ML20009C022

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for June 1981
ML20009C022
Person / Time
Site: Brunswick  
Issue date: 07/08/1981
From:
CAROLINA POWER & LIGHT CO.
To:
Shared Package
ML20009C020 List:
References
NUDOCS 8107200182
Download: ML20009C022 (18)


Text

, _ _..

.y

- - - - - - - - - ~='

e h

23T(D Ow

D o

>N DOCKET NO. 050 n174 N

UNIT SilUTDOWNS AND POWER REDUt'TIONS UNIT NAME Br"n wi c te ?

n" DATE in1v 1091 l

l COMPLETED BY "r 'n c m H'rri en l

o REPORT MONTil June TELEPl!ONE (919) 657-9521

'N or oo.

ON

'Dra c

l. UNCD
U A c

E Cause & Corrective y*3 E

.! ?

3 4.::' y Licensec

, r, Aetien to c-EU Event u T'

[U No.

Date c-

~1 E LT 0 yO Pr: vent Recurrence

, Report.*-

j@

C-1 f

Reactor coolant in recirc loop A was F

37.5 B

1 N/A CD VALVEX 81017 810,610 greater than 50*F cooler than recirc loop B due to loop.A discharge valve

/

being shut.

Shutdown reactor and equalize reactor coolant temperature throughout coolant boundary.

l 1

r r

(

(

1 i

4 3

E>hibit G Instructions i

2 Methud:

for Preparation of Data l

F: Forced Reason:

1 -M an ual Entry Sheets f.>r Li ensee S: Seheduled A 1 qmpment fadure (Explain) 2 Manual Serain.

Esen Report (LER) File (NUREC.

l 11.Mainteiunee of Test 3 Automatic Scram.

l 0161)

C Refuehog 4 Continuations D Regulator) Restriction E Oper, tor Training & License Examination 5-Load Reductions 3

i F Administrative 6-Other Exhibit 1. Same Source C Operational Error (Explain)

N/77)

Il Other (Explain)

k

- - - - = -

.. - = - _ _ - - - -

w-b b

b 050-0324 DOCKET NO.

UNIT SliUTDOWNS AND POWER REDUCTIONS UNIT N ANTE Brunsvnck 2 DATE Julv 1981 COh!PLETED BY Fran_ces Harrison REPORT 5f 0NT11_ June TELEPHONE (919)457-9571

... "i E

.5 g

'h 3,.:" il Licensee

, v, "ge, Cause & Corrective E

?

e-1 Action tu n?

3V Prevent Recurrence No.

Date g

3g i

jyJ Event v

l-jE jE 5

, Report #

v d

.e 81018 810622 F

129.9 A

3 NA CB GENERA The 2A MG tachometer generator was pulled and. inspected revealing excessive carbon deposits within the casing causing a high resistive short from the brush holder insulator and ground.

Remove tne 2A'MG tachometer generator and cleaned the-carbon. deposits. Also cleaned the commutotor and checked for<

~

grounds.

4 3

Exhibit G -Instructions 2

hiethod:

1 Reason:

1 51an ual for Preparation of Data F: Forced S: Scheduled A 1 quminent faihire (Explain) 2 hfanual Scrarn.

Entr> Sheets for Liecusce Esent R: pert (LER) File (NUREG.

n Maintenance of Test 3 Auturnatic Scram.

C Itefushng 4-Cont.inuations 0161'r D Itegut.itors Itestriction E. Operator Training & License Examination 5-Load Reductions 3

F Administrative 6-Other Exhibit 1. Same Source C-Operational Error (Expla.n)

(9/77) li Other (Explain) 1

APPENDIX DOCKET NO:

050-0325 UNIT:

Brunswick No. 1 DATE:

June 1981 COMPLETED BY:

Frances Harrison OPERATIONS

SUMMARY

BRUNSWICK UNIT NO. 1 Brunswick Unit No. I was off the line for the entire month of June for a planned maintenance outage.

