not contain a radioactive source.

2.

Insure that package is properly closed including a s

security seal on-the enclosure stamped with "JD" identifications.

3.

Perform a radioactive contamination wipe test on the surface of package.

Check; wipe 3withEstrveyjme teryirior[to} mailing D 4

(a)

Wipe test swab to be mailed immediately to Tech / Ops 3

for testing.

(b)

Shipping container #.s to remain secured in exposure room until test results are received from Tech / Ops.

4.

Upon receipt of leak tcst results from Tech / Ops proceed as follows:

(a)

If results of wipe test exceed.001 microcuries/100 Sq. Cm.,

contact Tech / Ops immediately for instruc-tions - Do Not Ship Package.

4 (b)

If results of wipe test do not exceed.001 micro-curies /10078 Q Cm., proceed with shipping.

s 5.

Survey the package at the surface and at 3' from surface to determine the proper radioactive shipping labels to be attached to package.

(a)

If the surface radiation level is less than 0.5 Mr/Hr and no measurable radiation level at three feet from the surface, NO label is required.

Mark the outside of the packag Twith "Radioac.tivelDepice,ifnfo)sW 3

4 Identification Nor^UNL2911'andithe-statement:-

4

" Exempt ^ fromTshecificat' ion packaging, ' marking,:,anh labeling,s.and exempt;from the provisionsfofJ49iCFR 1,73.393 perf 49 ~CFR,173.3917(c).nfExempt fromithe. 3 requirements fof;~ 4 9.CFR sPart. : '

(ajl(6)J"-

175 perq49CFRjl75.10e#

~

-. 3 8 -.

.s Part'2, Section IX-(Chntinued)

(1)

Submit a Purchase Order Requisition to Purchasing Department which must include the following information:

Instructions to Receiving Department:

All information listed below must be on the shipping papers.

Proper shipping name: $adioact1vd$D5ykce) n.o'.s.,cUN2911LM Name of Radionuclide:

Depleted uranium Physical form:

Solid metal Activity:

.15 Millicuries /lb.

"ExempEffrom/ specification, pack'agiiig,' marking,

I and: labeling,;d and.(exempt) from.the 3 provisioris, ~.;h of.. CFRl173 k393 f per 39f CFR: 173.391 f.(c).; LExempt from the?requirementseof;49.4CFR Part 175.:per 49f CFR J175 '.101 (a)m ( 6 ). "Js i

Shipper's Certification:

This is to certify that the above named materials are properly classified, described, packaged, marked and labeled and are in proper condition for transport according to the applicable regulations of the Department of Transportation.

Signed:

Radiation Protection Officer Date:

(b)

If the surface radiation level exceeds 0.5 Mr/Hr, or there is any measurable radiation level at 3 feet from the surface, use the criteria of Table II.1 (49 CPR 172.403) and reproduced on Page 35-of.this Section.

(1)

Submit a Purchase Order Requisition to Purchasing Department which must include the following information:

Proper shipping name:

Radioactive Material,

LSA, n.o.s.,

Un2912 Name of Radionuclide:

Depleted uranium Physical form:

Solid metal

'Part 2,Section IX (Continued)

Activity:

.15 millicuries /lb.

Category of Label Transport index (actual measured radiation at 3' from surface in Mr/Hr)

USNRC Identification Number:

USNRC USA /9107/B Deliver prepared package and copy of " Receiving Department Shipping Instructions (Exhibit #2, Page '41); to Receiving for shipment.

'3-PocJe 2,' Section' IX. (Continued)

. EXHIBIT #1 r

A i

i RECEIVING DEPARittEtiT INSTRUCT 10'45 FOR TifE RECEIVINC AND HANDLING OF FACKAGES CONTAINING RADI0 ACTIVE MATERIAL The following radioactive material has been ordered 4

and should be delivered on _

(Er.t. date of delivery).

1.

