Notice of Violation from Insp on 900108-12.Violation Noted: Licensee Failed to Perform Adequate Design Change for Refueling Water Storage Tank Level Transmitters & Failed to Perform Safety Evaluation,Per 10CFR50.59 for Design Change
ML20006E709
Person / Time
Site: Sequoyah  
Issue date: 02/07/1990
From: Wilson B
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20006E705 List:
References
50-327-90-01, 50-327-90-1, 50-328-90-01, 50-328-90-1, NUDOCS 9002260251
Download: ML20006E709 (2)


Text

,~

n

,g-

'w b[ 5 I

i

' ENCLOSURE 1 v

NOTICE OF VIOLATION Tennessee Valley Authority Docket Nos. 50-327, 50-328 Sequoyah Units 1 and 2 License Nos. DPR-77, DPR-79:

+

DuringEthe Nuclear Regulatory Commission' (NRC) inspection. conducted on 1

~ January 8-12, 1990, a violation of NRC. requirements was identified.

In accordance with - the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (1989), the violation is' listed q

below:

10 CFR 50, Appendix B,

Criterion III, requires that measures be established to assure that applicable regulatory requirements and the design basis for structures, systems, and components are correctly

- u translated into specifications, drawings, procedures, and instructions.

f 10 CFR 50.59 requires that safety evaluations shall be performed which provide the bases for the determination that a change, test, or experiment

-does not: involve an unreviewed safety ~ question to identify if the-probability of occurrence or the~ consequences of an accident-or malfunction of equipment important to safety previously evaluated in the-

{

/ safety analysis report may be increased.

]

4 Contrary to the above, prior to December 15, 1989' the licensee failed to-perform an adequate design change for the RWST level transmitters and '

J failed to perform an adequate safety evaluation as. required by 10 $ 7 50.59 for the same change, in that Design Change Notice M0138A l

remo-the thermostats and heaters from; the RWST level transmitters 1

withc.t considering the effects of freezing and the' associated safety j

evaluation, M0138A,- also did not consider the effects of freezing. As a result, on December 15, 1989 the RWST level transmitters froze and were i

c declared inoperable. The' heaters and thermostats were installed in 1982-J d

to provide freeze protection for these transmitters.

t.

EThis is a Severity Level IV violation (Supplement I).

Pursuant.to the provisions of 10 CFR 2.201, Tennessee Valley Authority is hereby required to submit a written statement or explanation to the Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555,

)1:

with:a copy to the~ Associate Director for Special Projects, Office of Nuclear l

a Reactor Regulation, and a copy to the NRC Resident Inspector, Sequoyah, within 30 days of-the date of the letter transmitting this Notice. This reply should J

be clearly marked as a_ " Reply to a Notice of Violation" and should include for each violation:

(1) admission or denial of the violation, (2) the reason for the violation if admitted, (3) the corrective steps which have been taken and the results' achieved, (4) the corrective steps which will be taken to avoid

.f s

k g22gg N$

h s

b

p#

y 9'-

{4 f;'

Tennessee Valley Authority 2

' Docket Nos. 50-327, 50-328 Sequoyah License Nos. DPR-77, DPR-79 i

further violations, and (5) the date when full compliance will-be achieved.

.Where good cause is.shown, consideration will be given to extending the response time. If an adequate reply is not received within the time specified in-this Notice, an' order may be-issued to show cause why.the.. license should not be modified,- suspended, or ~ revoked or why such other action as may be proper -

-should not be taken.

FOR THE NUCLEAR REGULATORY COMMISSION

['

+

Bruce Widson,As ant Director for Inspection Programs TVA Projects Division Office of Nuclear Reactor Regulation Dated at Atlanta, Georgia c

this % day of February 1990 i

1 i

.