There are 476 BWa and 160 PWR spent fuel bundles in the Brunswick Unit No. 1 fuel pool.

l l

.- ~ ~.

APPENDIX i

DOCKET NO: 050-0324 UNIT:

Brunswick No. 2 DATE: July 1981 l

COMPLETED BY: Frances Harrisoa 1

a OPERATIONS

SUMMARY

BRUNSWICK UNIT NO. 2

/-

- Brunswick Unit No. 2 operated at a 52.4% availability factor for the month of June with 34.1% capacity factor. There were two "off-line" outages this month, both are detailed in Appendix D, the unit shutdowns and power reductions log.

l There are 264.BWR and 144 PWR spent fuel bundles in the Brunswick Unit No. 2 fuel

{

pool.

I 1

L I

i I

l

[

\\

t i

I i

i 4

i l

l-

I g.-

APPEND 1X B AVERAGE LAILY POWER LEVEL DOCKET NO.'050-0325 UNIT BRUNSWICK UNIT 1 DATE 06/29/81 l

COMPLETED BY FRANCES HARRIS 0M TELEPHONE 919-457-9521 MAY 81 DAY.

AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL (MWE-NET)

(MWE-NET) 1

-5.

17

-4.

2

-4.

18

-5.

3

-4.

19

-4.

~

4

-5.

20

-5.

5

-4.

21

-5.

6

-5.

22

-5.

7

-5.

23

-5.

8

-5.

24

-4.

9

-4.

25

-5.

10

-5.

26

-4.

11

-4.

27

-5.

12

-4.

28

-5.

13

-4.

29

-4.

i 14

-5.

30

-5.

15

-5.

31

-5.

i 16

-5.

s S

1.16 - 8 i

. -, =,..

.e-

~

~

N OPERATING DATA REPORT DOCKET NO. 050-0325 DATE 06/29/81 COMPLETED BY FRANCES HARRISON TELEPHONE 9.19-457-9521 GPERATING STATUS

1. UNIT NAME: BRUNSWICK UNIT 1 I NOTES I
2. REPORTING PERIOD: MAY 81 I

I

3. LICENSED THERMAL POWER (MWT): 2436 I

I 4

NAMEPLATE RATING (GROSS MWE): 867.0 I

I

5. DESIGN ELECTRICAL RATING (NET MWE): 821.0 I

I

6. MAX DEPENDABLE CAPACITY (GROSS MWE): 815.0 :I I
7. MAX DEPENDABLE CAPACITY (NET NWE): 790.0 6.

IF CHANGES OCCUR IN CAPACITY RATINGS (I EMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:

9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE): NONE
10. REASONS FOR RESTRICTION IF ANY:

THIS YR TO CUMUL MONTH DATE ATIVE

11. HOURS IN REPORTING PERIOD 744.0 3623.0 36864.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 0.0 2134.3 25936.4
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1647.1
14. HOURS GENERATOR ON LINE 0.0 2056.8 24438.7
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 0.0 3841375.6 49965308.5
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 0.0 1256185.0 16581779.0
18. NET ELECTRICIAL ENERGY GENERATED (MWH)

-3384.0 1203366.0 15950800.0

19. UNIT SERVICE FACTOR 0.0 56.8 66.3
20. UNIT AVAILABILITY FACTOR 0.0 56.8 66.3
21. UNIT CAPACITY FACTOR (USING MDC NET)

-0.6 42.0 54.8

22. UNIT CAPACITY FACTOR (USING DER NET)

-0.6 40.5 52.7 f.3. UNIT FORCED OUTAGE RATE 0.0 8.3 17.4

24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP:

6/20/81

26. UNITS IN TEST STATUS (PRIOR TO COMMERICIAL OPERATION): FORCAST ACHEIVED INITIAL CRITICALITY INITIAL ELECTRICITY CONMERICIAL OPERATION 1.16 - 9

APPENDIX B AVERAGE DAILY POWER LEVEL DOCKET NO. 959-9324 UNIT B90NSWICK UNIT 2 DATE 07/96/El COMPLETED BY FRANCES HARRISON TELE HONE 919-457-9521 JUNE 81 DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL (HWE-NET)

(MWE-NET) 1

-10.

