VERMONT YANKEE NUCLEAR POWER STATION MONTilLY STATISTICAL REPORT 81-06 FOR TIIE MONit! 0F JUNE, 1981 I
1 8107200335 810710 PDR ADOCK 05000271 R
OPERATING DATA REPORT DOCKET No. 50-271 DATE 81070R COMPLETED BY F.3.
Bu-e py TELEPHONE (802)257-;711 Ext. 137 OPERATING STATUS Notes L. Unit Name:
Vermont Yankee
- 2. Raporting Period:
June
- 3. Licensed Thermal Pcwer(HWt):
1593
- 4. Namnplace Rating (Gross MWe):
540 5.' Dasign Electrical Rating (Net MWe): 514(oc) 504(cc)
- 5. Maximum Dependable Capacity (Gross MRe):
535
- 7. Maximum Dependable Capacity (Net MRe):
504
- 3. If Changes occur in Capacity Ratings (Ictn.a Number 3 Through 7)Since Last Report, Give Reasons'
- 9. Power Level to Which Restricted,If Any(Net MWe):
- 3. Reasons For Restrictions, If Any:
This Month Yr-to-Date Cumulative
- 1. Hours In Reportire Period 720.00
_ 3 343.00
- 2. Number Of Hours Reactor Was Critical 720.00 4,310.12 61.845.90
- 3. Reactor Reserve Shutdown Hours 0.00 0.00 0.00 __
- 4. Hours Generator On-Line 720.00 4.252.05-59.8s1.61
- 5. Unit Reserve Shutdown Hours 0.00 0.00, 0.00
~
- 6. Gross Thcrmal Energy Generated (MWH) 1,141,936.50 6,533,764.00 85.137.281.00
- 7. Gross Electrical Energy Generated (MWH) 372,926.00 2.194.666.00 28.307.511.00 1
- 3. Net Electrical Energy Generated (MWH) 350.488.00 2.094.144.00 9A 911 o99 nn 3
Unit Service Factor 100.0G 37.91 77.81
- 0. Unit Availability Factor 100.00 97.91 77.81
- 1. Unic Capacity Factor (Using MDC Net) 96.,59 95.68 69.24
- 2. Unit Capacity Factor (Using DER Net) 94.71 93.82 67.89 7
- 3. Unit Forced Outage Rate 0.00 2.09 6.96
- 4. Shutdowns Scheduled Over Next 6 Months (lype, Date, and Duration of Each):
Refueling outage scheduled to start October 17. 1981 nnd r en H niin e seven weeks.
m-
- 5. If Shut Doun At End Of Report Period, Estimated Date of Startup:
- 5. Units In Test Status (Prior to Coc=ercial Operation):
Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMB'ERCIAL OPERATION
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-271 UNIT Vermont Yankee DATE 810708 COMPLETED BY F.J. Burger TELEPHONE (802)257-7711 Ext. 137 MONTH June DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1.
492 17.
484 2.
492 18.
488 3.
491 19.
485 i
4 486 20.
486 5.
- f. 88 21 477 6.
479 22.
484 7.-
490 23.
487 8.
492 24.
490 9.
488 25.
485 lo.
469 26.
488 11.
489
- 21. _,
491 12.
490 25.
482 13.
489 29.
489 i
i 14.
479 30.
488 15.
485 31.
16, 479 INSTRUCTIONS:
i On this format, list the average d. lily unit power level in M a-Net for each day in the reporting month.
Compute to the nearest whole :2gawatt.
l t
. _ _ ~. _ _ ~..__...._
.m N
N 3,,
.C..%.
2
.O to M no
' C' M on C. C C
O.
Z O
O p
O Y.
.a f*
O o
n I
i N
I i
=0mme6=>M Typed ~
1 1 1 i i i i i m CC>CcM=m2 F "o:
C. "l: c c Q.O
- o aeam-= c Duration on-ne==-=
c 9 2 3 D W G Fe-(Hours) 2 r* pm nU W@ S a W cc o f* -= c m
m o e n o = :a a 2
x=n mn: r Reason 50
-: u u Hm n
Wwen am M
_c
-D
>= 3 M 3
M H
-M<
-O C -
M O
m mW Methed of C
0 v n" o z n M
c c
HA
.N em Shuttin8 H
2 3
n m
Down Reactor 2
>c n,=,
C m
m z
x t-e k
d C
-m e
W n
m a
e u
t-6 C
o Mm-c c
a w
a e<n u
m v
m v
- ee o
M o=a m
n n in M
M C
M g
E_
T O
3 System Code' o
=
m 2
0" euu o
I i i I O.
