... _ _ _. -

$ SACRAMENTO MUNICIPAL UTILITY DISTRICT O 6 SMUD 95813; (916) 452 3211 May 5, 1981 t-ldW)R O

MAY'1119814e

  • DIRECTOR OF NUCLEAR REACTOR REG' LATION

~~.A U 8== =c**ma 4 J

ATTENTION: JOHN F STOLZ CHIEF G

3 OPERATING REACTORS BRANCH 4

/,\\

Q U S NUCLEAR REGULATORY COMMISSION 4/

- s/

N W/;SHINGTON DC 20555 DOCKET 50-312 RANCHO SECO NUCLEAR GENERATING STATION UNIT N0 1 On Ma-ch 12, 1981, the Babcock & Wilcox Company submitted B&W's Generic Report BAW-1511 P, "A Radiation-Induced Reduction and Charpy Upper-Shelf Energy of Reactor Vessel Welds", to the NRC by, letter from

, James H. Taylor to A nn S. Berggren. This report was submitted by B&W on behalf of the Reactor Vessel Materials Subcommittee of the B&W Owners' Group. The Sacramento Municipal Utility District is a member of this subcommittee.

We have leviewed this report and find the data presented therein appli-cable to Rancho Seco, Unit No. 1.

This report shows that the Rancho Seco, Unit No.1 Reactor Vessel welds are predicted to exhibit a Charpy Upper-Shelf Energy c.' more than 50 f t-lb for more than 16 years. Completion of work in other phases of the B&W Owners' Group Program will provide justi-fication for plant operation for the 40-year design life of the vessel.

b John J Mattimoe Assistant General Manager and Chief Engineer

/

8105120 M

[

AN ELECTRIC SYSTE M S E RVIN G MORE THAN 600.000 IN THE HEART OF C A LIF 0 R N I A

.