ML20009B571

From kanterella
Jump to navigation Jump to search
Forwards LER 81-036/01T-0
Date released: 01/23/2020 Download: ML20009B571


LER 81-036/01T-0:on 810602,CRD P-10 Inserted Slowly, Exceeding Limits for One Four Control Rod Array.Caused by Sticking Scram Solenoid Valve S02-0305-118.CRD Rebuilt & Returned to Svc
ML20009B576
Person / Time
Site: Dresden 
Issue date: 06/12/1981
From: Holland P
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20009B576 (3)
Forwards LER 81-036/01T-0
ML20009B570
Person / Time
Site: Dresden 
Issue date: 06/09/1981
From: Scott D
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20009B570 (1)