Receiv.ing Department must notify one of the following immediately upon receipt of above material:

John Hartman, Radiation Protection Officer Ext. 2-6788 or 944-4315 Larry Sandoval, Radiographer Ext. 2-6764 or 755-0442 Cnuck Winfree, Radiation Protection Officer Ext. 2-5894 or 799-3877 Jim Power, Radiographer Ext. 2-6764 or 496-2440 2.

Package should be placed in an area which is not occupied within 8' of package.

3.

Receiving Department notes on receiver date and time and name of s'uova person notified.

4.

One of the four (4) persons listed in item one (1) must survey the package j

within 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> of receipt, or within 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> if received after 15:50. The results, time and date of survey will be noted on the receiver, and signed by the Radiographer or RaJiation Protection Of ficer conducting the survey.

l 5.

Receiving Department provides copy of receiver to person (s) making radiaticn i

survey of package.

i 6.

Receiving Department will deliver package to exposi.re room immediately upon 4

release by Radiation Protection Of ficer or Radiographer.

3 A COPY OF TilESE INSTRUCTIONS TO DE POSTED IN RECEIVING DEPARTMENT -

in addition, Receiving Department will receive a copy of this instruction sheet prior to receipt of package containing RADIOACTIVE MATERIAL.

J0tlN HARitL\\N RADIATION PROTECTION OFFICER 4/22/81 i

i 1

er c% k.N

__m.41-9

'Paga 2,Section IX (Continued)

EXHIBIT #2 RECEIVING DEPARTMENT INSTRUCTIONS FOR TIIE SHIPPING OF PACKAGES CONTAINING RADIOACTIVE MATERIAL 1.

Upon receipt of " Exterior Shipping Order" notify one of the following i

from Radiography to make arrangements for delivery of package to l

receiving:

l l

John Hartman, Radiation Protection Of ficer - 1st shif t l

Ext. 2-6's :

Larry Sandoval, Radiographer Ext. 2-6764 Chuck Winfree, Radiation Protection officer - 2nd shift Ext. 2-589.i Jim Power. Radiographer Ext. 2-6764 2.

Prepare necessary shipping papers.

IMPORTANT: All specific information noted on E.S.O. milst be included on shipping papers - and signature of a " Radiation Protection Officer" must be included.

3.

Store the pekage in an area unoccupied within 8' cf package until loaded on rarrier's truck.

NOTE: This package is completely safe for Receiving Department to handle with a forklift.

4.

Provide a copy of shipping papers to Radiography for filing.

PLEASE POST g RECEIVING DEPARTMENT - in addition you will be sent a copy of these instructions prior to shipping.

J0liN HARTMAN RADIATION PROTECTION OFFICER 4/22/81

Part 2,Section VIII, (Continued) 2.

Remove source tube from face of shield or remove shipping plug.

3.

Wet the swab with EDTA solution.

Shake off excess and insert the swab into the hole in the shield.

Wipe the interior of the hole thoroughly by rotating swab holder.

4.

Withdraw swab and place in plastic envelope.

5.

The swab should now be monitored by turning the survey meter to its most sensitive range.

Place the meter in a low background area and move the swab in its plastic envelope to the meter, not the meter to the Suab.

6.

If there is no indication on the meter, or if the indication is no more than 0.2 Mr per hour above l

background, put the plastic envelope with the swab in the mailing box and mail to Technical Operations, Incorporated, Burlington, Massachusetts.

Be sure to fill out and return the identification sheet.

7.

If the swab should show more than 0.2 Mr por hour, do not mail.

Contact Technical Operations, Inc.,

for specific instructions.

NOTE:

If the survey meter available does not have the capability of detecting as little as 0.2 Mr per hour, ship the wipe-test swab to Technical Operations, Inc.,

via express.

Do not ship if the radiation from the swab exceede 2 Mr per hour and cc,ntact Technical Operations, Inc., for specific instructions.

The wipe-test swab will be subjected to a precise radio assay when received by Technical Operations, and a leak-test certificate will be mailed promptly.

r i

l RECEIVING & SIIIPPING INSTRUCTIONS Includes samples of four (4) specific Purchase Requisitions, one of which must be used for each shipment - whether 1

package is empty or contains a source.

l All, but the sample Purchase Requisitions, are taken in whole from Part 2,Section IX, j

Pages 34-41 of " John Deere Foundry Radio-graphy Manual".