17

730, 2

-7.

18 736.

3

-9.

19 736.

4

-9.

20 735.

5

-10.

21 643.

6

-9.

22 607.

7

-12.

23

-13, 8

36.

24

-12.

9 54.

25

-12.

10 15.

26

-11, 11

-12.

27

-12.

12 320.

28 195.

13 471.

29 4R3.

14 619.

30 669.

15 629.

16 613.

1.16 - 8

OPE;ATING DATA REPORT

~

DOC W:; T NO. !i59-0325 pnTE 47/06/81 (0:tPLETED DY FRANCEB HAR.;ISON TE lPHONE 919-457-9521 OPERATING STATUS

1. UNIT NLME: BRUNSWICK UNIT 1 I NOTES I
2. REPCRTING FERIOD: JUNE 81 I

I

3. LICEMiED THERMAL COWER (MW7): 2436 I

I 4

NacEFLLTE RATING (GROSS MWE): 567.0 I

I

5. DESIGN ELECTRICAL RATING (NET >WE): 821.0 I

.I

6. MAX EEFENDABLE CCPACITY (GRCis MWE): 215.0 I I
7. MAX-DEFENDABLE CA;ACITY (NET M E): 790.0 8.

IF CHANGES OCCUR.IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:

9 POWEP LEVEL TO WHICH RESTRICTED IF ANY (NET MWE): NONE

10. REASONS FOR RESTRICTION IF AN):
THIS YR TO CUMUL MONTH DATE ATIVE
11. HOURS IN REPORTING PERIOD 720.0 4343.0 37584.0
12. NUMEER OF HOURS REACTOR WAS CRITICAL 0.0 2134.3 25936.4
13. REACTOR RESERVE SHUTDOWN HOURS 6.0 0.0 1647.1
14. HOURS GENEPATOR ON LINE 0.0 2056.8 24438.7
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 0.0 3841575.6 49965308.5
17. GR055 ELECTRICAL ENERGY GENERATED (MWH) 0.0 1256155.0 16581779.0
18. NET ELECTRICIAL ENERGY GENERATED (MWH)

-4017.0 1199349.0 1594678?,0

19. UNIT SERVICE FACTOR 0.0 47.4 65.0
20. UNIT AVAILABILITY FACTOR 0.0 47.4 65.0
21. UNIT CAPACITY FACTOR (USING MDC NET)

-0./

s5.0 53.7

22. UNIT CAPACITY FACTOR (USING DER-NET)

-0.7 33.6' 51,7

23. UNIT FORCED OUTAGE RATE 0.0 6.3 17.4
24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPEr DATER AND DURATION OF EACH):
25. IF HUTDOWN AT END OF REFORT FERIOD, ESTIMATED DATE Oc ETART UP:

7,* 8/81

26. UNITS IN TEST STATUS (PRIOR TO COMMERICIAL OPERATION): FORCAST ACHEIVED INITIAL CRITICALITY INITTAL ELECTRICITY COMMERICIAL OPERATION 1.16 - 9 a

r e

v-T--

-w

= - - - - -*

yr

-- *-"'=-

4 4

i wrPENDfX B AVERAGE DAILY POWER LEVEL DOCKET NO. 050-0325 UNIT BRUNSW.ICK UNIT 1 D4TE 07/06/81 COMPLETED'BY FRANCES HARRISON TELEPHONE 919-457-9521

. JUNE 81 DAY AVG.-DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL (MWE-NET)

-G1WE-NET) 1

-5.

17

-5.

2

-5.

18

-4.

m 3

-6.

19-

-5.

4

-6.

20

-5, 5'

-6.

21

-5.

6

-6.

22

-5.

