Application for Amend 56 to License DPR-66,deleting Hydraulic Snubbers,Either Removed or Changed to Mechanical Snubbers,From App a Tech Spec Table 3.7-4.Fee Encl
ML20008E222
Person / Time
Site: Beaver Valley
Issue date: 10/17/1980
From: Dunn C
DUQUESNE LIGHT CO.
To: Varga S
Office of Nuclear Reactor Regulation
Shared Package
ML20008E223 List:
References
TAC-43063, NUDOCS 8010240432
Download: ML20008E222 (3)


Text

s

$VL

'At5 M

pu) 4ss-sooo 435 Siam Avenue gtgurgh, PennsWyania October 17, 1980 Director of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Attn:

Mr. Steven A. Varga, Chief Operations Reactors Branch No. 1 Division of Licensing Washington, D. C.

20555

Reference:

Beaver Valley Power Station, Unit No. 1 Docket No. 50-334 Request for Amendment 56 to Operating License Gentlemen:

Enclosed are three (3) signed originals and thirty-seven (37) copies of a prcposed change to the Beaver Valley Power Station Appendix A Technical Specifications.

The change is being submitted *to revise table 3.7-4 to delete hydraulic snubbers that were either removed or changed to mechanical snubbers as a result of the piping reanalysis for the Show Cause Order or the NPSH modifications.

Safety Evaluation Snubbers RS-HSS-212 and RS-HSS-228 were deleted and replaced with rigid supports dae to the piping reanalysis associated with the Show Cause Order.

Also, as a result of this reanalysis, WR-HSS-307 and CC-HSS-406A & B were replaced with mechanical snubbers.

The following snubbers were deleted and replaced with rigid supports in conjunction with the NPSH piping modifications SI-HSS-211, QS-HSS-502 and OS-HSS-503.

Additionally, QS-HSS-501 was replaced with a mechanical snubber.

We believe that these changes improve the system integrity since all modifications were analyzed and installed in accordance with the latest NRC approved criteria for Beaver Valley Power S tation.

The OSC and ORC have reviewed the

' proposed change to the Technical Specification and have de-

,termined that there are no safety implications associated with

^8 010 2 + 0'/3%--

f

Benysr Valley Pow $r Station, Unit No. 1 Dockst No. 50-334

-Request for Amendment 56 to Operating License Page 2 the change and that the change does not constitute an unreviewed safety question'.

We have determined this change to be a class III amendment and we are enclosing a check for $4,000 in accordance with 10 CFR 170.22.

I would like to request that the change be handled on an emergency basis.

The change has to be implemented prior to the plant entering Mode 4.

Very truly yours, hA/

C. N.

Dunn Vice President, Operations A ttachment cc:

Mr. D. A. Beckman, Resideltt Inspector U. S. Nuclear Regulatory Commission Beaver Valley Power Station Shippingport, PA 15077 U. S. Nuclear Regulatory Commission c/o Document Management Branch Washington, D.

C.

20555 l

(CORPOPATE SEAL)

Attest:

p-

((hM. a

/,

3 Thomas Welfer[ Jr.'

Secretary COMMONWEALTH OF PENNSYLVANIA)

) SS:

COUNTY OF ALLEGHENY On this

/7' day of 6 C Id 880 1980, before a Notary Public in and for said Commonwealth me, ppmpw gmmigy and County, personally appeared C. N. Dunn, who being. duly sworn, deposed, and said that (1) he is Vice President of Duquesne Light, (2) he is duly authorized to execute and file the foregoing Submittal on behalf of said Company, and (3) the statements set forth in the Submittal are true and correct to the best of his knowledge, information and belief.

-]

r/ /.l f*//_

4't m s- ~ w fi e v-,sr A

00NALD W. SHANNON. NOTARY PUBUC PITISSURGli, ALLEGHENY COUN1Y i

MY COMMISS:CN EXPIRES JUNE 7.1983 Member. Pennsy: vama Associat on of Nc* anes 1

L

.