June,1981

y 3-Part'2,JSection IX

~

IX.

TRANSPORTATION OF RADIOACTIVE ' MATERIAL E

LA.

Receiving 1.

. Radioactive' material required by John neere' Foundry will be or.dered by Radiation Protection' Officer'and-L will Le either of following:

l (a)

_50 Cu Cobalt 60 - Model #428-8 capsule shipped in Tech / Ops source changer.Model-488 or 771.

i 15 MilliCU~lsource contained in Tech / Ops Model (b) _ 571 survey meter calibration kit.

2.

When radioactive material has been orderod, the

-Radiation. Protection Officer will notify receiving

~

department by completing form -(Exhibit #1 Page {i)2f and' sending form to receiving department.

NOTE:

This form spells out the specific responsi-bilities of the receiving' department.

3.

~ Receiving department must notify Radiation _ Protection Officer (s) or Radiographer (s)- immediately upon receipt of'. radioactive material, and store in safe area until surveyed and released'by Radiation Protection Officer (s) or Radiographer.

NOTE:

A safe place is an area unoccupied by employees within 8' of package.

Radiation Protection Officer or Radiographer will monitor-4.

the package of radioactive material in receiving department.

(a)

Monitoring must be done within 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> of receipt, or within 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> if received after normal working hours.

(Normal hours - 07:00 to 15:50).

(b)

Radiation Level limits:

(1) 200 Mr/Hrion external surface (2) 10 Mr[Hrlat 3' from external surface (c)

If radiation levels do not, exceed limits, receiving department will deliver package to exposure room.

(d)

If radiation levels exceed limits, Radiation Protection Officer must immediately notify the

" Director of Region III N.R.C." by telephone, and telegraph, mailogram or facsimile; and the final delivering carrier; and direct receiving department to deliver package to exposure room immediately.

Proceed per instructions from N.R.C.

~34-

.- f** ' Part 2, Sc0 tion li(Continued)2

~ C

. (ei Results ofEsurvey.will be entered on receiver,.datedi and' signed by Radiographer or Radiation Protection Officer.and a copy of receiver placed in Radiation

Protection Officer's files.

l B.

Shipping There exists four.various shipping categories for' John Deere Foundry:

Category No. 1. Shipping a'Co 60 source (a M biliat Ma5EN ity-

~

l

251Cu) in'either Tech /Op #488 or, Tech /Op #771 source changer.

Category No. 2 Shipping,a Co60 (ActiMit'y*- approximitely b 85Millicu) in a Tech /Op-#571 meter calibration kit.

Category No.13. Shipping en, empty 3 Tech /Op Model 488 lead-shielded container.

Category No. 4 Shipping an emptyyTech/Op Model 771.chntal'ning dypleted uranium: forf ah_ieldirig;}

3 Category No. 1 and No. 2 (Model #488 or #771, or #571 Kit - containing a Cobalt 60 source) 1.

Insure that source is secured in the proper shielded storage, position in the shipping container and that shipping container is properly closed and secured.

2.

AttachUailead security seal and wire to the shipping container closure and riecure'Iscal with a John Deere Identification stamp.

3.

Survey the shipping container at the surface and at three feet from the surface and determine the proper radicactive shipping:

'{

labels using the criteria of Table II, 1.

'l (49 CFR 172.403) and partially reproduced below.

~

SURFACE 3 FEET Radioactive - White I Does not exceed 0.5 None More than 0.5 Mr/Hr Radioactive - Yellow II and does-not exceed Does not 50 Mr/Hr Exceed 1.0 Mr/Hr More than 50 Mr/Hr Does not Radioactive - Yellow III nd docts not exceed exceed 10 Mr/Hr

.Part 2,Section IX (Continued) 4.

Properly complete two shipping labels with the following information: (Example: Radioactive - White I, Radioactive-Yellow II or Radioactive - Yellow III).

