i TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 374o1 400 Chestnut Street Tower II

~

March 2, 1981 e@dl D

Mr. James P. O'Reilly, Director 97 "I'lR O G ;gg -)jl Office of Inspection and Enforcement 84 U.S. Nuclear Regulatory Commission Region II - Suite 3100

, i/

101 Marietta Street k

/C" Atlanta, Georgia 30303 g

7 tn

Dear Mr. O'Reilly:

PHIPPS BEND NUCLEAR PLANT UNIT 1 - REPORTABLE DEFICIENCY - EMBEDDED PLATES WITHOUT HEAT TRACEABILITY (NCR PBNP-156)

Initial notification of the subject deficiency was made to NRC-0IE 3egion II, Inspector R. W. Wright on October 14, 1980. The final report on the deficiency was submitted on January 13, 1981. As requested by Region II Inspector B. R. Crowley in Inspection Report Nos. 50-553/81-01 and 50-554/81-01 transmitted to TVA in C. E.

Murphy's February 11, 1981, letter, we are enclosing the supplemental to the final report.

If you have any questions, please l

call Jim Domer at FTS 857-2014 l

Very truly yours, TENNESSEE VALLEY AUTHORITY I

N ll; g

L. M. Mills, Manag e Nuclear Regulation and Safety Enclosure cc:

Mr. Victor Stello, Director (Enclosure) i Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 i

_~

bod i

S v\\

810809056l o u 0; 3,;em.

I 5

=.

= _. -

. ~.

A 4

i ENCLOSURE PHIPPS BEND NUCLEAR PLANT UNIT 1

~

EMBEDDED PLATES WITHOUT HEAT TRACEABILITY NCR NO. PBNP-156 10 CFR PARTS 50.55(e)

SUPPLEMENTAL TO FINAL REPORT' 1

i Cause The nature of the deficiency is such that an exact determination of

{

its cause is not possible. The deficiency was probably due to human error in the recording of heat numbers as the materials were logged

[

}

in.

?

l Action to Prevent Recurrence

}

I t

The appropriate personnel have been reinstructed in the need for j

proper and accurate documentation of material heat numbers as i

specified in Receiving Inspection Storage and Preventative I

Maintenance Procedure C-501 and in addition, Quality Control i

Information Prc:edure, QCI-C-301.Il has been revised (as underlined) j i

to read:

Prior to unloading the material, verify that the heat number on t.he (**VA Requisition Form) 575 is acceptable for use per the latest list of acceotable heat numbers.

f I

This revision should prevent any material from entering the j

warehouse which is not on Phipps Bend's lists of acceptable material j

heat numbers (heat number log). Therefore, regardless of the cause

[

of an improper log entry (be it human error or otherwise), the error

}

would be detected by implementation of this procedure.

a 1

i; l.

?

4 f

J r

I f

i 1

1 i

i k

i

\\

i t

h l

-- -=

. - _