ML20008E351

From kanterella
Jump to navigation Jump to search
Testimony at NRC Public Hearings Re Draft Programmatic EIS for Decontamination of Tmi.Nrc Safety Stds for Tritium Based on Outdated Dosage Calculations That Grossly Underestimate Toxicity to Human Life
ML20008E351
Person / Time
Site: Crane Constellation icon.png
Issue date: 10/06/1980
From: Stillman I
AFFILIATION NOT ASSIGNED
To:
Shared Package
ML20008E337 List:
References
RTR-NUREG-0683, RTR-NUREG-683 NUDOCS 8010240620
Download: ML20008E351 (6)


Text

_-. _ _ - _ - _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

l n*

,4.

Testimony Before NRC Public H aring2 R2garding the f_ I r' ' ' '

Drcft Programmatic Environmsntsl Irpect Statement for Decontsmination of TMI Nucleer Station, Unit 2 Both the NRC and Metropolitan Edison admit that they are unable to remove tritium from the hundreds of thousand of gallons of contaminated water resulting from the infamous accident that occurred at Three Mile Island, one and a half years ago. Accor.fing to their draf t EIS, this tritiated water will ultimately end up in the Susquehanna River and be carried downstream into Chesapeake Bay.The plan is to release about 3,500 Ci of tritium over 3 period of a few months. Now the average annual release of tritium from a nuclear power plant is only 400-500 Ci, whi.ch means that on a similar annual basis TMI will be releasing about twenty times more tritium than it would under normal operating conditions. We are told not to be concerned because the critiated water will be sufficiently diluted with non-tritiated river water so that the actual concentration of tritium shall f all within the NRC safety standards. This assurance does not assuage my concern for at least two very good reasons; namely, it is the cumulative amount of tritium rather than its concentration

~

that is the significant statistic in this case - never before have the people near a nuclear plant been subjected to three and a half thousand curies

[of tritium in their fishing and drinking water and, secondly, the NitC safety standards for tritium are based on outdated population dosage calculations that grossly underestimate the radiotoxicity of tritium to human life.

The remaining part of my testimony is meant to amplify the two reasons given above in a slightly more scientific vernacular that should be comprehensible totheNRCCommidionersandtothepublicingeneral.IftheNRCisinterested in a more detailed scientific presentetion, including documentation of the y

appropriate research, that is now in the publication process and can be 9

forwarded at some future date.

80 1024elasto z

' '.,,?

  • _1_

Inhomogenious Dispersion Versus Uniform Dilution Conventional engineering wisdom asserts that dissolved tritium or tritiated water rapidly diffuses thr'ughout any body of water, reaches o

its equilibrium concentration, and r' mains uniformly distributed in that e

body of water forever.

This rather simplistic view does not take sev~eral additional factors into consideration such as convection

currents, d

thermal differences and different rates and strength of physical afsorption.

For example, if a nuclear power plant (e.

g.,

Three-Mile Island) discharges its tritiated water into a naturally flowing river ( e. g. Susquehanna River) then that tritium does not instantaneously diffuse throughout the total volume of river. water to achieve maximum dilution; but rather, it may very well stay within certain currents or be adsorbed by the sediment of the river bed (or its aquatic contents) or even remain within the cooler regions of the, river wherethermal diffusion is less vigorous, all of these additional factors would prevent a rapid equilibration of the discarded tritrium'within the river thereby resulting in an uneven distribution of the tritium.

In other words, parts of the river would have much higher concen-trations of the tritium than other parts and thus any ingestion of t$1s i

more highly triciated water by fish, animals or even humans would result in greater irradiation of their tissues (by the beta particles) than one would anticipate by the engineering hypothesis of a totally uniform critrium f

distribution.

I e

s I

h 8

g t '

r f

i t:

r2-

^'::

~

Biological Accumulation or Concentration The toxicity of any hazardous substance is typically, a function of the quantity of that substance to which a living organism is exposed.

Radiation is no exception, the larger the concentration of the radioisotope the greater the risk of genetic and somatic damage resulting in birth defects, sti11 births and cancer. When it came to evaluating the ef f ect of tritium (T),

the International Commission of Radiological Protection (ICRP) calculated its population dose based on the tritium activity that ould equilibrate with the body fluid (i.e., the inorganic compartment) and totally neglected the covalently bound tritium (i.e., the organic compartment).

The implicit assumption of the ICRP dose estimate is that the triciated body water exchanges its tritiumfor hydrogen only in a polar or ionic transfer with other molecules.