C>==
Cc=ponent
"., C "
Code 5 c.
o
.s, M S 9 m(J >=* Pa*
A f*
m - ca A nC
'O M
>== Ch 2 0
2 n3 C
-M mi 2 E D N 5 E=
- =
2g m ""
m
~..
5 H
- i 7:
= M M
COO 2H
=
.m ll=.-i = 2 M M.M C LA A
7 O
M
- a i
M
^MMMM C
C M
Z<
O M
< > U2
- r Cc 4 (n Oc 3
=*
C m r* N :ll-mo c O
C M: 9
==
= rt O4 C
M i
C*
mnM m C*
n->
N*
N B
M O
M -
C C
0 N
m M CA C rt M=
O Uql t2CC 3 N
W CC O
O c
rt
~7 C 3 O O &
- 1 NN
@C O M l C O
- 1 l M N
i wnnU m
o NO W
vM 'O e -
M o
N *1 3
CA
- 2 C
f*
W F
D
^% C ;n a
.=
s Wj C
Ei
"" O 3 P n
j 0
m MM M
m Q
M M
C c M
Cn w t* m n i
N C
M E
9O O===
k M
P*-
- Q C H
-3
& =
W Q
C Cn D go N
~
C e
6
DOCKET NO.
50-271 UNIT Vermont Yanke2 DATE 810708 COMPLETED BY F.J. Burger TELEP110NI (802)257-7711 Ext. 137
]
SAFETY RELATED MAINTENANCE NATURE OF LER OR OUTAGE MALFUNCTION EQUIPMENi' MAINTENANCE NUMBER CAUSE RESI'LT CORRECTIVE ACTION Containment Spray Manual Corrective N/A Worn Parts Spurious Alarms Keplaced Switch Contac Override Key Lock Switch MR 81-638 Blocks For The "BD" RilR Loop i
N/A(1) lireake r s'o t The "B"
RllR Corrective Wern Parts
' Breaker Would Service Water Pump MR 81-6+2 Not Stay Closed Replaced Worn Bushings "B" RBCCW lleat Exchanger Corrective N/A Unknown Tube Leakage Flugged Tubes MR 81-655 Temperature Indicator Corrective N/A Instrument Drift Out Of Cal-T1-VC 4A MR 81-663 lbration Replaced Indicator "A" RBCCW Heat Exchanger Corrective N/A Unknown Tube Leakage Plugged Tubes MR 81-687 RCIC Valve V13-18 Corrective N/A Torque Switch Valve Would Rtzet Torque Switch MR 81-699 Out Of Adjust-Open Only When ment control Switch Was lleld In The Oren Position RCIC Trip / Throttle Valve Preventative N/A Dirt /Corrcsion Slow Actuation Disassembled, Cleaned, MR 81-704
~
and Replaced Parts As Necessary
r
~'
~
~
~~
~
DOCKET No.
50-271 UNIT Vermont Tr.nkee DATE 810708
"#E #
COMPLETED BY TELEP110NE (802)257-7711 Ext. 137 SAFETY RELATED MAINTENAFCE NATURE OF MALFUNCTION LER OR OUTAGE EQUIPMENT MAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION RWCU lleat Exchanger E-15-1A Corrective LER Unknown Vent Line Re-Replaced Parts As MR 81-722 81-16/3L ducer Cracked Necessary And Leaking
= - -
Service Water Pump P7--1A Corrective N/A Normal Wear Packing Gland Adjusted Packing Gland MR 81-737 Leakage U)This MR documents the bre.tker repair. MR 8) -640 documented t lie installation of t be spare breaker uhen this breaker failed to close (LER 81-1 5/3L) and was reported in the May St fitistical Report.
d
=.. _ _
-. --=-
DOCKET NO.
50-271 UNIT Vermont Yankee l
DATE 810708 COMPLETED BY F.J. Burster TELEPHONE (802)257-7711 Ext. 137 REPORT MONTH June I
SUh%iRY 0F OPERATING EXPERIENCES Highlfthts Vermont Yankee operated at 99.56% of rated thermal power for the month.
I Gross electrical generation was 372,926 MW, or 95.91%of design electrical j
capacity.
~
?
Operating Summarv j
The following is a chronological description of plant operations including t
. other pertinent items of interest for the mouth:
1 3
6/1/81 At the beginning of the reporting period the plant was operating at 99.7% of rated thermal power.
l 6/30/81 At the and of the reportir.g period the plant was operating at 99.8% of rated thermal power.