7

-5.

23

-5.

8

-5.

24

-6.

4 i

9

-5.

25

-5.

i 10

-5.

26

-7.

}

-11

-5.

27

-8.

j 12

-5.

28

-7.

13

-5.

29

,8.

14

-5.

30

-LO.

15

-5.

16

-5.

1 l

1.16 - 8 l

1.-,..

~

OPEFATING DATA REPORT DOCKET NO. 050-0324 DATE 07/06/81 COMPLETED BY FRANCEO HARRISON TELEPHONE 919-457-9521 OPERATING STATUS

1. UNIT NAME: BRUNSWICK UNIT 2 I NOTES I
2. REPORTING PERIOD: JUNE 81 I

I.

3. LICEN5ED THERMAL POWER (MWT): 2436 I

I

4. NAME? LATE RATING (GROSS MWE): 867.0 I

I

5. DESIGN ELECTRICAL RATING (NET MWE): 821.0 I

I

6. MAX DEPENDABLE CAPACITY (GROSS.MWE): 815.0 I I
7. MAX DEFENDABLE CAPACITY (NET MWE): 790.0
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE): NONE
10. REASONS FO'R RESTRICTION IF ANY:

1

THIS YR TO CUMUL MONTH DATE ATIVE
11. HOURS IN REPORTING PERIOD 720.0 4343.0 49608.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 415.1 2219.1 31241.4
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
14. HOURS GENERATOR ON LINE 377.5 2003.6 28967.8 1".

UNIT' RESERVE SHUTDOWN HOURS 0.0 0.0 0.0

16. GROSS THERMAL ENERGY GENERATED (MWH) 620516.6 3257801.1 52869181.9
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 205234.0 1106974.0 17671420.0
18. NET ELECTRICIAL ENERGY GENERATED (MWH) 194041.0 1046268.0 16951697.0
19. UNIT SERVICE FACTOR 52.4 46.1 58.4
20. UNIT AVAILABILITY FACTOR 52.4 46.1 58.4 21.. UNIT CAPACITY FACTOR (USING MDC NET) 34.1 30.5 43.3
22. UNIT CAPACITY FACTOR (USING DER NET) 32.8 29.3 41.6

'23. UNI FORCED OUTAGE RATE 47.6 51.8 17.8

24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):

I l

I

25. IF SHUTDOWN AT END OF. REPORT PERIOD, ESTIMATED DATE OF START UP:

0/ O/ 0 l

26. UNITS IN TEST STATUS (PRIOR TO COMMERICIAL OPERATION): FORCAST ACHEIVED INITIAL CRITICALITY INITIAL ELECTRICITY COMMERICIAL OPERATION 1.16 - 9 i

I e

!~

APPENDIX DOCKET NO:

050-0325 UNIT:

Brunswick No. 1 DATE:

June 1981 COMPLETED BY:

Frances Harrison OPERATIONS,

SUMMARY

BRUNSWICK UNIT NO.

l.-

Brunswick Unit No. I was off the line for the entire month of June for a planned maintenance outage.

There are 476 BWR and 160 PWR spent fuel bundles in the Brunswick Unit No. 1 fuel pool.

i e

e 0

,,,,,.--,e.,-... - -.,.,,

. - - -,.. -. - ~

v.

- ~

- - - ~ ~ ~

=

- - + -

APPENDIX DOCKET NO:

050-0324 UNIT:

Brunswick No. 2 DATF.:

July 1981 COMPL2TED BY:

Frances Harrison OPERATIONS:

SUMMARY

BRUNSWICK UNIT NO. 2' Brunswick Unit No. 2 operated at a 52.4% availability factor for the month of June with 34.1% capacity factor. There were two "off-line" outages this month, both are detailed in Appendix D, the unit shutdowns and power reductions log.

There are 264 BWR and 144 PWR spent fuel bundles in the Brunswick Unit No. 2 fuel pool.

4 6

1 8

..-,.-nn.

w