VIRGINIA ELECTRIC AND l' OWE N CO M I% NY H rcuxon1>,VratorazA 2026a March 4, 1981 t

Mr. Harold R. Denton, Director Serial No. 149 Office of Nuclear Reactor Regulation N0/DCW:jmj Attn:

Mr. Robert A. Clark, Chief Docket No. 50-L8 Operating Reactors Branch No. 3 License No, MPF-4 7

Division of Licensing U.S. Nuclear Regulation Commission i

Washington, D.C.

20555 Gentlemen:

SURVEILLANCE OF RCS FLOW SPLITTER PLATES NORTH ANNA POWER STATION UNIT NO. 1 As requested by Mr. L. B. Engle, of your staff on Friday, February 27, 1981, we are forwarding this letter of intent.

In accordance with North Anna Unit 1 Technical Specification 4.4.10.1 we have completed ultrasonic testing on all Unit 1 flow splitter plates. This testing revealed a number of indications in loop 'A' flow splitter plate.

In light of these results we intend to perform additional ultrasonic testing of the Unit 1 flow splitter plates during a maintenance outage tentatively scheduled for November, 1981.

I We also intend to continue the augmented loosse parts monitoring program.

t Should you have any further questions feel free to contact our staff.

Very truly yours, B.R[ Sylvia l