05000271/LER-1981-007-03, /03L-0:on 810205,Torus-RB Vacuum Breaker Differential Pressure Indicating Switch 16-19-324,model 288, Actuated Above Tech Spec Limit.Caused by Setpoint Drift. Switch Exercised,Reset & Returned to Svc

From kanterella
(Redirected from ML20008E742)
Jump to navigation Jump to search
/03L-0:on 810205,Torus-RB Vacuum Breaker Differential Pressure Indicating Switch 16-19-324,model 288, Actuated Above Tech Spec Limit.Caused by Setpoint Drift. Switch Exercised,Reset & Returned to Svc
ML20008E742
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 03/04/1981
From: Murphy W
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20008E738 List:
References
LER-81-007-03L, LER-81-7-3L, NUDOCS 8103090553
Download: ML20008E742 (1)


LER-1981-007, /03L-0:on 810205,Torus-RB Vacuum Breaker Differential Pressure Indicating Switch 16-19-324,model 288, Actuated Above Tech Spec Limit.Caused by Setpoint Drift. Switch Exercised,Reset & Returned to Svc
Event date:
Report date:
2711981007R03 - NRC Website

text

F U. S. NUCLEAD RESULATCOY COMMISSION NRC FORM 364 G.77)

LICENSEE EVENT REPORT LER 81-07/3L CONTnOLsLOCx:l l

l l

1 l

l@

(PLEasE PRINT 02 TYPE ALL REQUl%ED INFOIMATION) i 6

f5Til lv i T 1 v l Y I S I 11@l 0101 -101 O! 010101 -l 01 Ol@l4 I t 11 l111 l@l I

l@

i 4 3 LICENSEE CCOE 14 15 UCENSE NLMBER 25 26 LICENSE TYPE a0 57 6 M ta CON'T

%,"c' l L @l 015 l 01010 l 2l 71 1 @l0 l2 10 151811 @l 0 l 310 l 4 l 8 l 1l@

lotil I

e 60 61 QQCKET NUMSER 6d 69 EVENT DATE I4 75 REPORT DATE 80 EVENT DESCRIPTION ANO PROBA8LE CONSEQUENCES O'o Iol2l l During surveillance testing, Torus-RB Vacuum Breaker AP switch DPIS 16-19-32A act-l io,3, l uated at 0.504 psid and was above the T. S. 3.7. A.5.a limit of < 0.5 psid. The l

10 l A ; l switch was immediately reset.

Redundant switch DPIS 16-19-32B tested within limits l lois1 1 and was available. Based on the above, there were no odverse consequences to the l

l 0 l6 ] l public health and unfety.

There were no previous reportable occurrences of this l

1017 I I type.

I 10144 1 s0 7

e, E

CQ E SUSC E COMPONENT CODE SUSCODE S

E l0l9l lIlBl@

@ l Z l@ lI l N l S l T l R l Ul@ l S j@ l Z l@

7 6

9 to 11 12 IJ 18 19 20 SE QU ENTI AL CCCURRENCE REPORT REVIS#0N g g,nO EVENTVEAR R EPORT NO.

CODE TvPE NO.

@y(E, l 8l 1l l-l l0l0l7l y

l0l3l lL l

(---j l0 l a

,, 21 22 23 24 26 27 28 29 30 31 32 AhCN QNP NT ME HOURS S8 :

POR 8.

SUPPL MANUPAC RER AK N l El@l Zl@

l Z l@

l Z l@

l0l0l010l lNl@

lYl@

lAl@

lB l0 l8 l0 l@

JJ 34 35 36 37 40 41 42 43 44 47 CAUSE DESCRIPTIO% AND CORRECTIVE ACTIONS l i l o l l The event was due to setpoint drif t on the Barton Model 288 Dif ferential Pressure l

I i i i i l Indicating Switch.

The switch was exercised. reset, and returned to service.

I l i 121 l I

lil ! l I

W l I

7 8 3 80 SA $

%*OWER QTHERSTATUS 013 Av OISCOVERv 0ESCRIPTION I1 15 l lE l@ l 110l Ol@l NA l

lBl@l Surveillance Test l

s a,criviTv ColTENT 7

AMOUNT oF ACTivify @ l toCATioN oF RELEASE @

Rett ASEO or aELEAsE NA l

NA l

l1 l6 l d h d@l PERSONNEL ExPoSOES NUM8ER TVPE

DESCRIPTION

l1 17ll0l0l0l@lZl@l NA l

PERSCNNEL N;u'ItES DESCRIPTION @

NUveER li la l l 0l 0l 0l@l NA l

7 3 3 11 12 80 LOSS OF OR OA. MAGE T0 SACILiTv Q TYPE

DESCRIPTION

%./

NA l

l1 l 9 l 1 Zl@l 7

4 ?

10 80 [f

SSUE

DESCRIPTION

12601 bl NA l

ll ll tlll l1ll a "

" 2 810309055J anen P. Wrphy (802) 257-7711 i

PHONE:

NAME OF P9EPARER