(a)

Radioisotope. Cobalt 60 (b)

Number of curies as determined by age on the decay chart.

(c)

Transport index, which is the maximum radiation level measured at 3' from surface.

5.

Remove any old shipping labels and apply two properly completed labels to opposite two: sides of shipping container.

6.

Mark outside of shipping package with proper shipping name - Radioactive Material, special form, n.o.s.,

NA~9182,if not already marked.

7.

Perform a radioactive contamination wipe test.on_the surface of shipping package, and;then followLsteps 5,~6',

&L7.in Part'2',Section VIII. (page: 32).of radio.i graphy manu'a1. prior.to. mailing.

yp.gj p

(a)

Wipe test swab to be mailed immediately to

" Technical operations": for testing.

(b)

Shipping container is to remain secured in exposure room until test results are received from Tech / Ops.

8.

Upon receipt of leak test results from Tech / Ops proceed as follows:

(a)

If results of wipe test exceed.001 micro curies /

100 Sq. Cm, contact Tech / Ops immediately for instruc-tions - Do Not Ship Package.

(b)

If results of wipe test do not exceed.001 microcuries/

100 Sq. Cm. proceed with shipping.

NOTE:

Leak test results will be retained in file.

Although not required by N.R.C.,

should be retained as proof that test was made prior to shipment.

9.

Submit a Purchase Reauisition to purchasing department to cover package to be shipped, must include the following specific information:

(a)

Proper shipping name:

Radioactive Material special

form, n.o.s., NA9182' (b)

Name of radionuclide:

Cobalt-60 (c)

Physical form:

Special form

~

i

" Part 2,/Section IX (Continued)

-(d)'

Activity ~of source (in curies or gillicurie,s)3 p (e)

Category of label: (Example --Yellow II or Yellow III)

(f)

Transport Index: (Actual measured. radiation in Mr/Hr at 3' from surface).

(g)

CoriEainEUTFaE[Or~t?SEElud For the # 571 Kit - Dot [Specificatii6n"{7At:

~

Por the #488 source changer - Dottspecifi_cationiS57 For the #771 source changer - Typ ~e5BLUSNRCICertificahA

~"'

"~~

ofgCompliance1NogUSA/91'07/B Q (h)

Shipper's Certification:

.This is to certify that the above named materials are properly classified, described, packaged, marked and labeled and are in proper condition for transport according to the applicable regulations of the Department of Trans-portation.

Signed:

Radiation Protection Officer Date:

10.

Deliver prepared package and copy of " Receiving Department Shipping Instructions (Exhibit #2, Page f4 2.)) to Receiving for shipment.

~

Category No. 3:

Empty lead shielded container - Model 488 Source-Changer.

I 1.

Insure that the container does not contain a radioactive source.

2.

Insure that package is properly closed including a security seal on the enclosure stamped with "JD" identifications.

1 3.

Survey the external surface of the package to insure that the radiation levels do not exceed 0.5 Mr/Hr.

1 4.

Remove any old shipping labels from package and attach two " Empty" labels to opposite sides of package.

J

.1 l

5.

Perform a radioactive contamination wipe test on the surface of package.

j Check (wipelwith Esurvey; meter. priortto1 mailing.;

i (a)

Wipe test swab to be mailec immediately to Tech / Ops for testing.

(b)

Shipping container is to remain secured ib exposure room until test results are received from Tech / Ops. -.-

~

._,\\

  • .'Part42,'Section IX (Continued) 6.

LUpon receipt-of-leak test results from Tech / Ops proceed as follows:

(a)

If results of-wipe test exceed.001 microcaries/100 Sq. Cm.,

contact Tech / Ops'immediately for'instruc-tions - Do Not Ship Package.

(b)

If results of wipe test do not exceed.001 micro-curies /100fSq yCm,5 proceed with shipping.

7.~

Submit a Purchase' Order Requisition to Purchasing Department stating "This is an Empty Tech / Ops Model 488 shipping container - a Dot 55 Specification' Package".

8.

Deliver package to Receiving Department for shipment.

