ML20008F480

From kanterella
Jump to navigation Jump to search
Forwards Suppl 5 to IE Bulletin 80-17, Failure of Control Rods to Insert During Scram at BWR, to Inform of Actions No Longer Required
ML20008F480
Person / Time
Site: Hatch, Browns Ferry, Grand Gulf, Brunswick, Hartsville, Phipps Bend  
Issue date: 02/13/1981
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Jackie Jones, John Miller, Parris H, Stampley N
CAROLINA POWER & LIGHT CO., GEORGIA POWER CO., MISSISSIPPI POWER & LIGHT CO., TENNESSEE VALLEY AUTHORITY
References
NUDOCS 8104210061
Download: ML20008F480 (3)


Text

-

pra 4%q'o UNITED STATES

!],g ~ g NUCLEAR REGULATORY COMMISSION

.giy"I !-

,_s REGION ll o1.M Q.~

101 MARIETTA ST.. N.W., SUITE 3100

' * %./

ATLANTA, G EcRGIA 30303 j

Gentlemen:

The enclosed II Bulletin No. 80-17, Supplement 5, is forwarded to inform you of actions that are noelonger required. A written response to this supplement is not required.

If you desire additional information regarding this matter, please contact this nE! ice.

~~ -:- ~

Sincerely, J

( %%=

1 James P. O'Reilly Director

~

~'

Enclosures:

1.

II Bulletin 80-17 Supplement 5 2.

List of Recently Issued II Bulletins

?I

,g i

D '.

l

\\

Rw(PIf15k Ich <9 9

8 RPR031981m %

  • * =.

==.. c.,

4 b,'tri 9 jj\\ \\\\,'t 810421 004(

9

e

/pa recoq'b, UNITED STATES

$c}4."

~

3,g i

NUCLEAR REGULATORY COMMISSION

.: c REGION 11

%, 'C_[j'f o, 5,$!b 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303

  • ...=

,s

  • Gentlemen:

Inclosed is IE Bullet'in No. 80-17, Supplement 5 which is transmitted for informa-tion with regard to your nuclear power facility.

Should you have any questions regarding this bulletin supplement, please contact, this office.

-:~

Sincerely, k'N James P. O'Reilly Director

Enclosures:

1.

IE Bulletin No. 80-17, Supplement 5 2.

List of Recently Issued IE Bulletins I

l I

IE Bulletin No. 80-17, Supplement 5 (ACTION)

~

Fe'oruary 13, 1981 Addresses In Reference To 1.

Carolina Power and Light Company 50-325 Brunswick Unit 1 Attn:

J. A. Jones 50-324 Brunswick Unit 2 Senior Executive Vice President and Chief Operating Officer 411 Fayetteville Street

~.

Raleigh, NC 27602 i

2.

Georgia Power Company 50-321 Hatch Unit 1 Atta:

J. H. Miller, Jr.

50-366 Hatch Unit 2 Executive Vice President

/

270 Peachtree Street Atlanta, GA 30203 3.

Tennessee Valley Authority 50-259 Browns Ferry Unit-1 Atta:

H. G. Parris 50-260 Browns Ferry Unit 2 Manager o,f Power 50-296 Brcwns Ferry Unit 3 500A Chestnut Street Tower II Chattanooga, T[ 37401

~... -

e t

m

.a.

O 1

l.

I 8

- -. - ~ -. --

O IE Bulletin No. 80-17, Supple:nent 5 (INFORMATION)

February 13, 1981 Addresses In Reference To 1.

Mississippi Power.ind Light Company 50-416 Grand Gulf Unit 1 Atta:

N. L. Sta:spie7 50-417 Grand Gulf Unit 2 Vice President of Production P. O. Box 1640 Jackson, MS 33205 2.

Tennessee Valley Authority 50-513 Hartsville Unit 1 Atta:

H. G. Parris 50-519 Hartsville Unit 2 Manager of Power 50-520 Hartsville Unit 3 500A Chestnut Street Tcwer II 50-521 Hartsville Unit 4

  • ./

Chattanooga, TN 37401 50-553 Phipps Send Unit 1 50-554 Phipps Send Unit 2 F

M

,.g O

SSINS No.: 6820 Accession No.:

301104259 IEB 80-17, Supp. 5 UNITED STATES NUCLEAR REGULATCRY CCS.ISSION WASHINGTON, D.C.

20555 February 13, 1981 IE BULLETIN NO. 80-17, SUPPLEMENT 5: FAILURE OF CONTROL RCDS TO INSERT DURING A SCRAli AT A BWR Description of Circumstances:

On July 3,1980, the NRC issued II Bulletin No. 80-17, that required actions to be taken by licensees of all operating GE BWRs. Among the actions required, Item 6(a) required a prompt notification report by telephone to the appropriate,

Regional Office followed by a telecopy or other written submittal. These reports were required in the event that any of the systems (HPCI, RCIC, SLCS, RPT, RER/pcol cooling, and main steam bypass) were found to be less than fully operable.

These reports have served the purpose of notifying NRC of cases of potential reduction in operability of systems important to the mitigation of consequences of an anticipated transient without scram (ATWS) event. These reports are no longer necessary since improvements have been accomplished to increase the reliability of control rod scram

- Actions No Longer Necessary ov-Licensees:

Further reporting is not required in response to Item 6(a) of IE Bulletin No. 80-17.

This does not change the reporting requirements set forth in your license technical specifications.

No written response to IE Bulletin 80-17, Supplement 5, is required.

IE you have any questions regarding this matter,. please contact the appropriate NRC Regional Office.

Attachment:

Recently issued IE Bulletins l

l

\\

e Attt.chmznt IEB 80-17, Supp. 5 February 13, 1981 RECENTLY ISSUED IE BULLETINS Bulletin No.

Subject Date Issued Issued To 81-01 Surveillance of 1/27/81 All power reactor Mechanical Snubbers facilities with an OL

& to specified facilities with CP 30-2S Operating Problems with 12/19/30 All B'aR facilities Target Rock Safety-Relief with an OL & specified Valves at BWRs near ter:n OL B'aR facilities & all B'aRs with a CP Supplement a Failure of Control Rods 12/18/80 To specified BWRs to 80-17 to Insert During a Scram with an OL & All at a BWR BWRs with a CP 80-24 Prevention of Damage 11/21/80 All power reactor Due to Water Leakage facilities with an Inside Containment OL or CP (Ocfober 17, 1980 Indian Point 2 Event)

~~

i 80-23 Failures of So1ehbid 11/14/30 All power reactor ---

Valves Manufactured by facilities with Valcor Engineering OL or CP Corporation 80-22 Automation Industries, 9/11/80 All radiography Model 200-520-008 Etaled-licensees Source Connectors i

80-21 Valve yokes supplied by 11/6/80 All light water Malcolm Foundry Company, Inc.

reactor facilities with OLs or cps Supplement 3 Environmental Qualification 10/24/80 All power reactor to 79-01B of Class 1E Equipment facilities with an OL Supplement 2 Environmental Qualification 9/30/80 All power reactor to 79-013 of Class 1E Equipment facilities with at OL OL = Operating License CP = Construction Permit e

., - - - -