Understandably, real life is not that simple ano there is now considerable scientific evidence demonstrating that the tritium to hydrogen ratio (TLD is much greater in the organic molecules or biopolymers (such as polysacch-arides,' lipids, proteins and nucleic acids) than in the' inorganic tritium source (HTO).

This results from at least three distinct bialogical or

, biochemical phenomena including (1) isotope effects in metabolic pathways (2) concentration of tritium within the organic compartment along a food ok i

chain and (3) radiation dausge Induction unscheduled DNA synthesis,

{

3 The metabolic route can, for example, produce covalent tritium-carbon bonds which are much stronger than the more polar hydrogen-oxygen bonds found in the inorganic compartment.

Since many of these organic biopolyaers are quite stable (i.e., long half-lives), the tritium tends to " hang around" for relatively long intervals.

The data also suggests that tritiated organic

~

recursersaremoreeasilyincorporated[thansimpleHTO)intoorganisms, r

t

+

fr.

J:

}

. z,.

further along a food chain with several trophic levels.

Thus the greater chemical stability of the tritiated organic molecules and their concentration along the for chain results in a much greater biological accumulation of tritium tu.;

one would anticipate f rom the oversimp12 fied

~

' ICRP hypothesis.

The incorporation of tritium into any biopolymer is clearly a function of the concentration of tritiated precursors, the rate of synthesis and the half-life of that macromolecule in vive.

In the specific. case of DNA, the beta decay of tritium causes radiation damage to this biopolymer which increases its rate of synthesis, that is, the tritium has an'autocatlytic effect on the synthesis of DNA.

All three phenomena therefore come into play, pr'oducing a greatly increased steady-state concentration of triciated DNA (T-DNA).

In fact, several investigators have found that the incorporation of tritium into DNA was 3 or 4 times that found in the water (HTO), clearly demonstrating

~

the importance of biologica1 ' accumulation.

O 4

4 e

O 6

i

?

.t

'Microdistribution Af fects Relative -Biological Effectiveness The radiotonicity of tritium depends, in part, on its exact tissue, cellular and molecular localization.

The marked differences in the.

p r

radiosensitivity of various tissues has been well recognized, however, l

the affect of the microdistribution of the radioisotope within the cell has only recently been demonstrated. A measure of that cellular e

radiotoxicity is called the relative biological effectiveness (RBE) or quality factor (QF) and it may be assayed in various ways such as.Ne inhibition.of erythropoiesis, killing of oocytes or spermatogonia, frequency cf dominant ' lethal mutations; tissue c,ulture growth rate (e.g., He l&.

Cells) inhibition, or the number of single strand breaks in DNA.

It appears that the toxicity of tritium varier greatly with its molecular form, f'or example, the QF of tritiated DNA(T-DNA) is larger than tritiated water (HTO) or even other organic molecules (e.g. tritiated proteins or lipids)/,

Recent studies indicate that the RBE for tritiated-DNA is closer to 4 rather than the 1.7 or 1 designated by the ICRP.

The greater RBE for tritiated-

+

DNA is consistent with the increased ieportance of DNA strand breaks and e

, chromosomal structural aberrations as being primarie.y responsible for' the mutagenic and carcinogenic effects of radiation.

In addition to its well-known capacity for rupturing the DNA strand or macromolecule, there have been at least four other mechanisms identified that tend to augment its radiotoxic potential, namely, the (1) beta radiation from tritium retards t'.=

rate and efficacy.of DNA repair (2) DNA may be altered so that point mutations are introduced by errors in the rapid mechanis'ms (3) induction o'f' repair mechanisms (by radiation damage) may also f acilitate viral trans-format'ons of the cells into abnormal or malignant forms and (4) synergistic J3

?$

a C

[

~

' ~

effects due to the presence of toxic chemicals may enhance the radiotoxic effect of the decaying tritium nuclei within the DNA.

Thus any calculation or estimate of the population dose resulting from e..posure to tritium or tritiated water must consider both the greater concentration of triciated DNA than was previously suspected as well as its much larger QF.

These two factors alone may represent a ten-fold increase in the

. radiotoxicity of tritium and must be properly reflected by new government standards for the" acceptable levels of tritium" to which the public may be subjected.

i i

Submitted by:

i Irving M. Stillman, M.D.,Ph.D Howard County Doctors Bldg.

[

9380 Baltimore National Pike f

Ellicott City, Md. 21043 t

t 1

1 I

9 g

5 l-w

-