~

-Category No. 4:

Empty depleted uranium shielded container - Model 771 source changer.

1.

Insure that the container does not contain-a radioactive source.

2.

Insure that package is properly closed including a security seal on the-enclosure stamped with "JD" identifications.

3.

Perform a radioactive contamination wipe test on the surface of package.

Checkywipe--with survey l meter { prior?to'nialling.*

l

.m (a)

Wipe test swab to be mailed immediately to Tech / Ops i

for testing.

(b)

Shipping container is to remain secured in exposure room until test results are received from Tech / Ops.

4.

Upon receipt of Aeak test results from Tech / Ops proceed as follows:

(a)

If results of wipo test exceed.001 microcuries/100 Sq. Cm.,

contact Tech / Ops immediately for instruc-tions - Do Not Ship Package.

(b)

If results of wipe test do not exceed.001 micro-curies /100lSq2fCm., proceed with ship}ing.

5.

Survey the package at the surface and at 3' from surface to determine the proper radioactive shipping labels to be attached to package.

(a)

If the surface radiation level is less than 0.5 Mr/Hr and no measurable radiation level at three feet from the surface, NO label is required.

Mark the outside of the packag Twith "RadioactivejDevice[,~Ln;o.'s.,,

Identification 2No; UN!2911'and the-statementi. ";

" Exempt)fromLspecification_ pa'ckaging,; marking,; ands labeling,.;and:exempttfromJthe'provisionsToft49 CFR)

~

173. 393 c per;49 ; CFR '173. 3911(c).; Exempt ^fromfthe.s

. requirements? of;49 CFR: Partu17.5;per 49CFR;175;.-10..; 4 (a)h ( 6 ).,"4

-3@-

F s:

LSection Ix (Continuea).

..ra e 2, (1)~

' Submit a Purchase Order Requisition to Purchasing Department which must include the-following information:

Instructions to Receivir 7 Department:

All information listed below must be on the shipping papers.

1 Proper shipping name:

RadioactiveID5kihe) n '.'o 7 s.,; U.N. 2 9 1 1 J x_..,.

Name of Radionuclide:

Depleted uranium Physical form:

Solid metal-Activity:

.15 Millicuries /lb.

" Exempt?from~[spesiifidat'idE1 packaging { marking,

of"CFR1173.393Fper?.49;CFR?l730391$ provisions' 1, an'dOlab'eling', d and exempt i fsomithe x

~

(c). ; j Exempt I from the 9equirements1of49J CFR1Part;1751per;3 4 9) CFR/175 '.10N(a). ( 6).i" Shipper's Certification:

This is to certify that the above named materials are properly classified, described, i

pacxaged, marked and labeled and are in proper condition for transport according to the applicable regulations of the Department.of Transportation.

Signed:

Radiation Protection Officer Date:

(b)

If the surface radiation level exceeds 0.5 Mr/lir, or there is any measurable radiation level at 3 feet from the surface, use the criteria of Table II.1 (49 CFR 172.403) and reproduced on Page 35 of this Section.

(1)

Submit-a Purchase Order Requisition to Purchasing Department which must include the following information:

Proper shipping name:

Radioactive Material,

LSA, n.o.s.,

Un2912 Name of Radionuclide:

Depleted uranium l

Physical form:

Solid metal

Part 2,Section IX (Continued)

Activity:

.15 millicuries /lb.

Category of Label _

Transport index (actual measured radiation at 3' from surface in Mr/llr)

USNRC Identification Nuribar:

USNRC USA /9107/B Deliver prepared package and copy of " Receiving Department Shipping Instructions (Exhibit #2, Page 41)'i'to Receiving for shipment.

l -.

V l'

j r. Pago 2,.Section IX '.(Contintled)

+

H r

b EXIIIBIT #1 i

l.

RECEIVING DEPAR".HENT f

INSTRUCTIONS FOR TIiE RECEIVING AND HANDLINO OF PACKACES CONTAINING RAD 10ACTIVF. itATERIA1.

The following radioactive tasterial han heen ordered f

and should be delivered on (Est. date of delivery).

