ML20009B042
| ML20009B042 | |
| Person / Time | |
|---|---|
| Issue date: | 06/29/1981 |
| From: | Book H NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Manly P GAMMA INDUSTRIES, INC. |
| Shared Package | |
| ML20009B043 | List: |
| References | |
| NUDOCS 8107140698 | |
| Download: ML20009B042 (1) | |
Text
[en at:Q h
UNITED STATES 8"
'n NUCLEAR REGULATORY COMMISSION 3
,E REGION V k
1990 N. CALIFORNIA BOULEVARD SulTE 202, WALNUT CREEK PLAZA e,,,e WALNUT CREEK, CALIFORNIA 94596 June 29, 1981 License No. 53-16847-01 Gamma Corporation
[8\\
649 Californ.a Avenue 4
g*I Suite 102 C
Wahiawa, Hawaii 96786 7
6,-
JUL13G81M3 Attention: Mr. Phillip J. Manly u mu, w-unsa mm.c =
Gentlemen:
7
Subject:
NRC Inspection Qc3 This refers to the routine safety inspection conducted by Mr. Grayson of th's office on May 7,1981, of activities authorized by NRC License No.
% -16847-01, and to the discussion of our findings held by Mr. Grayson with you at the conclusion of the inspection.
The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Commission's rules and regulations and the conditions of your license.
The inspection consisted of selective examinations of procedures and representative records, interviews with personnel and observations by the inspector.
During this inspection, it was found that certain of your activities appeared to be in noncompliance with NRC requirements.
The items and references to the pertinent requirements are listed in. Appendix A.
These items have been categorized into severity levels'as described in the Federal Register Notice (45 FR 66754) dated October 7,1980.
Your response to this notice is to be submitted in accordance with the provisions of 10 CFR 2.201 as stated in Appendix A, Notice of Violation.
l If you have any questions on this matter or concerning this inspection, please telephone Mr. Grayson on 415-943-3700.
Sinc,erely, GE l
H. E. Book, Chief l
Radiological Safety Branch l
A.
[k 8107140698 810629 NMS LIC30 53-16847-01 PDR f