Approves 801219 Request to Use Later Code Edition & Addenda in re-analysis Program for ASME Section 3,Class 1 Chemical & Vol Control Sys Pump Seal Injection Line & Pressurizer Relief Lines
ML20008F160
Person / Time
Site: Summer 
Issue date: 03/05/1981
From: Tedesco R
Office of Nuclear Reactor Regulation
To: Nichols T
SOUTH CAROLINA ELECTRIC & GAS CO.
References
NUDOCS 8103120416
Download: ML20008F160 (2)


Text

m wg (fr d"gureg

-[ h,, ,'g o

UNITED STATES NUCLEAR REGULATORY COMMISSION p g WASHINGTON. D. C. 20555 gv j Docket No. 50-395 h

Mr. T. C. Nichols, Jr.

A l' ]gO 4

Vice President & Group Executive

' a_

S Q

-Nuclear Operations

_ u,4g@,jgg/ A g South Carol!na Electric & Gas Company c,

=

g

=~

P. O. Box 764

/

/

Columbia, South Carolina 29218

4. Y.

Dear Mr. Nichols:

SUBJECT:

USE OF L

' CODE EDITION AND ADDENDA IN THE REANALYSIS PROGRAM FOR THE VIRGIL C. SUMMER NUCLEAR STATION In your letter of December 19, 1980 you requested authorization to use~a later Code edition and addenda than that previously committed to ia che FSAR for the purpose of annlyzing the ASME Section III, Class 1, CVCS pump seal injection line ani the ASME Section III, Class 1, pressu:izer relief lines.

i As you noted in your lette;, the 1971 edition of Section III of the Code does not provide alternate design rules for small bore piping. This relaxation of the design rules was provided for in the Sumer 1975 Addenda to the 1974 edition of the Code and was expanded further in the Sumer 1976 Addenda and applies to 1 inch nominal pipe size and smaller piping. These Code modifications permit 1 inch and smaller piping to be designed in accordance with the class 2 rules of the code and is applicable to the CVCS pump seal injection line.

Similarly, the Surm:er 1979 Addenda to the 1977 Edition of the Code provides a revised treatment for the stresses resulting from linear radial thermal gradient and is applicable to the pressurizer relief lines. Other aspects 'of the analysis of the pressurizer relief lines will also be performed in accordance with Article NB-3000 of the 1977 Edition through the Sumer 1979 Addenda to the Code.

We find the selective use of the Code editions and addenda proposed by the applicant to be acceptable since their use supplement the earlier Code editions and is consistent with the intent of the Code.

Sincerely, W

Robert L. Tedesco Assistant Director for Licensing Division of Licensing cc: See next page 6

N 81081204jf

.u.

Mr. T. C. Michols, Jr.

Vice President & Group Executive Nuclear Operations South Carolina Electric & Gas Company Af4g g g ISST P. C. Box 764 Columbia, South Carolina 29218 cc: Mr. William A. Williams, Jr.

Vice President South Carolina Public Service Authority 223 North Live Oak Drive Moncks Corner, South Carolina 29461 J. B. Knotts, Jr., Esq.

Debevoise & Liberman 1200 17tn Street, N. W.

Washington, D. C.

20036 Mr. Mark 8. Whitaker, Jr.

Group Manager - Nuclear Engineering & Licensing South Carolina Electric & Gas Company P. O. Box 764 Columbia, South Carolina 29218 Mr. Brett Allen Bursey s

Route 1, Box 93C Little Mountain, South Carolina 29076 s

Resident Inspector / Summer NPS c/o U. S. NRC-Route 1, Box 64

..J.e.nkins.vi.lle, South Caroli.na.

29065...._

.. g..

e t

1:.

p s.

A.

. s..

~.,-.

a vy -

c-

.g

. : c.. g..,..:.4

.:.3.

w.,

.r.

-J

  • l

>. 5,'

9

,E e

.4

i'.

.f'dA

J.

h e

'd

.