1.

Receiving Department must notify one of the following immediately upon receipt of above materialt John Hartm.in, Radiation f.atection Officer Ext. 2-6788 or 944-4315 Larry Sandoval, Radiographer Ext. 2-6764 or 755-0442 Chuck Winfree, dadiation Protection O Micer 2xt. 2-5894 or 799-3877

  • ,1m Power, Radiographer Ext. 2-6764 or 496-2440 2.

Package should be placed in an area which is not occupied within 8' of package.

3.

Receiving Departme ;t notes on receiver date and time and name of abcve person notifled.

4.

One of the four (4) persons listed in item one (1) must survey the package within 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> of receipt, or within 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> if received after 15:50. The reautt a, time and date of survey will be noted on the receiver, and signed by the Radiographer or Radiation Protection Officer conducting the survey.

5.

Receiving Department provides copy of receiver to person (s) making radiation survey of package.

6.

Receiving Departm?nt will deliver package to exposure room immediately upon release by Radiation Protection Ofitccr or Radiographer.

A COPY OF THESE INSTRt:CTIONS TO DE POSTED IN RECEIVING DEPARTMENT -

l in addition, Receiving Department will receive a copy of this

.j instruction shoot prior to receipt of package containing RADlorCTIVE MATERIA!..

JOHN ltARTMAN RADIATION PROTECTION OFFICER l

l 4/22/M v-

.-Y

"*Paga 2,Section IX (Continued) s EXHIBIT #2 RECEIVING DEPARTFJ.NT INSTRUCTICNS FOR Tile SHIPPING OF

{

PACKAGES CONTAINING LAbl0 ACTIVE MATERIAL 1

1.

L'pon recelot of " Exterior Shipping Order" notify one of the following from Radiography to make arrangem nts for delivery of package to receiving:

John Hartman, Radiation Protection Officer - 1st shift Ext. 2-6783 Larry Sandoval, Radiographer Ext. 2-676; Chuck Winfree, Radiation Protection Officer - 2nd shift Evt. 2-5894 Jim Power, Radiographer Ext. 2-6764 2.

Prepare necessary shipping papers.

IMPORTANT: All specific information n>ted on E.S.O. must be included on shipping papers - and signature of a " Radiation Protection Officer" must be included.

3.

Store *he package in an area unoccupied within 8' cf package until loaded on carrier's truck.

NOTE: This package is completely s?fe for Receiving Department to handle with a forkitft.

4.

Proviste a copy of shipping papera to Radiography for filing.

PI. EASE POST IN RECEIVING DEPARTMENT - in addition you will be sent a copy of these instructions prior to shipping.

J0llN RAkTMAN RADIATION PROTECTION OFFICER 4/22/81

-42.

~

Part 2, S ction VIII, (Continued) 2.

Remove source tube from face of shield or remove shipping plug.

3.

Wet the swab with EDTA solution.

Shake off excess and insert the swab into the hole in the shield.

Wipe the interior of the hole thoroughly by rotating swab holder.

4.

Withdraw swab and place in plastic envelope.

5.

The swab should now be monitored by turning the survey meter to its most sensitive range.

Place the meter in a low background area and move the swab in its plastic envelope to the meter, not the meter to the swab.

t 6.

If there is no indication on the meter, or if the indication is no more than 0.2 Mr por hour above background, put the plastic envelope with the swab in the mailing box and mail to Technical Operations, Incorporated, Burlington, Massachusetts.

Be sure to fill out and return the identification sheet.

7.

If the swab should show more than 0.2 F.r per hour, d2 not mail.

Contact Technical Operations, Inc.,

for specific instructions, j

l NOTE:

If the survey meter available does not have the capability of detecting as little as 0.2 Mr per hour, ship the wipe-test swab to Technical operations, Inc.,

via c): press.

Do not ship if the radiation from the swab exceeds 2 Mr per hour and contact Technical Operations, Inc., for specific instructions.

The wipe-test swab will be subjected to a precise radio assay when received by Technical Operations, and a leak-test certificate will be mailed promptly.